Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biochem Biophys Res Commun ; 735: 150451, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39094233

RESUMO

Cerebral small vascular disease (CSVD) has a high incidence worldwide, but its pathological mechanisms remain poorly understood due to the lack of proper animal models. The current animal models of CSVD have several limitations such as high mortality rates and large-sized lesions, and thus it is urgent to develop new animal models of CSVD. Ultrasound can activate protoporphyrin to produce reactive oxygen species in a liquid environment. Here we delivered protoporphyrin into cerebral small vessels of rat brain through polystyrene microspheres with a diameter of 15 µm, and then performed transcranial ultrasound stimulation (TUS) on the model rats. We found that TUS did not affect the large vessels or cause large infarctions in the brain of model rats. The mortality rates were also comparable between the sham and model rats. Strikingly, TUS induced several CSVD-like phenotypes such as cerebral microinfarction, white matter injuries and impaired integrity of endothelial cells in the model rats. Additionally, these effects could be alleviated by antioxidant treatment with N-acetylcysteine (NAC). As control experiments, TUS did not lead to cerebral microinfarction in the rat brain when injected with the polystyrene microspheres not conjugated with protoporphyrin. In sum, we generated a rat model of CSVD that may be useful for the mechanistic study and drug development for CSVD.

2.
J Chromatogr A ; 1166(1-2): 201-6, 2007 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-17761187

RESUMO

A novel polydimethylsiloxane (PDMS) surface modification method for microchip electrophoresis has been developed to make a stable and sufficient electroosmotic flow (EOF). Poly(l-glutamic acid) (PGA) which had ionizable carboxyl groups at a high pH-range was immobilized on the surface of microchannel fabricated with PDMS. The surface modification involved surface oxidation by plasma, the silanization of 3-aminopropyldimethylethoxysilane (APDMES) and immobilization of PGA via amide bond. The modified channel was extremely stable against consecutive electric power supply over 5h, and its long-term stability was demonstrated by the efficient separation of four amino acid derivatives reproducibly after a week. Additionally, homocysteine (Hcy), important risk factor of cardiovascular disease, osteoporosis and problems in pregnancy, was successfully measured in human serum in modified PDMS channel with the other thio amino acid simultaneously.


Assuntos
Eletroforese em Microchip/métodos , Glutationa/sangue , Homocisteína/sangue , Dimetilpolisiloxanos/química , Eletro-Osmose , Eletroforese em Microchip/instrumentação , Humanos , Concentração de Íons de Hidrogênio , Ácido Poliglutâmico/química , Reprodutibilidade dos Testes , Silicones/química , Propriedades de Superfície
3.
J Chromatogr A ; 1216(15): 3337-42, 2009 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-19269645

RESUMO

The first version of nano-injection device for capillary gas chromatography (cGC) based on inkjet microchip was developed. The nano-injector could accurately control the injection volume in nano-liter, even pico-liter range. Its configuration and mechanism were discussed in detail. Adopting photolithography and plasma etching technology, we firstly fabricated the inkjet microchip and stuck to a piezoelectric device to eject droplets. Then, a special feedback tube was added to make it function as a nano-injector for cGC, which was an important design to compensate pressure difference between the evaporation chamber of cGC and the sample extrusion chamber of inkjet microchip. The injected volume can be precisely controlled by the number of injected droplets. Excellent precision (RSDs were below 10.0%, n=5) was observed for the injection of ethanol at elevated pressure. Minimum injection volume was about 1.25nL at present. Additionally, good repeatability of the calibration curves for the hydrocarbons ethanolic solution (the RSDs of all components were below 5.30%, n=5) confirmed its feasibility in quantitative analysis regardless of concentration. These results suggested that it can be an accurate nano-injector for cGC.


Assuntos
Cromatografia Gasosa/instrumentação , Nanotecnologia/instrumentação , Cromatografia Gasosa/métodos , Desenho de Equipamento , Etanol/química , Hidrocarbonetos/análise , Modelos Lineares , Pressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Artigo em Inglês | MEDLINE | ID: mdl-17685238

RESUMO

A chiral separation model of gel electrochromatography in a polydimethylsiloxane (PDMS) microfluidic device for amino acids (AAs) is presented. Six pairs of fluorescein isothiocyanate (FITC)-labeled dansyl amino acids (Dns-AAs) were separated in a 36-mm effectual separation channel in less than 120 sec, with resolutions all above 0.96. This highly efficient PDMS chiral microfluidic chip was prepared by inserting the mixture solution of monomers, crosslinkers, and radical initiation into the microchannel via syringe. Specifically, allyl-gamma-cyclodextrin (CD) as a chiral selector and crosslinker was bonded in gamma-CD-bonded polyacrylamide (PAA) gel, which was the separation media, and was immobilized in a PDMS microchannel through the stable linkage of 3-(trimethoxysilyl)-propyl methacrylate (Bind-Silane, Sigma, St. Louis, MO, U.S.A.). The preparation not only permitted the prompt chiral separation of AAs, but also extended application of the PDMS microfluidic device by restraining its hydrophobicity through the PAA gel monolithic column. Furthermore, the longevity of the PDMS microfluidic device was prolonged significantly. This can also be a powerful way to develop a rapid and efficient bioanalysis method and portable analytical apparatus.


Assuntos
Aminoácidos/química , Aminoácidos/isolamento & purificação , Cromatografia Líquida/métodos , Dimetilpolisiloxanos/química , Fluoresceína-5-Isotiocianato/química , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Silicones/química , Cromatografia Líquida/instrumentação , Estrutura Molecular , Estereoisomerismo , gama-Ciclodextrinas/química
5.
Electrophoresis ; 28(24): 4590-6, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18004712

RESUMO

The aqueous solution of a kind of room-temperature ionic liquids (RTILs), 1-ethyl-3-methylimidazolium-tetrafluoroborate (1E-3MI-TFB), demonstrated its exclusive electroosmotic property in microchip electrophoresis. It was applied as the working electrolyte for chiral separation in glass microchip electrophoresis. Compared with boric acid buffer, 1E-3MI-TFB aqueous solution exhibited a broader separation window for enantiomers of dipeptides. Then the influences of chiral selector, pH and concentration on efficiency of chiral separation were discussed in detail. The unique mechanism of the generation of EOF was explored in a glass microchannel using 1E-3MI-TFB aqueous solution as working electrolyte. A possible status of 1E-3MI cation in water was suggested at the first time, which facilitated the explanation of EOF and its characteristics in glass microchannel. Additionally, microchip electrophoresis using 1E-3MI-TFB aqueous solution was successfully applied to the chiral separation of complex enantiomers of dipeptides. RTILs aqueous solution, as the electrolyte for the separation of complicated optical isomers, could lead to a revolution in the analytical methods of chiral or conformational analysis for biomolecules.


Assuntos
Eletroforese em Microchip/métodos , Imidazóis/química , Soluções , Estereoisomerismo
6.
Talanta ; 69(1): 226-31, 2006 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970558

RESUMO

A beta-cyclodextrin (beta-CD)-bonded gel monolithic column polydimethylsiloxane (PDMS) microfluidic device was developed in a simple and feasible way. Before preparation of gel monolithic column in PDMS microchannel, PDMS surface was activated by UV light to create silanol groups, which is an active molecule to covalently bond 3-(trimethoxysilyl)-propyl methacrylate (Bind-Silane) and seal microfluidic device. By the way, Bind-Silane is a bifunctional molecule to link polyacrylamide (PAA) gel and inner wall of PDMS microchannel covalently. Allyl-beta-CD was used not only as a multifunctional crosslinker in PAA gel to control the size of the pores, but also as a chiral selector for the enantioseparation. The stability, transferring heat and optical characteristic of the microfluidic device were examined. The separation capability of the gel monolithic column was confirmed by the successful separation of fluorescein isothiocyanate (FITC)-labeled arginine (Arg), glutamine acid (Glu), tryptophan (Try), cysteine (Cysteine) and phenylalanine (Phe) in the PDMS microfluidic device less than 100 s at 36 mm effective separation length. A maximum of 2.06 x 10(5) theoretical plates was obtained by the potential strength of 490 V/cm. A pair of FITC-labeled dansyl-D,L-threonine (Dns-Thr) was separated absolutely.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA