Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nat Methods ; 21(4): 609-618, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443507

RESUMO

Precise identification and quantification of amino acids is crucial for many biological applications. Here we report a copper(II)-functionalized Mycobacterium smegmatis porin A (MspA) nanopore with the N91H substitution, which enables direct identification of all 20 proteinogenic amino acids when combined with a machine-learning algorithm. The validation accuracy reaches 99.1%, with 30.9% signal recovery. The feasibility of ultrasensitive quantification of amino acids was also demonstrated at the nanomolar range. Furthermore, the capability of this system for real-time analyses of two representative post-translational modifications (PTMs), one unnatural amino acid and ten synthetic peptides using exopeptidases, including clinically relevant peptides associated with Alzheimer's disease and cancer neoantigens, was demonstrated. Notably, our strategy successfully distinguishes peptides with only one amino acid difference from the hydrolysate and provides the possibility to infer the peptide sequence.


Assuntos
Nanoporos , Aminoácidos/química , Peptídeos/química , Sequência de Aminoácidos , Porinas/química , Porinas/metabolismo
2.
Medicine (Baltimore) ; 103(3): e36950, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38241561

RESUMO

INTRODUCTION: We found the G132R heterozygous mutation of thyroid stimulating hormone receptor (TSHR) gene in a patient with recurrent hypokalemia. Because the patient had a medical history of hyperthyroidism, the mutation was suspected to be related to hyperthyroidism at first. Subsequently, the expression and function studies in vitro were conducted. METHODS: Wide-type TSHR and mutant TSHR (mutTSHR) were constructed in the phage vector and pEGFP-C1 vector. After transfection, the samples were collected for detection of mRNA level, protein expression, cell activity and cAMP content. RESULTS: Compared with the wild-type TSHR, the mRNA level of the mutTSHR was not significantly different. But the protein expression, cell activity and cAMP content of the mutTSHR were significantly lower. So this indicated that the G132R mutation is a loss-of-function mutation. CONCLUSION: We identified the G132R monoallelic heterozygous mutation of TSHR gene in a patient with hyperthyroidism. Based on disease history of the patient, we speculated that the heterozygous mutation did not cause thyroid dysplasia or hypothyroidism for her. Our study enriched experiment content in vitro studies and clinical phenotype about the G132R mutation in TSHR gene.


Assuntos
Hipertireoidismo , Hipotireoidismo , Humanos , Feminino , Receptores da Tireotropina/genética , Hipertireoidismo/genética , Mutação , Hipotireoidismo/complicações , Receptores Acoplados a Proteínas G/genética , RNA Mensageiro
3.
Nanoscale ; 16(12): 6087-6094, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38444242

RESUMO

Membrane proteins are vital resources for developing biosensors. TMEM120A is a membrane protein associated with human pain transmission and lipid metabolism, and recent studies have demonstrated its ability to transport ions and bind to coenzyme A (COA-SH), indicating its potential to develop into a single-molecule sensor based on electrical methods. In this study, we investigated the ion transport properties of TMEM120A and its homolog TMEM120B on an artificial lipid bilayer using single-channel recording. The results demonstrate that both proteins can fuse into the lipid bilayer and generate stable ion currents under a bias voltage. Based on the stable ion transport capabilities of TMEM120A and TMEM120B, as well as the feature of TMEM120A binding with COA-SH, we developed these two proteins into a single-molecule sensor for detecting COA-SH and structurally similar molecules. We found that both COA-SH and ATP can reversibly bind to single TMEM120A and TMEM120B proteins embedded in the lipid bilayer and temporarily block ion currents during the binding process. By analyzing the current blocking signal, COA-SH and ATP can be identified at the single-molecule level. In conclusion, our work has provided two single-molecule biosensors for detecting COA-SH and ATP, offering insights for exploring and developing bio-inspired small molecule sensors.


Assuntos
Bicamadas Lipídicas , Proteínas de Membrana , Humanos , Bicamadas Lipídicas/química , Proteínas de Membrana/metabolismo , Coenzima A , Nanotecnologia , Trifosfato de Adenosina
4.
ACS Nano ; 18(12): 9137-9149, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38470845

RESUMO

Point-of-care monitoring of small molecules in biofluids is crucial for clinical diagnosis and treatment. However, the inherent low degree of recognition of small molecules and the complex composition of biofluids present significant obstacles for current detection technologies. Although nanopore sensing excels in the analysis of small molecules, the direct detection of small molecules in complex biofluids remains a challenge. In this study, we present a method for sensing the small molecule drug gentamicin in whole blood based on the mechanosensitive channel of small conductance in Pseudomonas aeruginosa (PaMscS) nanopore. PaMscS can directly detect gentamicin and distinguish its main components with only a monomethyl difference. The 'molecular sieve' structure of PaMscS enables the direct measurement of gentamicin in human whole blood within 10 min. Furthermore, a continuous monitoring device constructed based on PaMscS achieved continuous monitoring of gentamicin in live rats for approximately 2.5 h without blood consumption, while the drug components can be analyzed in situ. This approach enables rapid and convenient drug monitoring with single-molecule level resolution, which can significantly lower the threshold for drug concentration monitoring and promote more efficient drug use. Moreover, this work also lays the foundation for the future development of continuous monitoring technology with single-molecule level resolution in the living body.


Assuntos
Antibacterianos , Nanoporos , Humanos , Ratos , Animais , Antibacterianos/farmacologia , Gentamicinas , Nanotecnologia , Pseudomonas aeruginosa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA