Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 97(6): E897-E899, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33491842

RESUMO

Severe symptomatic tricuspid regurgitation (TR) remains an undertreated disease. Multiple trans-catheter treatment options are currently under investigation. Transcatheter caval valve implantation (CAVI) has been utilized as a treatment option and aims at decreasing or eliminating the caval backflow that occurs in severe TR patients. Understanding challenges with this therapy is paramount. Hereby we present a CAVI case with resultant non-coaptation of valve leaflets in a patient with a prominent Eustachian ridge.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco/efeitos adversos , Catéteres , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
2.
Europace ; 19(3): 452-457, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27247009

RESUMO

AIMS: The first aim of this study was to determine the size of the Koch's triangle. The second one was to investigate relation between its dimensions and other individual-specific and heart-specific parameters as well as to create universal formula to estimate triangle dimensions based on these parameters. METHODS AND RESULTS: This study is a prospective one, presenting 120 randomly selected autopsied hearts dissected from adult humans (Caucasian) of both sexes (31.7% females), with mean age of 49.3 ± 17.4 years. The length of triangle sides and angles were measured and the triangle area was calculated as well. Sixteen additional heart parameters were measured in order to analyse potential relationship between the dimensions of Koch's triangle and other dimensions of the heart, using linear regression analysis. The mean (±SD) length of the anterior edge was approximated to 18.0 ± 3.8 mm, the posterior edge to 20.3 ± 4.3 mm, and the basal edge to 18.5 ± 4.0 mm. The average values of the apex angle, the Eustachian angle, and the septal leaflet angle were 58.0 ± 14.4°, 53.8 ± 10.6°, and 67.6 ± 14.4°, respectively. The mean value of the Koch's triangle area was 151.5 ± 55.8 mm2. The 95th percentile of triangle's height (the distance from the apex to the coronary sinus) was 21.8 mm. CONCLUSION: Mean values and proportions of triangle's sides and angles were presented. Koch's triangle showed considerable individual variations in size. The dimensions of the triangle were strongly independent from individual-specific and heart-specific morphometric parameters; however, the maximum triangle's height can be estimated as 22 mm.


Assuntos
Pontos de Referência Anatômicos , Septo Interatrial/anatomia & histologia , Seio Coronário/anatomia & histologia , Valva Tricúspide/anatomia & histologia , Adulto , Autopsia , Dissecação , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , População Branca