1.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37936325

RESUMO

AIMS: Transvenous lead extraction (TLE) is important in the management of cardiac implantable electronic devices but carries risk. It is most commonly completed from the superior access, often with 'bail-out' support via the femoral approach. Superior and inferior access may be used in tandem, which has been proposed as an advance in safety and efficacy. The aim of this study is to evaluate the safety and efficacy of the Tandem approach. METHOD: The 'Tandem' procedure entailed grasping of the targeted lead in the right atrium to provide countertraction as a rotational dissecting sheath was advanced over the lead from the subclavian access. Consecutive 'Tandem' procedures performed by a single operator between December 2020 and March 2023 in a single large-volume TLE centre were included and compared with the conventional superior approach (control) using 1:1 propensity score matching; patients were statistically matched for demographics. RESULTS: The Tandem in comparison with the conventional approach extracted leads of much greater dwell time (148.9 ± 79 vs. 108.6 ± 77 months, P < 0.01) in a shorter procedure duration (96 ± 36 vs. 127 ± 67 min, P < 0.01) but requiring more fluoroscopy (16.4 ± 10.9 vs. 10.8 ± 14.9 min, P < 0.01). The Tandem and control groups had similar clinical (100% vs. 94.7%, P = 0.07) and complete (94.8% vs. 92.8%, P = 0.42) success, with comparable minor (4% vs. 6.7%, P = 0.72) and major (0% vs. 4%, P = 0.25) complications; procedural (0% vs. 1.3%, P = 1) and 30-day (1.3% vs. 4%, P = 0.62) mortality were also similar. CONCLUSION: The Tandem procedure is as safe and effective as the conventional TLE. It can be applied to leads of a long dwell time with a potentially shorter procedure duration.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Fatores de Tempo , Fluoroscopia , Resultado do Tratamento , Estudos Retrospectivos
2.
J Cardiovasc Electrophysiol ; 33(6): 1262-1271, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35524414

RESUMO

AIMS: To investigate the abnormalities of the coronary venous system in candidates for cardiac resynchronization therapy (CRT) and describe methods for circumventing the resulting difficulties. METHODS: From four implanting institutes, data of all CRT implants between October 2008 and October 2020 were screened for abnormal cardiac venous anatomy, defined as an anatomical variation not conforming to the accepted 'normal' anatomy. Patient demographics, procedural detail, and subsequent left ventricle (LV) lead pacing indices were collected. RESULTS: From a total of 3548 CRT implants, 15 (0.42%) patients (80% male) of 72.2 ± 10.6 years in age with an LV ejection fraction of 34 ± 10.3% were identified to have had an abnormal cardiac venous anatomy over the study period. There were 13 cases of persistent left side superior vena cava (pLSVC), five of which had coronary sinus ostium atresia (CSOA) including two with an "unroofed" coronary sinus (CS); one patient had a unique anomalous origin of the CS and one patient had an isolated CSOA. In total 14 patients (60% repeat attempt) had successful percutaneous implant under general anesthesia (46.7%) via the cephalic vein (59.1%), using the femoral approach (53.3%) for levophase venography and/or pull-through, including one case of endocardial LV implant. Pacing follow-up over 37.64 ± 37.6 months demonstrated LV lead threshold between 0.62 and 2.9 volts (pulsewidth 0.4-1.5 ms) in all cases; five patients died within 2.92 ± 1.6 years of a successful implant. CONCLUSION: CRT devices can be implanted percutaneously even in the presence of substantial abnormalities of coronary venous anatomy. Alternative routes of venous access may be required.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Veia Cava Superior Esquerda Persistente , Malformações Vasculares , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Drenagem , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Veia Cava Superior/anormalidades , Veia Cava Superior/diagnóstico por imagem
3.
J Cardiovasc Electrophysiol ; 33(1): 102-108, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34783107

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is rising in parallel to cardiac implantable electronic device implantations. Persistent left side superior vena cava (PLSVC) is a relatively common anatomical variant in the healthy population; TLE in patients with a PLSVC is rare. METHOD: Data were collated from 6 European TLE institutes of 10 patients who had undergone lead extraction with a PLSVC. Patient demographics, procedural challenges and outcomes were reported. RESULTS: Ten patients aged 73.4 ± 7.8 years (60% male) underwent TLE of 20 leads (3 left ventricle, 10 right ventricle, 7 right atrium) with dwell time of 82.95 ± 39.1 months. Of the 10 cases, 4 had an infection indication and 5 were biventricular system extractions; 25% of the extracted leads were defibrillator leads. The majority of the procedures were completed in the cardiac catheterization suite (80%) under general anaesthesia (60%) by cardiologists (80%) using a rotational powered sheath (65%). The Tandem approach was used successfully in 3 cases. Complete procedural success was obtained in 100% of cases in the absence of complications within 127.4 ± 74.7 min. There was no 30-day mortality. CONCLUSION: TLE in PLSVC is feasible albeit rare. Standard extraction techniques in experienced hands are associated with favorable outcomes; the Tandem procedure may be an additional technique to improve the safety and efficacy of TLE in PLSVC.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Veia Cava Superior Esquerda Persistente , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
4.
J Cardiovasc Electrophysiol ; 33(12): 2546-2557, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36284450

RESUMO

INTRODUCTION: The IMPACT study established the role of controlled esophageal cooling in preventing esophageal thermal injury during radiofrequency (RF) ablation for atrial fibrillation (AF). The effect of esophageal cooling on ablation lesion delivery and procedural and patient outcomes had not been previously studied. The objective was to determine the effect of esophageal cooling on the formation of RF lesions, the ability to achieve procedural endpoints, and clinical outcomes. METHODS: Participants in the IMPACT trial underwent AF ablation guided by Ablation Index (30 W at 350-400 AI posteriorly, 40 W at ≥450 AI anteriorly). A blinded 1:1 randomization assigned patients to the use of the ensoETM® device to keep esophageal temperature at 4°C during ablation or standard practice using a single-sensor temperature probe. Ablation parameters and clinical outcomes were analyzed. RESULTS: Procedural data from 188 patients were analyzed. Procedure and fluoroscopy times were similar, and all pulmonary veins were isolated. First-pass pulmonary vein isolation and reconnection at the end of the waiting period were similar in both randomized groups (51/64 vs. 51/68; p = 0.54 and 5/64 vs. 7/68; p = 0.76, respectively). Posterior wall isolation was also similar: 24/33 versus 27/38; p = 0.88. Ablation effect on tissue, measured in impedance drop, was no different between the two randomized groups: 8.6Ω (IQR: 6-11.8) versus 8.76Ω (IQR: 6-12.2; p = 0.25). Arrhythmia recurrence was similar after 12 months (21.1% vs. 24.1%; 95% CI: 0.38-1.84; HR: 0.83; p = 0.66). CONCLUSIONS: Esophageal cooling has been shown to be effective in reducing ablation-related thermal injury during RF ablation. This protection does not compromise standard procedural endpoints or clinical success at 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Recidiva
5.
Pacing Clin Electrophysiol ; 45(11): 1295-1298, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35687737

RESUMO

A 39-years old ventricular lead of a right-sided single-chamber pacemaker required extraction for infection. Angulation at the right subclavian-superior vena cava junction coupled with calcified fibrotic encapsulating tissue prevented advancement of a rotational dissecting sheath. To straighten the lead, it was pulled from the subclavian and out of the right internal jugular vein, whilst the Needle's-Eye Snare via the femoral access provided counter-traction. A 13-french rotational dissecting sheath was successfully advanced over the lead via the jugular access to complete the lead extraction without any complication.


Assuntos
Marca-Passo Artificial , Veia Cava Superior , Humanos , Adulto , Remoção de Dispositivo , Veias Jugulares/cirurgia , Artéria Femoral
6.
J Cardiovasc Electrophysiol ; 32(4): 1131-1139, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33565195

RESUMO

BACKGROUND: Cardiac resynchronization therapy-defibrillator (CRT-D) implantation via the cephalic vein is feasible and safe. Recent evidence has suggested a higher implantable cardioverter-defibrillator (ICD) lead failure in multi-lead defibrillator therapy via the cephalic route. We evaluated the relationship between CRT-D implantation via the cephalic and ICD lead failure. METHODS: Data was collected from three CRT-D implanting centers between October 2008 and September 2017. In total 633 patients were included. Patient and lead characteristics with ICD lead failure were recorded. Comparison of "cephalic" (ICD lead via cephalic) versus "non-cephalic" (ICD lead via non-cephalic route) cohorts was performed. Kaplan-Meier survival and a Cox-regression analysis were applied to assess variables associated with lead failure. RESULTS: The cephalic and non-cephalic cohorts were equally male (81.9% vs. 78%; p = .26), similar in age (69.7 ± 11.5 vs. 68.7 ± 11.9; p = .33) and body mass index (BMI) (27.7 ± 5.1 vs. 27.1 ± 5.7; p = .33). Most ICD leads were implanted via the cephalic vein (73.5%) and patients had a mean of 2.9 ± 0.28 leads implanted via this route. The rate of ICD lead failure was low and statistically similar between both groups (0.36%/year vs. 0.13%/year; p = .12). Female gender was more common in the lead failure cohort than non-failure (55.6% vs. 17.9%, respectively; p = .004) as was hypertension (88.9% vs. 54.2%, respectively, p = .038). On multivariate Cox-regression, female sex (p = .008; HR, 7.12 [1.7-30.2]), and BMI (p = .047; HR, 1.12 [1.001-1.24]) were significantly associated with ICD lead failure. CONCLUSION: CRT-D implantation via the cephalic route is not significantly associated with premature ICD lead failure. Female gender and BMI are predictors of lead failure.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Hipertensão , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Resultado do Tratamento
7.
Europace ; 23(3): 370-379, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33188692

RESUMO

AIMS: Restoring sinus rhythm (SR) by ablation alone is an endpoint used in radiofrequency (RF) ablation for long-standing persistent atrial fibrillation (AF) but not with cryotherapy. The simultaneous use of two cryotherapy catheters can improve ablation efficiency; we compared this with RF ablation in chronic persistent AF aiming for termination to SR by ablation alone. METHODS AND RESULTS: Consecutive patients undergoing their first ablation for persistent AF of >6 months duration were screened. A total of 100 participants were randomized 1:1 to multi-catheter cryotherapy or RF. For cryotherapy, a 28-mm Arctic Front Advance was used in tandem with focal cryoablation catheters. Open-irrigated, non-force sensing catheters were used in the RF group with a 3D mapping system. Pulmonary vein (PV) isolation and non-PV triggers were targeted. Participants were followed up at 6 and 12 months, then yearly. Acute PVI was achieved in all cases. More patients in the multi-catheter cryotherapy group were restored to SR by ablation alone, with a shorter procedure duration. Sinus rhythm continued to the last available follow-up in 16/49 patients (33%) in the multi-catheter at 3.0 ± 1.6 years post-ablation and in 12/50 patients (24%) in the RF group at 4.0 ± 1.2 years post-ablation. The yearly rate of arrhythmia recurrence was similar. CONCLUSION: Multi-catheter cryotherapy can restore SR by ablation alone in more cases and more quickly than RF ablation. Long-term success is difficult to achieve by either methods and is similar with both.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Crioterapia , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
8.
Europace ; 23(2): 205-215, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33205201

RESUMO

AIMS: Thermal injury to the oesophagus is an important cause of life-threatening complication after ablation for atrial fibrillation (AF). Thermal protection of the oesophageal lumen by infusing cold liquid reduces thermal injury to a limited extent. We tested the ability of a more powerful method of oesophageal temperature control to reduce the incidence of thermal injury. METHODS AND RESULTS: A single-centre, prospective, double-blinded randomized trial was used to investigate the ability of the ensoETM device to protect the oesophagus from thermal injury. This device was compared in a 1:1 randomization with a control group of standard practice utilizing a single-point temperature probe. In the protected group, the device maintained the luminal temperature at 4°C during radiofrequency (RF) ablation for AF under general anaesthesia. Endoscopic examination was performed at 7 days post-ablation and oesophageal injury was scored. The patient and the endoscopist were blinded to the randomization. We recruited 188 patients, of whom 120 underwent endoscopy. Thermal injury to the mucosa was significantly more common in the control group than in those receiving oesophageal protection (12/60 vs. 2/60; P = 0.008), with a trend toward reduction in gastroparesis (6/60 vs. 2/60, P = 0.27). There was no difference between groups in the duration of RF or in the force applied (P value range= 0.2-0.9). Procedure duration and fluoroscopy duration were similar (P = 0.97, P = 0.91, respectively). CONCLUSION: Thermal protection of the oesophagus significantly reduces ablation-related thermal injury compared with standard care. This method of oesophageal protection is safe and does not compromise the efficacy or efficiency of the ablation procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Esôfago/cirurgia , Humanos , Estudos Prospectivos , Temperatura , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 44(8): 1340-1346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34240439

RESUMO

BACKGROUND: The Sars-Cov-2 infection is a multisystem illness that can affect the cardiovascular system. Tachyarrhythmias have been reported but the prevalence of bradyarrhythmia is unclear. Cases have been described of transient high-degree atrioventricular (AV) block in COVID-19 that were managed conservatively. METHOD: A database of all patients requiring temporary or permanent pacing in two linked cardiac centers was used to compare the number of procedures required during the first year of the pandemic compared to the corresponding period a year earlier. The database was cross-referenced with a database of all patients testing positive for Sars-Cov-2 infection in both institutions to identify patients who required temporary or permanent pacing during COVID-19. RESULTS: The number of novel pacemaker implants was lower during the COVID-19 pandemic than the same period the previous year (540 vs. 629, respectively), with a similar proportion of high-degree AV block (38.3% vs. 33.2%, respectively, p = .069). Four patients with the Sars-Cov-2 infection had a pacemaker implanted for high-degree AV block, two for sinus node dysfunction. Of this cohort of six patients, two succumbed to the COVID-19 illness and one from non-COVID sepsis. Device interrogation demonstrated a sustained pacing requirement in all cases. CONCLUSION: High-degree AV block remained unaltered in prevalence during the COVID-19 pandemic. There was no evidence of transient high-degree AV block in patients with the Sars-Cov-2 infection. Our experience suggests that all clinically significant bradyarrhythmia should be treated by pacing according to usual protocols regardless of the COVID status.


Assuntos
Bradicardia/epidemiologia , Bradicardia/terapia , COVID-19/complicações , Estimulação Cardíaca Artificial , Idoso , Idoso de 80 Anos ou mais , Bradicardia/etiologia , Humanos , Masculino , Prevalência
10.
Pacing Clin Electrophysiol ; 44(4): 614-624, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33624296

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED)-related perforation is uncommon but potentially lethal. Management typically includes the use of computed tomography (CT) scanning and often involves cardiac surgery. METHODS: Patients presenting to a single referral centre with CIED-related cardiac perforation between 2013 and 2019 were identified. Demographics, diagnostic modalities, the method of lead revision, and 30-day complications were examined. RESULTS: A total of 46 cases were identified; median time from implantation to diagnosis was 14 days (interquartile range = 4-50). Most were females (29/46, 63%), 9/46 (20%) had cancer, 18 patients (39%) used oral anticoagulants, and no patients had prior cardiac surgery. Active fixation was involved in 98% of cases; 9% involved an implantable cardioverter defibrillator lead. Thirty-seven leads perforated the right ventricle (apex: 24) and 9 punctured the right atrium (lateral wall: 5). Abnormal electrical parameters were noted in 95% of interrogated cases. Perforation was visualized in 41% and 6% of cases with chest X-ray (CXR) and transthoracic echocardiography, respectively. CXR revealed a perforation, gross lead displacement, or left-sided pleural effusion in 74% of cases. Pericardial effusion occurred in 26 patients (57%) of whom 11 (24%) developed tamponade, successfully drained percutaneously. Pre-extraction CT scan was performed in 19 patients but was essential in four cases. Transvenous lead revision (TLR) was successfully performed in all cases with original leads repositioned in six patients, without recourse to surgery. Thirty-day mortality and complications were low (0% and 26%, respectively). CONCLUSION: CT scanning provides incremental diagnostic value in a minority of CIED-related perforations. TLR is a safe and effective strategy.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/cirurgia , Tomografia Computadorizada por Raios X , Idoso , Remoção de Dispositivo , Ecocardiografia , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Estudos Prospectivos , Reoperação , Fatores de Risco
11.
Pacing Clin Electrophysiol ; 43(12): 1515-1520, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32860243

RESUMO

BACKGROUND: Small series has shown that cardiac resynchronisation therapy (CRT) can be achieved in a majority of patients using exclusively cephalic venous access. We sought to determine whether this method is suitable for widespread use. METHODS: A group of 19 operators including 11 trainees in three pacing centres attempted to use cephalic access alone for all CRT device implants over a period of 8 years. The access route for each lead, the procedure outcome, duration, and complications were collected prospectively. Data were also collected for 105 consecutive CRT device implants performed by experienced operators not using the exclusively cephalic method. RESULTS: A new implantation of a CRT device using exclusively cephalic venous access was attempted in 1091 patients (73.6% male, aged 73 ± 12 years). Implantation was achieved using cephalic venous access alone in 801 cases (73.4%) and using a combination of cephalic and other access in a further 180 (16.5%). Cephalic access was used for 2468 of 3132 leads implanted (78.8%). Compared to a non-cephalic reference group, complications occurred less frequently (69/1091 vs 12/105; P = .0468), and there were no pneumothoraces with cephalic implants. Procedure and fluoroscopy duration were shorter (procedure duration 118 ± 45 vs 144 ± 39 minutes, P < .0001; fluoroscopy duration 15.7 ± 12.9 vs 22.8 ± 12.2 minutes, P < .0001). CONCLUSIONS: CRT devices can be implanted using cephalic access alone in a substantial majority of cases. This approach is safe and efficient.


Assuntos
Veia Axilar , Dispositivos de Terapia de Ressincronização Cardíaca , Cateterismo Periférico/métodos , Competência Clínica , Idoso , Terapia de Ressincronização Cardíaca/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos
13.
Europace ; 19(8): 1317-1321, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702870

RESUMO

AIM: The Biosense Webster ThermoCool® SmartTouch® Surround Flow (STSF) catheter is a recently developed ablation catheter incorporating Surround Flow (SF) technology to ensure efficient cooling and force sensing to quantify tissue contact. In our unit, it superseded the ThermoCool® SF catheter from the time of its introduction in May 2015. METHODS AND RESULTS: Procedure-related data were collected prospectively for the first 100 ablation procedures performed in our department using the STSF catheter. From a database of 654 procedures performed in our unit using the SF catheter, we selected one to match each STSF procedure, matching for procedure type, operator experience, patient age, and gender. The groups were well matched for patient age, gender, and procedure type. Procedure duration was similar in both groups (mean 225.5 vs. 221.4 min, IQR 106.5 vs. 91.5, P = 0.55), but fluoroscopy duration was shorter in the STSF group (mean 25.8 vs. 30.0, IQR 19.6 vs. 18.5, P = 0.03). No complication occurred in the STSF group. Complications occurred in two cases in the SF group (one pericardial effusion requiring drainage and one need for permanent pacing). Complete procedural success was achieved in 98 cases in the STSF group and 94 cases in the SF group (P = 0.15). The composite endpoint of procedure failure or acute complication was less common in the STSF group (2 vs. 8, P = 0.05). CONCLUSION: The STSF catheter is safe and effective in treating a range of arrhythmias. Compared with the SF catheter, it shows a trend towards improved safety-efficacy balance.


Assuntos
Arritmias Cardíacas/cirurgia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Irrigação Terapêutica/instrumentação , Transdutores de Pressão , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Bases de Dados Factuais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
14.
Circ Res ; 111(2): e19-31, 2012 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-22647876

RESUMO

RATIONALE: Nkx2.5 is one of the most widely studied cardiac-specific transcription factors, conserved from flies to man, with multiple essential roles in both the developing and adult heart. Specific dominant mutations in NKX2.5 have been identified in adult congenital heart disease patients presenting with conduction system anomalies and recent genome-wide association studies implicate the NKX2.5 locus, as causative for lethal arrhythmias ("sudden cardiac death") that occur at a frequency in the population of 1 in 1000 per annum worldwide. Haploinsufficiency for Nkx2.5 in the mouse phenocopies human conduction disease pathology yet the phenotypes, described in both mouse and man, are highly pleiotropic, implicit of unknown modifiers and/or factors acting in epistasis with Nkx2.5/NKX2.5. OBJECTIVE: To identify bone fide upstream genetic modifier(s) of Nkx2.5/NKX2.5 function and to determine epistatic effects relevant to the manifestation of NKX2.5-dependent adult congenital heart disease. METHODS AND RESULTS: A study of cardiac function in prospero-related homeobox protein 1 (Prox1) heterozygous mice, using pressure-volume loop and micromannometry, revealed rescue of hemodynamic parameters in Nkx2.5(Cre/+); Prox1(loxP/+) animals versus Nkx2.5(Cre/+) controls. Anatomic studies, on a Cx40(EGFP) background, revealed Cre-mediated knock-down of Prox1 restored the anatomy of the atrioventricular node and His-Purkinje network both of which were severely hypoplastic in Nkx2.5(Cre/+) littermates. Steady state surface electrocardiography recordings and high-speed multiphoton imaging, to assess Ca(2+) handling, revealed atrioventricular conduction and excitation-contraction were also normalized by Prox1 haploinsufficiency, as was expression of conduction genes thought to act downstream of Nkx2.5. Chromatin immunoprecipitation on adult hearts, in combination with both gain and loss-of-function reporter assays in vitro, revealed that Prox1 recruits the corepressor HDAC3 to directly repress Nkx2.5 via a proximal upstream enhancer as a mechanism for regulating Nkx2.5 function in adult cardiac conduction. CONCLUSIONS: Here we identify Prox1 as a direct upstream modifier of Nkx2.5 in the maintenance of the adult conduction system and rescue of Nkx2.5 conduction disease phenotypes. This study is the first example of rescue of Nkx2.5 function and establishes a model for ensuring electrophysiological function within the adult heart alongside insight into a novel Prox1-HDAC3-Nkx2.5 signaling pathway for therapeutic targeting in conduction disease.


Assuntos
Epistasia Genética/genética , Sistema de Condução Cardíaco/fisiopatologia , Cardiopatias/genética , Cardiopatias/metabolismo , Histona Desacetilases/genética , Proteínas de Homeodomínio/genética , Fenótipo , Fatores de Transcrição/genética , Proteínas Supressoras de Tumor/genética , Animais , Cardiopatias/fisiopatologia , Histona Desacetilases/fisiologia , Proteína Homeobox Nkx-2.5 , Proteínas de Homeodomínio/fisiologia , Camundongos , Camundongos Transgênicos , Células NIH 3T3 , Fatores de Transcrição/fisiologia , Proteínas Supressoras de Tumor/fisiologia
15.
Indian Pacing Electrophysiol J ; 14(1): 26-31, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24493913

RESUMO

We describe a patient presenting with incessant ectopic atrial tachycardia during a high risk twin pregnancy. Tachycardia was resistant to escalating doses of beta-blockade with digoxin. Because of increasing left ventricular dysfunction early in the third trimester, catheter ablation was performed successfully at 30 weeks gestation. Electro-anatomic mapping permitted the entire procedure to be conducted without the use of ionizing radiation. The pregnancy proceeded to successful delivery near term and after three years the patient remains recurrence free with normal left ventricular function, off all medication.

16.
Kardiol Pol ; 80(7-8): 750-759, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35724337

RESUMO

Recent decades have seen a series of advances in percutaneous transvenous procedures for cardiac arrhythmias, including the implantation of leadless pacemakers. Many of these procedures require the insertion of large caliber sheaths in large veins, usually the femoral vein. Securing hemostasis efficiently and reliably at the access site is a key step to improving a procedure's safety profile. Traditionally, hemostasis was achieved by manual compression of venous access sites, but the trend toward larger sheaths and the increased use of uninterrupted anticoagulation has pushed the limits of this method. Achieving hemostasis by compression alone in these circumstances requires more attention and longer duration, leading to greater patient discomfort and prolonged immobility. In turn, manual compression may be more time-consuming for medical professionals and increase the number of occupied hospital beds. New approaches have been developed to facilitate early ambulation, decrease patient discomfort, and address the risk of access site complications. These approaches include vascular closure devices and subcutaneous suture techniques including figureof- eight and purse-string sutures. This article reviews the new approaches applied to achieve venous access site hemostasis in patients undergoing transvenous procedures for cardiac arrhythmias.


Assuntos
Técnicas de Sutura , Suturas , Arritmias Cardíacas/cirurgia , Artéria Femoral/cirurgia , Hemostasia , Humanos , Resultado do Tratamento
17.
J Clin Med ; 11(7)2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35407640

RESUMO

COVID-19 causes severe illness that results in morbidity and mortality. Electrocardiographic features, including QT prolongation, have been associated with poor acute outcomes; data on the medium-term outcomes remain scarce. This study evaluated the 1-year outcomes of patients who survived the acute COVID-19 infection. Methods and Materials: Data of the 159 patients who survived the COVID-19 illness during the first wave (1 March 2020−18 May 2020) were collected. Patient demographics, laboratory findings and electrocardiography data were evaluated. Patients who subsequently died within 1-year of the index illness were compared to those who remained well. Results: Of the 159 patients who had survived the index illness, 28 (17.6%) subsequently perished within 1-year. In comparison to the patients that were alive after 1-year, the deceased were older (68 vs. 83 years, p < 0.01) and equally male (60.4% vs. 53.6%, p = 0.68), with a similar proportion of hypertension (59.5% vs. 57.1%, p = 0.68), diabetes (25.2% vs. 39.2%, p = 0.096) and ischaemic heart disease (11.5% vs. 7.1%, p = 0.54). The QTc interval for the alive and deceased patients shortened by a similar degree from the illness to post-COVID (−26 ± 33.5 vs. −20.6 ± 30.04 milliseconds, p = 0.5); the post-COVID R-R interval was longer in the alive patients compared to the deceased (818.9 ± 169.3 vs. 761.1 ± 61.2 ms, p = 0.02). A multivariate Cox regression analysis revealed that age (HR1.098 [1.045−1.153], p < 0.01), diabetes (HR3.972 [1.47−10.8], p < 0.01) and the post-COVID R-R interval (HR0.993 [0.989−0.996], p < 0.01) were associated with 1-year mortality. Conclusions: The COVID-19-associated mortality risk extends to the post-COVID period. The QTc does recover following the acute illness and is not associated with outcomes; the R-R interval is a predictor of 1-year mortality.

18.
J Interv Card Electrophysiol ; 60(3): 543-553, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32440943

RESUMO

PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Catéteres , Desenho de Equipamento , Humanos , Resultado do Tratamento
19.
J Mol Cell Cardiol ; 47(1): 133-41, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19376125

RESUMO

Elevated levels of the cardiac transcription factor Hand1 have been reported in several adult cardiac diseases but it is unclear whether this change is itself maladaptive with respect to heart function. To test this possibility, we have developed a novel, inducible transgenic system, and used it to overexpress Hand1 in adult mouse hearts. Overexpression of Hand1 in the adult mouse heart leads to mild cardiac hypertrophy and a reduction in life expectancy. Treated mice show no significant fibrosis, myocyte disarray or congestive heart failure, but have a greatly reduced threshold for induced ventricular tachycardia, indicating a predisposition to cardiac arrhythmia. Within 48 h, they show a significant loss of connexin43 protein from cardiac intercalated discs, with increased intercalated disc beta-catenin expression at protein and RNA levels. These changes are sustained during prolonged Hand1 overexpression. We propose that cardiac overexpression of Hand1 offers a useful mouse model of arrhythmogenesis and elevated HAND1 may provide one of the molecular links between the failing heart and arrhythmia.


Assuntos
Arritmias Cardíacas/genética , Arritmias Cardíacas/metabolismo , Fatores de Transcrição Hélice-Alça-Hélice Básicos/fisiologia , Animais , Fatores de Transcrição Hélice-Alça-Hélice Básicos/genética , Cardiomegalia/genética , Cardiomegalia/metabolismo , Eletrofisiologia , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/metabolismo , Humanos , Imuno-Histoquímica , Técnicas In Vitro , Masculino , Camundongos , Camundongos Transgênicos , Reação em Cadeia da Polimerase Via Transcriptase Reversa