Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Dis Child Fetal Neonatal Ed ; 103(1): F49-F55, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28663283

RESUMO

OBJECTIVE: To verify whether the use of the T-piece resuscitator compared with the self-inflating bag in preterm infants ventilated at birth modifies survival to hospital discharge without major morbidities. DESIGN: Pragmatic prospective cohort study. SETTING: 20 Brazilian university hospitals of Brazilian Network on Neonatal Research. Patients were 1962 inborn infants in 2014-2015 ventilated at birth with 23-33' weeks gestation and birth weight 400-1499 g without malformations. Patients transferred until the 27th day after birth were excluded. INTERVENTIONS: Positive pressure ventilation at birth with T-piece resuscitator or self-inflating bag without positive end expiratory pressure valve. Intervention with ventilation followed the Brazilian Society of Pediatrics guidelines. The choice of the equipment was at the neonatologist's discretion in each delivery. The main outcome measures were survival to hospital discharge without bronchopulmonary dysplasia, severe peri-intraventricular haemorrhage and periventricular leucomalacia. Logistic regression adjusted for confounding variables was applied for main outcome. RESULTS: 1456 (74%) were only ventilated with T-piece resuscitator and 506 (26%) with the self-inflating bag. The characteristics of those ventilated with T-Piece resuscitator versus self-inflating bag were birth weight 969 ± 277 vs 941 ± 279 g, gestational age 28.2±2.5 vs 27.8±2.7 weeks and survival to hospital discharge without major morbidities 47% vs 35%. Logistic regression adjusted for maternal characteristics, obstetric and neonatal morbidities showed that the T-piece resuscitator increased the chance of survival to hospital discharge without major morbidities (OR=1.38; 95% CI 1.06 to 1.80; Hosmer-Lemeshow goodness of fit: 0.695). CONCLUSION: This study is the first that highlights the effectiveness of T-piece resuscitator ventilation in improving relevant outcomes in preterm neonates.


Assuntos
Doenças do Prematuro , Recém-Nascido Prematuro/fisiologia , Respiração com Pressão Positiva , Respiração Artificial , Ventiladores Mecânicos , Brasil/epidemiologia , Estudos de Coortes , Desenho de Equipamento , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Doenças do Prematuro/epidemiologia , Doenças do Prematuro/etiologia , Insuflação/métodos , Masculino , Alta do Paciente/estatística & dados numéricos , Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/métodos , Gravidez , Resultado da Gravidez/epidemiologia , Nascimento Prematuro/epidemiologia , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Análise de Sobrevida , Ventiladores Mecânicos/efeitos adversos , Ventiladores Mecânicos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA