Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39326806

RESUMO

INTRODUCTION: The impact of femoral anteversion changes on femoral rotation and anterior offset following total hip arthroplasty (THA) has not been well studied. This study therefore investigated the relationship between femoral anteversion, anterior offset, and femoral rotation before and after THA. METHODS: There were 995 patients who had staged primary bilateral THAs who received a preoperative supine computerized axial tomography (CT) scan, following a standardized protocol, for surgical planning prior to each THA. The following measurements were performed for the first operative hip preoperatively and postoperatively on the first and second CT scans, respectively: femoral anatomic anteversion, defined as the angle between the native femoral neck or stem neck axis and the posterior condylar axis; femoral rotation, defined as the angle of the posterior condylar axis relative to the coronal plane of the CT; and femoral anterior offset, defined as the shortest distance between the femoral head center and a femoral plane containing the epicondyles and the piriformis fossa. The mean time between imagings was 11 months (range, 2 to 44). Associations are described using linear regression (ß = slope) and Pearson correlation (r) coefficients. A t distribution was used for testing correlational significance. RESULTS: Femoral anteversion correlated with femoral anterior offset preoperatively (ß = 0.565, r = 0.914, P < 0.0001) and postoperatively (ß = 0.671, r = 0.958, P < 0.0001), and with femoral rotation preoperatively (ß = 0.623, r = 0.575, P < 0.0001) and postoperatively (ß = 0.459, r = 0.517, P < 0.0001). Increasing anteversion from preoperatively to postoperatively increased anterior offset (ß = 0.621, r = 0.908, P < 0.0001) and femoral internal rotation (ß = 0.241, r = 0.273, P < 0.0001). Patients who had > 20° increase in anteversion (mean increase 26°, range 20 to 40.5°, n = 71) had a mean increase in femoral internal rotation of 9.6 ± 9.8°. CONCLUSIONS: Increasing femoral anteversion increases anterior offset and internal rotation of the femur, with approximately a 1° increase in internal rotation for every 4° increase in anteversion on average. Surgeons should appreciate the implications of changing anteversion during THA planning.

2.
J Arthroplasty ; 39(9S2): S332-S339.e2, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38897260

RESUMO

BACKGROUND: Accurate hip reconstruction is associated with improved biomechanical behavior following total hip arthroplasty (THA). However, whether this is associated with improved patient-reported outcomes (PROs) is unknown. HYPOTHESIS/PURPOSE: This study aimed to: 1) describe the ability to reconstruct coronal geometry during THA without advanced technology; 2) assess whether restoration of global offset (GO) and leg length (LL) is associated with improved PROs; and 3) investigate whether increased femoral offset (FO) to compensate for reduced acetabular offset (AO) influences PROs. METHOD: This was a prospective, multicenter, consecutive cohort study of 500 patients treated with primary THA without robotics or navigation. The Oxford Hip score (OHS) was obtained preoperatively and at 1-year follow-up. Supine anteroposterior pelvic radiographs were analyzed to determine AO, FO, GO, and LL relative to the native contralateral side. Contour plots for ΔOHS based on ΔLL and ΔGO were created, and ΔOHS was calculated within and outside various ranges (±2.5, ±5, or ±10 mm). RESULTS: In the operated hip, mean FO increased by 3 ± 6 mm (range, -16 to 27), while AO decreased by 2 ± 4 mm (range, -17 to 10). The contour graph for ±2.5 mm zones showed the best outcomes (ΔOHS >25) with GO and LL centered on 0 ± 2.5 mm (P < .01). However, only 10% achieved such reconstruction. When GO and LL differences were within ±10 mm, ΔOHS was superior when both AO and FO were within ±5 mm (mean: 24 ± 10; range, -5 to 40) compared with when FO was above 5 mm to compensate for a reduction in AO (mean: 22 ± 11; range, -10 to 46; P = .040). CONCLUSIONS: The PROs were associated with biomechanical reconstruction, and the best clinical improvement can be expected when GO and LL differences are both within 2.5 mm. Maintenance of AO is important, as compensation by increasing FO is associated with inferior OHS.


Assuntos
Artroplastia de Quadril , Articulação do Quadril , Medidas de Resultados Relatados pelo Paciente , Humanos , Artroplastia de Quadril/métodos , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fenômenos Biomecânicos , Desigualdade de Membros Inferiores/etiologia , Prótese de Quadril , Radiografia
3.
J Arthroplasty ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38909856

RESUMO

BACKGROUND: Trochanteric bursitis (TB) is a prevalent complication following total hip arthroplasty (THA), with increased offset hypothesized as a potential risk factor. This study investigated potential TB predictors in THA patients, including radiographic measurements of offset and leg length, comorbidities, and patient characteristics. METHODS: In this retrospective cohort study, all THA patients from a single academic tertiary care center between 2005 and 2021 were reviewed. Exclusion criteria included less than one-year follow-up, osteonecrosis, or fracture. Manual radiographic measurements of offset (acetabular, femoral, and total) and leg length from preoperative and postoperative antero-posterior pelvis X-rays were taken, with scaling using femoral cortical diameter. Univariable and multivariable Cox proportional hazard models were employed to estimate TB risk. RESULTS: Of 1,094 patients, 103 (9.4%) developed TB, with a median (Q1, Q3) time to presentation of 41.8 weeks (25.5, 66.9). In univariable models, only sex was associated with increased TB risk, with women exhibiting a 1.79 times increased risk (hazard ratio: 1.79 (1.16, 2.76), P = .009). Changes in acetabular offset, femoral offset, total offset, and leg length between preoperative and postoperative radiographs were not associated with an increased risk of developing TB in the univariate or multivariate models. Furthermore, various offset thresholds were evaluated, with no amount of increased offset showing increased TB risk. CONCLUSIONS: This study found no relationship between femoral, acetabular, or total offset and TB following THA. These findings suggest that surgeons may consider adding offset for increased prosthetic stability in high-risk cases. However, given that this is a retrospective study, the authors are not advocating for the routine use of increased offset. The study identified women as a risk factor with a 1.79 times higher TB risk, highlighting the importance of counseling women patients on this heightened risk.

4.
Int Orthop ; 48(5): 1217-1224, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38388804

RESUMO

PURPOSE: Lateralized stems in primary cementless total hip arthroplasty (THA) showed to be associated with aseptic femoral loosening. However, femoral head length also affects femoral offset but was not considered so far. This study analyzed the impact of high femoral offset (hFO) combinations, formed by lateralized stems or large femoral head lengths, on aseptic femoral component loosening. METHODS: Retrospective cohort study was performed including all patients that underwent primary cementless THA at our institution between July 2004 and December 2016. Patients were screened for aseptic femoral component loosening and grouped in aseptic loosening (AL) and non-aseptic loosening (nAL) group. Medical records were screened; implant details were noted and classified in hFO and standard femoral offset (sFO) combinations. Supposed risk factors for aseptic loosening were analyzed. RESULTS: Two thousand four hundred fifty-nine THA could be included, containing 14 THA (0.6%) with aseptic femoral component loosening. The AL group contained 11 hFO combinations (78.6%), whereas in the nAL group, 1315 hFO combinations (53.8%) were used. Subgroup analysis showed significant difference between two groups for hFO combinations (p = 0.014), age (p = 0.002), NSAR (p = 0.001), and bilateral THA on same day (p = 0.001). The multiple logistic regression analysis showed that hFO combination was the only variable for increased probability of aseptic loosening (OR, 3.7; p = 0.04). CONCLUSION: High femoral offset combinations, formed by lateralized stems or large femoral head lengths in our collective of standard straight stems implanted by an anterior approach, show a 3.7-fold increased probability for aseptic femoral component loosening. Adjustment of the postoperative protocol may be considered in these cases to ensure proper stem ingrowth.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Seguimentos , Falha de Prótese , Reoperação/efeitos adversos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
5.
Arch Orthop Trauma Surg ; 144(4): 1781-1792, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38147077

RESUMO

BACKGROUND: Positioning implant components and restoring patient anatomy during total hip arthroplasty (THA) are essential for joint stability, polyethylene liner wear, and range of motion. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during the posterior or posterolateral approach have reported conflicting results. This meta-analysis evaluated if intraoperative fluoroscopy improves component positioning and femoral component position compared to no fluoroscopy during posterior or posterolateral approach total hip arthroplasty. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses standards were followed when conducting the systematic review. We searched Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving Intraoperative fluoroscopy versus no fluoroscopy during posterior or posterolateral approach total hip arthroplasty. Finally, we identified 1133 patients (1145 hips) assessed in seven studies. RESULTS: There were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.43), ACIA within safe zone rate (P = 0.58), acetabular cup anteversion angle (ACAA, P = 0.46); ACAA within safe zone rate (P = 0.72), Combined safe zone rate (P = 0.28), dislocation rate (P = 0.64) and infection rate (P = 0.94) between two groups. Compared with the no fluoroscopy group, the intraoperative fluoroscopy group had more operation time (P < 0.00001), less femoral component offset difference (FCOD, P = 0.03), and less LLD (P < 0.00001). CONCLUSION: Even though intraoperative fluoroscopy was not related to an improvement in cup location or dislocation incidence. Our findings demonstrate that the restoration of leg lengths and femoral offset can be significantly improved by using intraoperative fluoroscopy to supplement good surgical skills in THA. The advantages of intraoperative fluoroscopy might become more apparent for surgeons with less experience. To ascertain whether intraoperative fluoroscopy for posterior or posterolateral approach total hip arthroplasty will have clinical benefits and improve the survival of prostheses, more well-powered and well-designed long-term follow-up studies were necessary.


Assuntos
Acetábulo , Artroplastia de Quadril , Humanos , Fluoroscopia/métodos , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Prótese de Quadril
6.
BMC Musculoskelet Disord ; 24(1): 567, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37434207

RESUMO

BACKGROUND: Femoral offset (FO) restoration plays an important role in improving the prognosis and quality of life of patients undergoing hip replacement. However, it is not given enough attention in revisions among patients with periprosthetic femoral fractures (PPFFs); instead, more attention is given to reduction, fixation of fractures and stabilizing prostheses. The primary objective of this study was to evaluate the effect of FO restoration on the function of the hip joint in revisions of patients with PPFF of Vancouver B2. Moreover, we studied whether there is a difference in FO restoration between modular and nonmodular stems. METHODS: A retrospective review of 20 patients with PPFF of Vancouver B2 revised with a tapered fluted modular titanium stem and 22 patients with PPFF of Vancouver B2 revised with a tapered fluted nonmodular titanium stem from 2016 to 2021 was conducted. Based on the difference between the FO of the affected side and that of the healthy side, 26 patients were allocated into Group A (difference ≤ 4 mm), and 16 patients were allocated into Group B (difference > 4 mm). The postoperative Harris Hip Score (HHS), range of motion of the hip joint, length of both lower limbs and dislocation were compared between Group A and Group B. The proportions of patients with FO restoration (difference ≤ 4 mm) and stem subsidence were compared between the modular and nonmodular groups. RESULTS: The mean follow-up time was 34.3 ± 17.3 months, and all cases achieved fracture healing at the last visit. Patients in Group A had a higher HHS, larger range of abduction, fewer dislocations and less limb length discrepancy (LLD). Patients in the modular group had a higher proportion of FO restoration and less subsidence. CONCLUSION: FO restoration improves postoperative hip joint function and reduces dislocation and LLD in revisions of patients with PPFF of Vancouver B2. Compared with nonmodular prostheses, modular prostheses tend to be easier for FO restoration under complex circumstances.


Assuntos
Fraturas do Fêmur , Luxações Articulares , Humanos , Estudos Retrospectivos , Qualidade de Vida , Titânio , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur
7.
Int Orthop ; 47(9): 2245-2251, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37188902

RESUMO

PURPOSE: Failure to restore the femoral offset of the native hip is a potential cause of dysfunctional hip arthroplasty. The aim of this study was to report our experience of using a modular head-neck adapter in revision THA, specifically analyzing its usefulness as a tool to correct a slightly diminished femoral offset. MATERIALS AND METHODS: This was a retrospective single-center study including all hip revisions performed at our institution from January 2017 to March 2022 where the BioBallTM head-neck metal adapter was used. The preoperative and one year follow-up modified Merle d'Aubigné hip score was used to evaluate functional outcomes. RESULTS: Of a total of 34 cases included for revision, the head-neck adapter system was used specifically in six patients (17.6%) to increase femoral offset, retaining both the acetabular and femoral components. In this subgroup of patients, mean offset decrease after primary THA was 6.6 mm (4.0-9.1), equivalent to a mean 16.3% femoral offset reduction. The median modified Merle d'Aubigné score went from 13.3 preoperatively to 16.2 at one year follow-up. CONCLUSION: The use of a head-neck adapter is a safe and reliable procedure that may allow the surgeon to easily correct a slightly diminished femoral offset in a dysfunctional THA without the need to revise well-fixed prosthetic components.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Fêmur/cirurgia , Acetábulo/cirurgia , Reoperação , Falha de Prótese
8.
Arch Orthop Trauma Surg ; 143(1): 519-527, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34997306

RESUMO

PURPOSE: Short stems are increasingly used in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Digital templating is essential in determining the correct offset option and stem size in THA. However, the preoperative template sizes might be intraoperatively overruled. PATIENTS AND METHODS: We evaluated the effect of intraoperative overruling of the preoperatively templated offset option of a short curved stem on hip offset, leg length, implant positioning, and femoral canal fill index. The overruling was performed in case of intraoperative instability, telescoping, or both. A series of 1052 consecutive THAs with a cementless short curved stem and press-fit cup was retrospectively screened. One hundred patients with unilateral THA and a contralateral native and morphologically healthy hip as a reference met the inclusion criteria. Measurements were carried out on preoperative and 3 months anterior-posterior postoperative radiographs. Patients were divided according to the overruling by offset option or stem size. RESULTS: Hip offset was increased in all groups, but only with significant increase if an offset option + 1 was used intraoperatively (p = 0.025). LLD was restored without significance in all groups (p = 0.323; p = 0.157). CONCLUSION: Intraoperative overruling of the preoperative digital template in cementless short stem total hip arthroplasty results in an increase of hip offset compared to a contralateral healthy hip. However, the increase is marginal and clearly under 5 mm compared to the contralateral healthy hip.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Radiografia , Osso e Ossos/cirurgia , Articulação do Quadril/cirurgia
9.
Arch Orthop Trauma Surg ; 143(6): 3541-3549, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36001169

RESUMO

INTRODUCTION: Differences in leg and hip morphology exist between sexes and developmental hip dysplasia is known to alter proximal femoral morphology. The purpose of this study was to determine whether existing differences in leg alignment due to sex or developmental hip dysplasia have an effect on changes in leg alignment after total hip arthroplasty. MATERIALS AND METHODS: 30 hip osteoarthritis patients underwent biplanar full-length radiography in the standing position preoperatively and 3 months after total hip arthroplasty. Differences in leg alignment between men and women and between patients with primary hip osteoarthritis and patients with developmental dysplasia before and after surgery were tested using a general linear model for repeated measures. RESULTS: Implantation of a hip prosthesis had no differential effect on ipsilateral leg alignment in patients with hip osteoarthritis due to dysplasia and in patients with primary hip osteoarthritis. However, patients with hip osteoarthritis due to dysplasia had a 2.1° higher valgus both before and after surgery. After total hip arthroplasty, women had a significantly greater increase in varus angle (1.6° vs. 0°) and femoral offset (10.5 vs. 4.6 mm) compared with men. Because the change in acetabular offset was smaller (2.2 vs. 6.2 mm), the global femoral offset was only increased in women. Femoral torsion was constant for men (15.0° and 16.5°), whereas femoral torsion was significantly reduced in women (19.9° and 13.2°). CONCLUSIONS: Hip arthroplasty has a greater effect on leg axis in women than in men. The axial leg alignment of women could change from a natural valgus to a varus alignment. Therefore, surgeons should consider the effects of total hip arthroplasty on leg alignment in patients with hip osteoarthritis. Whether these changes in leg alignment are also clinically relevant and lead to premature medial or lateral knee osteoarthritis should be investigated in future work. TRIAL REGISTRATION: This study was registered with DRKS (German Clinical Trials Register) under the number DRKS00015053. Registered 1st of August 2018.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Osteoartrite do Quadril , Osteoartrite do Joelho , Feminino , Humanos , Masculino , Fêmur/cirurgia , Luxação Congênita de Quadril/complicações , Luxação Congênita de Quadril/cirurgia , Articulação do Joelho/cirurgia , Perna (Membro) , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/etiologia , Osteoartrite do Quadril/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
10.
Arch Orthop Trauma Surg ; 142(10): 2935-2944, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34554313

RESUMO

PURPOSE: Short stems are increasingly used in in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Short stems can be inserted in a more varus position compared to conventional straight stems. This poses the risk of final varus misplacement of the femoral component, which is not intended in all femoral short stems. METHODS: We wanted to evaluate the effect of a high varus stem positioning in MIS THA on hip offset, leg length and femoral canal fill index. A series of 1052 consecutive THAs with a singular cementless femoral short stem and press-fit cup was retrospectively screened for inclusion. One hundred six patients with unilateral THA and a contralateral healthy hip met the inclusion criteria. Measurements were carried out on preoperative and 3 months anterior-posterior postoperative radiographs. Patients were divided into Group A (varus stem alignment ≤ 3°) and Group B (varus stem alignment > 3°). RESULTS: Hip offset (HO) increased significantly in Group B by 4 mm (p = 0.013). No influence on leg length difference was detected in both groups. Preoperative CCD angle was significantly lower in Group B (p < 0.001). Canal Fill Indices (CFI) were significantly lower in Group B (CFI I: p < 0.001; CFI II p = 0.003; CF III p = 0.002). CONCLUSION: High varus stem alignment > 3° leads to a statistically significant but minor increase in HO and poses the risk of stem undersizing. A preoperatively low genuine CCD angle pose a risk for varus stem positioning.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Perna (Membro) , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia , Estudos Retrospectivos
11.
Reumatologia ; 60(5): 340-346, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36381207

RESUMO

Introduction: Femoral neck fracture is one of the most common orthopaedic traumas affecting the elderly population. The standard treatment method is hip hemiarthroplasty and total hip arthroplasty. In hip hemiprostheses surgeons mainly have to reconstruct the femoral offset and limbs' length to obtain the correct gait biomechanics and a satisfactory surgical outcome.The aim of this study is to examine the radiological results of patients after hip hemiarthroplasty for femoral neck fracture and to evaluate the reconstruction of the femoral offset using standard neck angle stems. Material and methods: A consecutive series of 97 patients diagnosed with femoral neck fracture treated with a hip hemiprosthesis between 2017 and 2021 was identified and met the inclusion criteria. On preoperative images, the neck-shaft angle and the femoral offset on the healthy limb were measured. The femoral offset of the operated limb was measured on the postoperative X-rays. Results: There was a significant positive moderate correlation between neck-shaft angle and femoral offset change (r = 0.568, p < 0.0001). There was a statistically significant difference between femoral offset change and neck-shaft angle (24:52 vs. 14:7, p = 0.005). This means that in patients with coxa vara the change in femoral offset was more often < -5 mm. Less than half of operated patients had the femoral offset restored within a safe range (between -5 and 5 mm). Conclusions: Our study proved that it is sometimes hard to achieve femoral offset within a safe range while performing hip hemiarthroplasty in patients with coxa vara. The topic of using high offset stems in partial hip arthroplasty has not been thoroughly researched worldwide. However, taking into account the results of our study, during a hip hemiarthroplasty the usage of high offset stems for varus hips should be considered in order to improve the clinical outcome and improve patients' quality of life and functioning.

12.
BMC Musculoskelet Disord ; 22(1): 310, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33781252

RESUMO

BACKGROUND: Inaccurate projection on standard pelvic radiographs leads to the underestimation of femoral offset-a critical determinant of postoperative hip function-during total hip arthroplasty (THA) templating. We noted that the posteromedial facet of the greater trochanter and piriformis fossa form a double contour on radiographs, which may be valuable in determining the risk of underestimating femoral offset. We evaluate whether projection errors can be predicted based on the double contour width. METHODS: Plain anteroposterior (AP) pelvic radiographs and magnetic resonance images (MRIs) of 64 adult hips were evaluated retrospectively. Apparent femoral offset, apparent femoral head diameter and double contour widths were evaluated from the radiographs. X-ray projection errors were estimated by comparison to the true neck length measured on MRIs after calibration to the femoral heads. Multivariate analysis with backward elimination was used to detect associations between the double contour width and radiographic projection errors. Femoral offset underestimation below 10% was considered acceptable for templating. RESULTS: The narrowest width of the double line between the femoral neck and piriformis fossa is significantly associated with projection error. When double line widths exceed 5 mm, the risk of projection error greater than 10% is significantly increased compared to narrower double lines, and the acceptability rate for templating drops below 80% (p = 0.02). CONCLUSION: The double contour width is a potential landmark for excluding pelvic AP radiographs unsuitable for THA templating due to inaccurate femoral rotation.


Assuntos
Artroplastia de Quadril , Articulação do Quadril , Adulto , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
BMC Musculoskelet Disord ; 22(1): 369, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33879123

RESUMO

BACKGROUND: The effect of change in hip anatomy on change in gait pattern is not well described in current literature. Therefore, our primary aim was to describe and quantify changes in hip geometry and gait pattern 1 year after total hip arthroplasty (THA) in individuals with hip osteoarthritis. Our secondary aim was to explore the effect of postoperative change in femoral neck anteversion (FNA) and femoral offset and acetabular offset (FO/AO) quota on postoperative change in hip rotation and hip adduction moment during gait, respectively, 1 year after THA". METHODS: Sixty-five individuals with primary hip osteoarthritis, scheduled for THA, were analyzed in this prospective intervention study. Participants were evaluated pre- and 1 year postoperatively with computed tomography-scans, three-dimensional gait analysis, and patient-reported outcome measures. Multiple linear regressions were performed to evaluate the association between change in joint anatomy and change in gait pattern after THA. RESULTS: One year postoperatively, global offset was symmetrical between sides as a result of decreased acetabular offset and increased femoral offset on the operated side. Quality of overall gait pattern improved, and participants walked faster and with less trunk lean over the affected side. FNA and hip rotations during walking changed equally in external and internal directions after THA and change in hip rotation during walking was associated with change in FNA in the same direction. An increase in external hip adduction moments was, on the other hand, not associated with change in FO/AO quota but with a more upright walking position and increased walking speed. CONCLUSIONS: The findings of this study suggest that geometrical restoration during THA impacts postoperative gait pattern and, in addition to known factors such as FO, height of hip rotation center, and leg length discrepancy, the FNA must also be taken into consideration. TRIAL REGISTRATION: Trial registration: Clinicaltrial.gov , NCT01512550 , Registered 19 January 2012 - Retrospectively registered.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Marcha , Análise da Marcha , Articulação do Quadril/cirurgia , Humanos , Estudos Prospectivos
14.
Int Orthop ; 45(4): 923-929, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33442760

RESUMO

PURPOSE: The goal of total hip endoprosthesis is to achieve painless and functional hip for long term. Accurate reconstruction of hip anatomy largely depends on the implant design. In order to select an implant in correspondence with the native hip, the proximal femoral morphology has been in focus of many studies in the past years. The purpose of this study is to analyze proximal femoral geometry in the Croatian population by radiographic evaluation. METHODS: We conducted a retrospective study analyzing conventional radiographies of the hip, obtained within the last four years from the database of Clinic for Orthopaedic Surgery Lovran. The number of studied patients was 300,168 women and 132 men. The proximal femoral geometric parameters assessed were as follows: femoral head diameter, femoral neck length, neck-shaft angle, angle of femoral neck anteversion, and lateral femoral offset. The results obtained were compared between genders and with results of other studies. RESULTS: Proximal femoral anatomy differed in femoral head diameter and lateral femoral offset between males and females in our group of patients, while femoral neck length, femoral neck shaft angle, and femoral neck anteversion have shown similar values in both genders. Our study also showed specificity of the Croatian population in almost all parameters of proximal femoral anatomy, in comparison with other ethnic groups. CONCLUSION: Our results support the observation on high diversity in the morphology of the proximal femur and the specificity of the proximal femoral anatomy of the Croatian population.


Assuntos
Cabeça do Fêmur , Fêmur , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Colo do Fêmur , Humanos , Masculino , Próteses e Implantes , Estudos Retrospectivos
15.
Arch Orthop Trauma Surg ; 141(6): 891-897, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32474699

RESUMO

INTRODUCTION: Inaccurate stem implantation can cause unsatisfactory offset reconstruction and may result in insufficient gluteal muscle function or aseptic loosening. In this study, stem alignment of a collarless straight tapered HA-coated stem was retrospectively analyzed during the learning phase of the direct anterior approach (DAA) for primary total hip arthroplasty (THA). MATERIAL AND METHODS: From Jan 2013 to Jun 2015, a total of 93 cementless THA were implanted in patients with unilateral coxarthrosis via the DAA in a two surgeon setting using the Corail® or Trendhip® stem (DePuy Synthes or Aesculap). Varus(+)/Valgus(-) stem alignment was analyzed in postoperative anteroposterior pelvic radiographs. Effects on femoral offset reconstruction and correlation to patient's individual clinical and radiological parameters were evaluated. RESULTS: 55 stems were implanted in varus (59%), 32 in neutral (34%) and 6 in valgus alignment (7%). Mean stem alignment in varus position was + 2.2° (SD ± 1.4°). Varus alignment was associated with male gender and preoperative coxa vara deformity: low CCD, high femoral offset and long thigh neck (p ≤ 0.001). Alignment was not correlated to femoral offset restoration, BMI or leg length difference. Mean cup inclination was 44° (SD ± 4.7°) and 90% matched the coronal Lewinnek safe zone. CONCLUSION: In the learning curve, the DAA can be associated with a high incidence of varus stem alignment when using a straight tapered stem, especially in men with coxa vara deformity: low CCD, high femoral offset and long thigh neck. An insufficient capsule release makes femur exposure more difficult and might be an additional factor for this finding. We recommend intraoperative X-ray in the learning phase of the DAA to verify correct implant positioning and to adjust offset options.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Feminino , Humanos , Masculino , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Estudos Retrospectivos
16.
Knee Surg Sports Traumatol Arthrosc ; 28(9): 2808-2815, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31352496

RESUMO

PURPOSE: Biomechanical studies suggest that PF tracking is not reliably restored to physiological values in TKA despite surgical technique optimization. A clinical observation is that current TKA designs may not replicate anterior femoral offset. The aim was to examine the intraoperative resection thicknesses of the anterior femoral condyles during TKA and correlate these findings relative to modern prostheses. METHODS: This was a retrospective analysis of 199 patients who underwent 233 TKAs using a single implant design with measured anterior femoral condylar resection thicknesses. The aim was to restore posterior condylar offset whilst minimizing overstuffing of the anterior compartment of the knee by choosing the smallest prosthesis to allow for the maximal anterior resection as close to the cortex without inducing notching. Prosthetic measurements from 7 commonly used TKAs were collected by analysis of 3D models of median sized explants. RESULTS: An average of 7.9 mm (SD 2.5 mm, range 2-16.5 mm) and 11.5 mm (SD 2.5 mm, range 2-21 mm) was resected from the medial and lateral aspects of the anterior femur, respectively. The average anterior flange thickness for the prosthesis data set was 6.6 mm (SD 0.6 mm, range 6.1-7.9 mm) medially and 7.6 mm (SD 0.7 mm, range 6.8-9.0 mm) laterally. Comparison across patients who received the median prosthesis size of 5 (SD 1.3, range 2-8) was inadequately restored by 1.4 mm (p < 0.00001) medially and 3.4 mm (p < 0.00001) laterally. CONCLUSION: Host anatomy is not routinely restored during TKA. The surgical teaching to aim for an anterior femoral osteotomy close to the anterior cortex will result in understuffing of the PFJ and based on current prosthesis designs, the risk of overstuffing is not as significant as once believed. Future prostheses and surgical techniques should aim to restore not only posterior femoral but also anterior femoral offset. LEVEL OF EVIDENCE: IV, Case series.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Prótese do Joelho , Desenho de Prótese , Idoso , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
Knee Surg Sports Traumatol Arthrosc ; 28(9): 2998-3006, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31595340

RESUMO

PURPOSE: Approximately 10% of all patients that require a total knee arthroplasty present with valgus osteoarthritis (OA) of the knee. Valgus OA goes along with posterolateral bone loss and lateral soft tissue tightness. The role of malalignment on the development of OA is not fully understood. The current study investigates whether the femoral offset (FO), femoral mechanical-anatomical (FMA) angle, anatomical lateral distal femur angle (aLDFA), mechanical lateral distal femur angle (mLDFA), medial proximal femur angle (MPFA), medial proximal tibia angle (MPTA) or lateral distal tibia angle (LDTA) differ in patients with valgus OA of the knee. METHODS: FO, FMA angle, aLDFA, mLDFA, MPFA, MPTA and LDTA were assessed and compared between 100 consecutive knees with minimal valgus OA (50 male, 50 female) and 100 consecutive knees with minimal varus OA (50 male, 50 female). RESULTS: FO was significantly higher in males with valgus OA (p = 0.002) and females with varus OA (p = 0.01). The observed values for the FMA angle were significantly higher in males with valgus OA (p = 0.002) and females with varus OA (p = 0.041). The aLDFA and mLDFA were significantly smaller in all patients with valgus OA (p < 0.001). No differences between the varus and valgus groups were detected regarding MPFA (males: p = 0.052; females: p = 0.719). Tibial measurements showed significantly higher values for the MPTA (p < 0.001) in both valgus groups and no difference for LDTA (men: p = 0.139; women: p = 0.196). CONCLUSION: Bony alterations in the femoral anatomy seem to be more important than in the tibial anatomy. While in male patients with valgus OA, the main anatomic variation is the hypoplasia of the lateral femoral condyle, in females both decreased femoral offset of the hip as well as hypoplasia of the lateral condyle are present. LEVEL OF EVIDENCE: III.


Assuntos
Mau Alinhamento Ósseo/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Caracteres Sexuais
18.
Int Orthop ; 44(1): 45-51, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31254017

RESUMO

INTRODUCTION: In total hip arthroplasty (THA), altering the original offset can lead to poor outcome or even complications or revision when the changes are too great. The aim of the present study was to compare femoral offset between short and standard stems. The hypothesis was that the short stems studied provide better control of post-operative femoral offset. PATIENTS AND METHODS: We retrospectively reviewed 100 consecutive THAs using uncemented optimys™ short stems (Mathys, Bettlach, Switzerland), matched to 100 standard stem THAs performed during the same period. The primary endpoint was femoral offset; secondary endpoints were the limb length and cervico-diaphyseal angle. RESULTS: The mean femoral offset increased by 6.0 ± 7.2 mm overall (p < 0.0001), 4.7 ± 6.7 mm in the short-stem group (p < 0.0001), and 7.2 ± 7.5 mm in the standard stem group (p < 0.0001), with a significant inter-group difference (p = 0.0152). Limb length showed no significant inter-group difference (p = 0.8425). Cervico-diaphyseal angle was increased by surgery overall, and more by standard than by short stems (p < 0.05). CONCLUSION: Measurement of femoral offset revealed significant lateralization. It is critical that offset should be maintained in THA. The technique we use increases femoral offset, but the present study showed less increase using short than standard stems. These findings must be borne in mind to achieve good clinical outcome.


Assuntos
Artroplastia de Quadril/instrumentação , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Prótese de Quadril , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
19.
Arch Orthop Trauma Surg ; 140(6): 827-833, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32157370

RESUMO

INTRODUCTION: Computed tomography-based three-dimensional models may allow the accurate determination of the center of rotation, lateral and anterior femoral offsets, and the required implant size in total hip arthroplasty. In this cadaver study, the accuracy of anatomical reconstruction was evaluated using a three-dimensional planning tool. MATERIALS AND METHODS: A total of eight hip arthroplasties were performed on four bilateral specimens. Based on a computed tomography scan, the position and size of the prosthesis were templated with respect to the anatomical conditions. RESULTS: On average, all parameters were reconstructed to an accuracy of 4.5 mm and lie within the limits recommended in the literature. All prostheses were implanted with the templated size. CONCLUSIONS: The exact anatomy of the patient and the required size and position of the prosthesis were precisely analyzed using a templating software. Based on the present findings, the development of template-directed instrumentation is conceivable using this method. However, further technical features (e.g., navigation or robot-assisted surgery) are required for improved precision for implant positioning.


Assuntos
Artroplastia de Quadril , Articulação do Quadril , Imageamento Tridimensional , Modelagem Computacional Específica para o Paciente , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Tomografia Computadorizada por Raios X
20.
Eur J Orthop Surg Traumatol ; 30(8): 1463-1470, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32613469

RESUMO

INTRODUCTION: Accurate reconstruction of biomechanical parameters following total hip arthroplasty (THA) is crucial for good joint function. We investigated how reconstruction parameters achieved by minimally invasive anterior (MIS) THA may influence function and patient-related outcomes. METHODS: A consecutive series of 95 patients treated by MIS THA for primary osteoarthritis were retrospectively reviewed. Primary outcome measures were Harris Hip Score (HHS), hip disability and osteoarthritis outcome score (HOOS) and EQ-5D. Femoral offset (FO), abductor lever arm (ALA), centre of rotation (CoR), leg length discrepancy (LLD), cup version and stem alignment were measured pre- and post-operatively. Obtained reconstruction parameters compared to the contralateral hip were used as independent variables in a multivariate regression with each primary outcome measure as dependent variable. RESULTS: Mean age at surgery was 69 years. HHS rated 94.7% of patients as good/excellent and mean EQ-5D was 0.82. Post-operative HOOS subscales showed no statistical difference compared to the Italian benchmark population. Stem alignment averaged 0.2° valgus, mean cup inclination was 37.8° and mean anteversion was 12.8°. When compared to the contralateral side, CoR was post-operatively elevated by 2.6 mm and medialized by 2.4 mm averagely. An average FO reduction of -0.5 mm was observed while FO ratio increased by 1.9% averagely. ALA decreased by -3.3 mm while LLD was 2.3 mm averagely. Multivariate regression analysis revealed a significant contribution of ALA to HHS only. CONCLUSIONS: Biomechanical parameters achieved by MIS THA are satisfactory with negligible impact on functional results and no impact on patient-related outcomes certifying the high quality achieved in THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite do Quadril , Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/cirurgia , Humanos , Desigualdade de Membros Inferiores , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA