1.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37906433

RESUMO

AIMS: State-of-the-art pacemaker implantation technique in infants and small children consists of pace/sense electrodes attached to the epicardium and a pulse generator in the abdominal wall with a significant rate of dysfunction during growth, mostly attributable to lead failure. In order to overcome lead-related problems, feasibility of epicardial implantation of a leadless pacemaker at the left ventricular apex in a growing animal model was studied. METHODS AND RESULTS: Ten lambs (median body weight 26.8 kg) underwent epicardial implantation of a Micra transcatheter pacing system (TPS) pacemaker (Medtronic Inc., Minneapolis, USA). Using a subxyphoid access, the Micra was introduced through a short, thick-walled tube to increase tissue contact and to prevent tilting from the epicardial surface. The Micra's proprietary delivery system was firmly pressed against the heart, while the Micra was pushed forward out of the sheath allowing the tines to stick into the left ventricular apical epimyocardium. Pacemakers were programmed to VVI 30/min mode. Pacemaker function and integrity was followed for 4 months after implantation. After implantation, median intrinsic R-wave amplitude was 5 mV [interquartile range (IQR) 2.8-7.5], and median pacing impedance was 2235 Ω (IQR 1725-2500), while the median pacing threshold was 2.13 V (IQR 1.25-2.9) at 0.24 ms. During follow-up, 6/10 animals had a significant increase in pacing threshold with loss of capture at maximum output at 0.24 ms in 2/10 animals. After 4 months, median R-wave amplitude had dropped to 2.25 mV (IQR 1.2-3.6), median pacing impedance had decreased to 595 Ω (IQR 575-645), and median pacing threshold had increased to 3.3 V (IQR 1.8-4.5) at 0.24 ms. Explantation of one device revealed deep penetration of the Micra device into the myocardium. CONCLUSION: Short-term results after epicardial implantation of the Micra TPS at the left ventricular apex in lambs were satisfying. During mid-term follow-up, however, pacing thresholds increased, resulting in loss of capture in 2/10 animals. Penetration of one device into the myocardium was of concern. The concept of epicardial leadless pacing seems very attractive, and the current shape of the Micra TPS makes the device unsuitable for epicardial placement in growing organisms.


Assuntos
Marca-Passo Artificial , Humanos , Criança , Animais , Ovinos , Resultado do Tratamento , Desenho de Equipamento , Ventrículos do Coração , Miocárdio , Estimulação Cardíaca Artificial/métodos
2.
Europace ; 24(10): 1627-1635, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35718878

RESUMO

AIMS: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. METHODS AND RESULTS: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62-141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. CONCLUSION: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência Renal Crônica , Idoso , Criança , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Lasers de Excimer , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 43(12): 1481-1485, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32896897

RESUMO

BACKGROUND: Pacemaker used in small children typically consist of an abdominally placed generator and epicardially affixed leads, making such a system prone to lead dysfunction during growth. Aim of this study was to investigate the feasibility of epicardial pacing with a leadless pacemaker in a lamb model. ANIMALS AND METHODS: Seventeen lambs underwent epicardial implantation of a Micra transcatheter pacing system (TPS) (Medtronic, Minneapolis, MN, USA) via left-lateral thoracotomy to the left ventricle (LV) surface (n = 11/17) and to the left atrial appendage (n = 6). Ventricular devices were fixated with the tines within the pericardium, whereas the tines of the atrial devices penetrated the myocardium of the left atrial appendage. After 31 weeks, animals were sacrificed and hearts were explanted for histological analysis. RESULTS: Following implantation, median P/R amplitude was 4.25/5.5 mV while median pacing threshold was 1.1/1.9 V at 0.24 ms. After 31 weeks, median P/R amplitude was 3.3/4.2 mV. Median atrial pacing threshold was 0.5/0.24 ms. Eight of 10 ventricular pacemakers had lost capture at standard impulse width even at maximum impulse amplitude. On explantation, firm adhesion of the device to the thoracic wall and dislodgement of the electrode tip was found in those ventricular devices. CONCLUSIONS: Firm fixation of the Micra electrode to the epicardial surface as applied to the atrial devices resulted in excellent electrical properties during midterm follow up. Pericardial fixation as in the ventricular devices was associated with loss of capture. Therefore, it is important to embed the tines in the myocardium and to choose an alternative implantation site allowing for safe fixation of the Micra TPS in a position perpendicular to ventricular epimyocardium.


Assuntos
Marca-Passo Artificial , Toracotomia/métodos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Modelos Animais , Pericárdio/cirurgia , Carneiro Doméstico
4.
J Vasc Surg ; 66(1): 281-297.e2, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28647036

RESUMO

OBJECTIVE: Our aim was to analyze the outcomes of endovascular exclusion of the entire aortic arch (proximal landing in zone 0, distal landing in zone III or beyond, after Ishimaru) in which complete surgical debranching of the supra-aortic vessels (I), endovascular supra-aortic revascularization (chimney, fenestrated, or branched grafts) with partial surgical debranching (II), or total endovascular supra-aortic revascularization (III) was additionally performed. METHODS: Publications describing endovascular repair of the aortic arch (2000-2016) were systematically searched and reviewed. RESULTS: From a total of 53 relevant studies including 1853 patients, only 1021 patients undergoing 35 different total aortic arch procedures were found eligible for further evaluation and included in group I, II, or III (429, 190, and 402 patients, respectively). Overall early mortality was higher in group I vs groups II and III (P = .001; 1 - ß = 95.6%) but exceeded in group III (18.6%) and group II (14.0%) vs group I (8.0%; P = .044; 1 - ß = 57.4%) for diseases involving zone 0. Mortality was higher in all subgroups treated for zone 0 disease compared with corresponding subgroups treated for zone I to zone III disease. The incidence of cerebral ischemic events was increased in groups I and II vs group III (7.5% and 11% vs 1.7%; P = .0001) and correlated with early mortality (R2 = .20; P = .033). The incidence of type II endoleaks and endovascular reintervention was similar between groups and correlated with each other (R2 = .37; P = .004). Type Ia endoleak occurred more often in groups II and III than in group I (7.1% and 12.1% vs 5.8%; P = .023) and correlated with midterm mortality (R2 = .53; P = .005). Retrograde type A dissection was low in all groups, whereas aneurysm growth was higher in group III (2.6%, 4.2%, 10.7%; P = .002), correlating with midterm mortality (R2 = .311; P = .009). Surgical revision slightly correlated with surgical complications (R2 = .18; P = .044) but not with mortality (R2 = .10; P = .214). CONCLUSIONS: Because early mortality was significantly higher in patients receiving endovascular treatment for proximal aortic disease, endovascular-based approaches proved to be feasible alternatives to hybrid surgical procedures, especially when they were performed for aneurysms located in the distal aortic arch. Whereas cerebral ischemia accompanies both surgical and endovascular involvement of the supra-aortic vessels, endoleaks and aneurysm growth remain hallmarks of endovascular supra-aortic repair. Because surgical revision had no impact on mortality, complete surgical debranching may become the option of choice for patients with good life expectancy suffering from proximal aortic arch disease, whereas total endovascular procedures could be particularly advantageous in patients with short life expectancy and distal aortic arch disease.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Desenho de Prótese , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
5.
Europace ; 16(2): 258-64, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23813451

RESUMO

AIMS: To evaluate passive-fixation lead failure rates and long-term patient survival in subjects implanted with Sprint Fidelis electrodes. METHODS AND RESULTS: We identified 748 subjects who received a Sprint Fidelis (n = 429; Medtronic models 6948: 94.8%, 6949: 2.6%, 6930: 1.9%, 6931: 0.7%) or a Sprint 'non-Fidelis' implantable cardioverter defibrillator lead (n = 319, Medtronic models 6944: 68.6%, 6947: 17.9%, 6942: 7.8%, 6943: 3.4%, 6945: 2.2%) at our centre between 1998 and 2008. Kaplan-Meier patient survival was lower in the Fidelis group than in the Control cohort (68.4 vs. 77.0% at 5 years, P = 0.0061), but multivariate analyses revealed no significant association between mortality and implanted lead type. Passive-fixation lead failure rate at 5 years was 14.4% (95% confidence interval (CI) [9.2, 19.3]) in the Fidelis (n = 414) group and 1.8% (95% CI [0.0-3.8]) in the Control (n = 241) cohort (P < 0.001 upon multivariate comparison). CONCLUSION: Failure rates of passive-fixation Sprint Fidelis leads are increased and similar to those previously reported for active-fixation Fidelis electrodes. Despite the elevated risk for lead failure and its potential sequelae, the Sprint Fidelis has no obvious impact on long-term mortality.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Falha de Prótese , Idoso , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Alemanha , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 35(4): e105-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21745225

RESUMO

We describe a case of 83-year-old man who was admitted to our department for treatment of recurrent device-pocket infections. Our report shows that in a case of high-risk patient with a complicated cardiac implantable electric devices infection involving multidrug-resistent gram-positive pathogen, the application of daptomycin in combination with staged surgical therapy can be efficient and safe.


Assuntos
Antibacterianos/uso terapêutico , Daptomicina/uso terapêutico , Desfibriladores Implantáveis/microbiologia , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus haemolyticus/efeitos dos fármacos , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Resistência a Múltiplos Medicamentos/efeitos dos fármacos , Humanos , Masculino , Infecções Estafilocócicas/diagnóstico , Resultado do Tratamento
7.
Europace ; 13(7): 1004-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21454336

RESUMO

AIMS: A growing number of patients with implanted rhythm devices require new or additional leads, e.g. in cases of electrode defect or planned device upgrade. If the ipsilateral subclavian vein is occluded, transvenous electrode placement from the contralateral side with subcutaneous, pre-sternal lead tunnelling (TUN) is one potential option that has been described in anecdotal reports. The aim of this retrospective study was to determine the acute and long-term feasibility of this approach. METHODS AND RESULTS: We identified 18 subjects (67% male, 66±14 years) who underwent TUN at our institution between the years 1995 and 2009. Implantation protocols and patient files were reviewed for peri-operative complications and long-term lead performance. Furthermore, patients were interviewed for symptoms related to the tunnelled lead. Twenty transvenous leads (seven implantable cardioverter defibrillator leads; five left ventricular, four right ventricular, four right atrial pace/sense electrodes) were successfully tunnelled without significant peri-operative complications. The follow-up duration was 29±36 (3-162) months. Electrical parameters remained stable in 95% (19/20) of the tunnelled leads. In one right ventricle pace/sense lead, ventricular oversensing was documented 10 months after TUN, and the lead was replaced because a structural defect could not be excluded. Five patients died without causal relationship to the procedure 4-48 months after TUN. One patient reported discomfort related to the tunnelled lead. CONCLUSION: Contralateral transvenous lead implantation with subcutaneous, pre-sternal TUN appears to be a feasible option in selected patients with an implanted rhythm device and ipsilateral subclavian vein occlusion.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Eletrodos Implantados , Idoso , Idoso de 80 Anos ou mais , Tubos Torácicos , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Veia Subclávia , Fatores de Tempo , Falha de Tratamento , Resultado do Tratamento
8.
Artif Organs ; 34(11): 1061-5, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21092049

RESUMO

Friedreich's ataxia (FRA) is an autosomal recessive disease of the central nervous system that is associated with familial cardiomyopathy. Cardiac involvement is seen in more than 90% of the patients and is the most common cause of death in these patients. We present a case series and discuss the indications for implantable cardioverter defibrillator (ICD) implantation in FRA with review of the literature. Five pediatric patients who suffer from FRA (four female and one male, mean age 17.4 years) underwent ICD implantation between 2007 and 2008 in the University Hospital of Goettingen. The diagnosis of FRA was established by standard clinical criteria and proven in each case by genotyping at the frataxin locus. The time from diagnosis to ICD implantation was 10.4±1.73 years (range 8-15 years). All patients received transvenous lead systems. There were no intraoperative and postoperative complications. At the latest follow-up, the neuromuscular symptoms exhibited no further progress and no ICD activations were noticed. Only minor repolarization changes were seen on electrocardiogram. All patients had normal echocardiographic findings and no angina has been reported. Coronary angiographies were normal. It is evident that many FRA patients develop ventricular dysfunction. In the absence of a definitive surgical cure an ICD is generally indicated in young patients with hemodynamically significant sustained ventricular tachyarrhythmias for prevention of sudden cardiac death. Our experience implies the safe use of ICD in children with FRA.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Ataxia de Friedreich/complicações , Taquicardia Ventricular/prevenção & controle , Adolescente , Adulto , Angiografia Coronária , Morte Súbita Cardíaca/etiologia , Ecocardiografia , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Adulto Jovem
9.
Cardiol Young ; 20(4): 396-401, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20456817

RESUMO

OBJECTIVE: Correction of tetralogy of Fallot has excellent long-term results. The present retrospective study investigates the indications for reoperation late after corrective surgery. METHODS: Data from 914 consecutive cases who underwent correction of tetralogy of Fallot in our department between 1960 and 2002 were retrospectively reviewed and analysed. In 91 patients, a total of 102 reoperations were performed late after repair. RESULTS: The mean time interval between corrective surgery and the first reoperation was 12.8 years. The main indication for reoperation was residual ventricular septal defect in nearly half of the cases, mostly isolated, but also in combination with a right ventricular outflow tract aneurysm or pulmonary stenosis. One-fourth of reoperated patients underwent a procedure on their pulmonary artery or pulmonary valve: replacement of pulmonary valve, replacement of primary implanted pulmonary artery conduits with or without concomitant surgery, and surgery for isolated peripheral pulmonary stenosis. The remaining indications were right ventricular outflow tract aneurysms and others. Aneurysms of the right ventricular outflow tract were seen mostly after the use of autologous - untreated - pericardial patch in 18 of 21 cases. CONCLUSION: The number of reoperations for residual ventricular septal defect decreased during the study period. The primary use of conduits led to an increased number of reoperations for conduit exchange due to degeneration or failure. Use of an untreated autologous pericardial patch for enlargement of the right ventricular outflow tract should be avoided due to increased risk for aneurysm formation.


Assuntos
Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Masculino , Seleção de Pacientes , Reoperação , Estudos Retrospectivos , Fatores de Risco , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico , Fatores de Tempo , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adulto Jovem
10.
Eur J Heart Fail ; 11(3): 273-80, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19147446

RESUMO

AIMS: The combined therapeutic impact of atrial overdrive pacing (AOP) and cardiac resynchronization therapy (CRT) on central sleep apnoea (CSA) in chronic heart failure (CHF) so far has not been investigated. We aimed to evaluate the effect of CRT alone and CRT + AOP on CSA in CHF patients and to compare the influence of CRT on CHF between CSA positive and CSA negative patients. METHODS AND RESULTS: Thirty patients with CRT indication underwent full night polysomnography, echocardiography, exercise testing, and neurohumoral evaluation before and 3 months after CRT implantation. In CSA positive patients (60%), two additional sleep studies were conducted after 3 months of CRT, with CRT alone or CRT + AOP, in random order. Cardiac resynchronization therapy resulted in significant improvements of NYHA class, left ventricular ejection fraction, N-terminal pro-brain natriuretic peptide, VO(2)max, and quality of life irrespective of the presence of CSA. Cardiac resynchronization therapy also reduced the central apnoea-hypopnoea index (AHI) (33.6 +/- 14.3 vs. 23.8 +/- 16.9 h(-1); P < 0.01) and central apnoea index (17.3 +/- 14.1 vs. 10.9 +/- 13.9 h(-1); P < 0.01) without altering sleep stages. Cardiac resynchronization therapy with atrial overdrive pacing resulted in a small but significant additional decrease of the central AHI (23.8 +/- 16.9 vs. 21.5 +/- 16.9 h(-1); P < 0.01). CONCLUSION: In this study, CRT significantly improved CSA without altering sleep stages. Cardiac resynchronization therapy with atrial overdrive pacing resulted in a significant but minor additional improvement of CSA. Positive effects of CRT were irrespective of the presence of CSA.


Assuntos
Estimulação Cardíaca Artificial/métodos , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/complicações , Apneia do Sono Tipo Central/terapia , Idoso , Função Atrial/fisiologia , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Polissonografia , Método Simples-Cego , Apneia do Sono Tipo Central/etiologia , Apneia do Sono Tipo Central/fisiopatologia , Resultado do Tratamento
12.
Int J Vasc Med ; 2018: 7205903, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30186634

RESUMO

OBJECTIVE: Carotid artery stenosis in patients undergoing open-heart surgery may increase risk and deteriorate outcome. The aim of the study was the analysis of risks and outcome after simultaneous carotid and cardiac surgery. METHODS: We retrospectively reviewed the medical records of 100 consecutive patients who underwent simultaneous carotid surgery and open-heart surgery during a 5-year period (from 2006 to 2010). Seventy patients were male and 30 female; the mean age was 70.9±7.9 years (median: 71.8 years). Seventy-three patients underwent coronary bypass grafting (CABG), 18 patients combined CABG and valve procedures, 7 patients CABG combined with other procedures, and 3 patients isolated valve surgery. More than half of patients had had bilateral carotid artery pathology (n=51) including contralateral carotid artery occlusion in 12 cases. RESULTS: Carotid artery patch plasty was performed in 71 patients and eversion technique in 29. In 75 cases an intraluminal shunt was used. Thirty-day mortality rate was 7% due to cardiac complications (n=5), metabolic disturbance (n=1), and diffuse cerebral embolism (n=1). There were no carotid surgery-related deaths. Postoperatively, transient cerebral ischemia occurred in one patient and stroke with mild permanent neurological deficit (Rankin level 2) in another patient. CONCLUSION: Simultaneous carotid artery surgery and open-heart surgery have low risk. The underlying cardiac disease influences outcome.

13.
Medicine (Baltimore) ; 97(40): e12449, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30290602

RESUMO

The prosthetic surgical above-knee bypass (pAKB) is a standard therapy in superficial femoral artery (SFA) occlusive disease in absence of suitable vein. Viabahn graft has been established as a promising alternative. Since limited comparative data are available, we conducted a retrospective study to compare long-term outcomes of these 2 therapies in a real-world setting.Records of 52 patients (60 limbs), who were treated by pAKB (29 limbs) or Viabahn (31 limbs) were reviewed. Patients were followed up by clinical assessment, physical examination, and resting ankle brachial index (ABI) after 3, 6, 12 months and yearly thereafter. Long-term data were available for 97% in the Viabahn and 93% for pAKB after 73 ±â€Š3.7 months (mean ±â€Šstandard error [SE]).Long-term primary and secondary patencies in Viabahn group were 40% and 70%, respectively, after 63 ±â€Š2.8 months (mean ±â€ŠSE). Total lesion length was 19 ±â€Š11.06 cm (mean ±â€ŠSE), graft size was 6 ±â€Š0.72 mm (mean ±â€ŠSE). Hospital stay was 4.8 ±â€Š0.72 days (mean ±â€ŠSE). Limb salvage was achieved in 90%. Patients in the pAKB group showed a total lesion length of 24.39 ±â€Š1.97 cm (mean ±â€ŠSE), graft size was 7 ±â€Š0.99 mm (mean ±â€ŠSE). Long-term analysis after 83 ±â€Š6.8 months (mean ±â€ŠSE) revealed a primary patency of 78% with a secondary patency of 94%. Hospital stay was 10.4 ±â€Š1.27 days (mean ±â€ŠSE). Limb salvage was ensured in 97%. Long-term primary patency was lower for Viabahn (P = .044), secondary patency (P = .245), and leg salvage (P = .389) were not significantly different. However, hospital stay was shorter (P = .0002) for Viabahn.Long-term analysis of Viabahn revealed a significantly lower primary patency, a similar secondary patency, limb salvage, and significantly shorter hospital stay when compared with pAKB. Our data suggest that pAKB is still a valuable option in patients suitable for an open operation. However, Viabahn can be used as a less invasive treatment in high risk patients.


Assuntos
Implante de Prótese Vascular/métodos , Prótese Vascular , Artéria Femoral/cirurgia , Doença Arterial Periférica/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Joelho , Salvamento de Membro/métodos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
14.
J Hypertens ; 36(8): 1762-1769, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29677053

RESUMO

OBJECTIVE: Unlike safety data of baroreflex activation therapy device (Rheos), only few data of the currently used second device (Barostim neo) are available and little is reported about common side effects. METHODS: We prospectively analyzed patients with resistant hypertension treated with Barostim neo. A standardized interview regarding side effects of the therapy was performed in routine follow-up visits after device implantation in 42 patients to determine adverse events staged into three degrees. RESULTS: Within 6 months of baroreflex activation therapy, the office mean arterial blood pressure decreased from 169 ±â€Š27 to 148 ±â€Š29 mmHg systolic (P < 0.001), respectively, to 145 ±â€Š24 mmHg after 1 year (P < 0.001), whereas the number of prescribed antihypertensive classes decreased from 6.6 ±â€Š1.5 to 5.6 ±â€Š1.8 (P < 0.001). Adverse events were combination of the following field depending on the severity (I° mild: local discomfort, clinical observation only, no intervention indicated; II° moderate: medically significant such as occurrence of hypertensive crisis, syncope, arrhythmias; III° severe: life-threatening events or urgent medical intervention indicated). Adverse events I° were present in almost all patients (97.6%), and occurred mainly within first 6 months after device activation. Device-related events were most frequently and could be resolved by optimization of device parameters. Most procedure-related adverse events were directly related to the incision or anesthetic procedure. Adverse events II° occurred in 28.6% patients treated with Barostim neo, whereas patients' elevated individual risks might be potential triggers. Because of individual diversity of blood pressure response and the occurrence of adverse events, no standardization of parameters of implantable pulse generator could be found. By adapting the pulse generator settings individually, most of adverse events I° resolved without sequel. CONCLUSION: Though there are common side effects, Barostim neo significantly lowers blood pressure in resistant hypertension and provides an adequate safety profile. Regular patient visits are necessary to register side effects.


Assuntos
Pressão Arterial , Barorreflexo/fisiologia , Terapia por Estimulação Elétrica/efeitos adversos , Terapia por Estimulação Elétrica/instrumentação , Hipertensão/terapia , Idoso , Anti-Hipertensivos/uso terapêutico , Eletrodos Implantados/efeitos adversos , Feminino , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sístole
15.
Eur J Heart Fail ; 9(6-7): 716-22, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17462948

RESUMO

BACKGROUND: An alert algorithm, based on intrathoracic impedance monitoring, has been incorporated into a cardiac resynchronisation device (CRT) to detect pulmonary fluid accumulation, and to audibly alert patients to decompensating chronic heart failure (CHF). AIMS: To evaluate this algorithm, alert events were correlated with changes in NT-proBNP concentration and CHF status. METHODS AND RESULTS: In a prospective observational study of 62 patients (89% male, aged 67+/-1 year), NT-proBNP plasma concentrations, clinical CHF status, and device data were collected at enrolment, during regular follow-up and at device alerts. Over a mean follow-up of 27+/-2 weeks, pooled data indicated a weak, but significant inverse relationship between relative changes in intrathoracic impedance and NT-proBNP (r=-0.3; p<0.001). In 52 device alerts from 35 patients, NT-proBNP increased by 66+/-19% from 2039+/-331 pg/ml (p<0.001). The increase in NT-proBNP was higher in alerts with clinical signs of CHF deterioration (n=30, 89+/-25%; p<0.001) than in alert events without clinical signs (n=22, 25+/-15%; p=n.s.). CONCLUSION: Intrathoracic impedance based alert events are associated with a significant increase in NT-proBNP concentration. These data indicate that intrathoracic impedance monitoring might facilitate the outpatient management of CHF patients with implanted CRT devices.


Assuntos
Cardiografia de Impedância/instrumentação , Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Monitorização Ambulatorial/instrumentação , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Idoso , Algoritmos , Doença Crônica , Progressão da Doença , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/sangue , Humanos , Masculino , Monitorização Fisiológica , Software
17.
J Hypertens ; 34(8): 1630-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27137174

RESUMO

BACKGROUND: Both baroreflex activation therapy (BAT) and renal denervation modulate sympathetic activity. The aim of this study was to systematically investigate whether additive modulation of autonomic nervous system by BAT lowers blood pressure (BP) in patients who still suffer from uncontrolled resistant hypertension despite prior renal denervation. METHODS: From 2012 to January 2015, patients treated with BAT for uncontrolled resistant hypertension, who prior received renal denervation were consecutively analyzed in four German centers for hypertension. Analyses of office BP, 24-h ambulatory BP, central hemodynamics, parameters of renal function were performed. RESULTS: A total of 28 patients, who underwent renal denervation at least 5 months before and still suffer from uncontrolled BP, were subsequently treated with BAT. The office SBP decreased from 182 ±â€Š28 to 163 ±â€Š27 mmHg (P < 0.01) with a responder rate of 68% (office SBP reduction ≥10 mmHg) at month 6, whereas the number of prescribed antihypertensive drug classes remained unchanged (6.2 ±â€Š1.5 vs. 6.0 ±â€Š1.7, P = 0.30). Serum creatinine, estimated glomerular filtration rate and cystatin C remained stable (P = 1.00, P = 0.41 and P = 0.22, respectively), whereas albuminuria was significantly reduced by a median of -29% (P = 0.02). Central SBP (-15 ±â€Š24 mmHg, P = 0.047) and end systolic pressure (-14 ±â€Š20 mmHg, P = 0.03) were significantly reduced. CONCLUSION: The present data demonstrate that BAT may exert BP-lowering as well as antiproteinuric effects in patients with prior renal denervation. However, precise evaluation of BAT effects in patients with prior renal denervation will need randomized controlled trials using sham procedures.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Barorreflexo/fisiologia , Pressão Sanguínea , Vasoespasmo Coronário/fisiopatologia , Vasoespasmo Coronário/terapia , Hipertensão/fisiopatologia , Hipertensão/terapia , Idoso , Albuminúria/terapia , Albuminúria/urina , Anti-Hipertensivos/uso terapêutico , Creatinina/sangue , Cistatina C/sangue , Denervação , Feminino , Taxa de Filtração Glomerular , Humanos , Rim/inervação , Masculino , Pessoa de Meia-Idade , Sístole
18.
Int J Cardiol ; 98(1): 57-9, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15676167

RESUMO

BACKGROUND: Congenital coronary artery fistulas, a subgroup of anomalies of the coronary arteries, are an extremely rare cardiac defect. Most patients are asymptomatic, and if symptoms are presented, they depend on the underlying anatomy. Knowledge of those fistulas is important for prognosis and management. METHODS: Thirteen adult patients with congenital coronary fistulas (8 male, 5 female) were operated in our department during the last decade (1990-1999). Mean age was 61.5+/-10.8 years. Diagnosis was made by coronary angiography, and 15 congenital coronary artery fistulas were found. RESULTS: All patients were symptomatic with clinical symptoms depending on the associated cardiac disorder. Coronary artery fistulas originated from the proximal left descending artery (n=10), left main stem (n=3), circumflex artery (n=1), right coronary artery (n=1), and drained into the main pulmonary artery (n=14) and left ventricle (n=1). Nine fistulas (60%) were interrupted on the outside of the heart, and six fistulas (40%) were closed through the opened pulmonary artery. There was no surgical death and no fistula-related complication. CONCLUSIONS: Surgical closure of congenital coronary artery fistulas in adults can be performed with a very low risk, and closure is recommended to prevent complications.


Assuntos
Fístula Artério-Arterial/congênito , Fístula Artério-Arterial/cirurgia , Doença da Artéria Coronariana/congênito , Doença da Artéria Coronariana/cirurgia , Adulto , Idoso , Fístula Artério-Arterial/diagnóstico , Ponte Cardiopulmonar , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/cirurgia , Ecocardiografia , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Análise de Sobrevida , Toracotomia , Resultado do Tratamento
19.
Am Heart J ; 146(6): 1066-70, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14661000

RESUMO

BACKGROUND: Pacing leads with a small electrode surface for high-impedance stimulation have been shown to prolong pacemaker longevity, but no sufficient data is available on the safety and feasibility of a defibrillation lead with this novel design. METHODS: We evaluated the clinical performance of a tined, steroid-eluting defibrillation lead with a small electrode surface area (model 6944) in a prospective multicenter study. A total of 542 patients with conventional indications for an implantable cardioverter defibrillator were randomized 1:1 to receive either the model 6944 or a tined, steroid-eluting defibrillation lead with a conventional sized electrode surface area (model 6942). Device performance and electrical parameters were evaluated at implant and 1, 3, 6, and 12 months thereafter (mean follow-up 11.3 +/- 5.6 months). RESULTS: Baseline characteristics, lead implant success rates, and defibrillation thresholds did not differ significantly between the 2 groups. While pacing thresholds did not differ significantly during follow-up, pacing impedance was approximately twice as high in the model 6944 as in the model 6942 lead (P <.0001). Mean R-wave amplitudes were smaller in patients with a 6944 (9.1 +/- 3.1 mV vs 9.8 +/- 3.6 mV for model 6942, P <.05), but remained stable within both groups throughout the observation period. The total number of ventricular lead-related adverse events and patient survival did not differ significantly between the 2 groups. CONCLUSIONS: The use of a defibrillation lead with a small electrode surface for high-efficiency pacing is safe and feasible and increases pacing impedance without significantly compromising clinical performance.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Cardiopatias/terapia , Idoso , Canadá , Impedância Elétrica , Desenho de Equipamento , Falha de Equipamento , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Estados Unidos
20.
Eur J Cardiothorac Surg ; 24(6): 1037-9, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14643832

RESUMO

We describe a 71-year-old woman with spontaneous rupture of the left pulmonary artery. She was admitted with pulselessness of her left arm and lack of sensibility in her left arm and leg. Echocardiography and thoracic CT did not confirm aortic dissection. CT only showed hematoma around the descending aorta. She underwent left-sided thoracotomy. Intraoperatively, a rupture of the left pulmonary artery without any evidence of an aneurysm was found. Potentially predisposing factors for this rupture were long-term use of steroids due to COPD and her age.


Assuntos
Glucocorticoides/efeitos adversos , Prednisona/efeitos adversos , Artéria Pulmonar/efeitos dos fármacos , Doenças Vasculares/induzido quimicamente , Idoso , Dissecção Aórtica/diagnóstico , Aneurisma Aórtico/diagnóstico , Diagnóstico Diferencial , Evolução Fatal , Feminino , Humanos , Ruptura Espontânea/induzido quimicamente