Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 674
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(10): e2306508, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37919860

RESUMO

The design and fabrication of NO-evolving core-shell nanoparticles (denoted as NC@Fe), comprised of BNN6-laden COF@Fe3 O4 nanoparticles, are reported. This innovation extends to the modification of 3D printed polyetheretherketone scaffolds with NC@Fe, establishing a pioneering approach to multi-modal bone therapy tailored to address complications such as device-associated infections and osteomyelitis. This work stands out prominently from previous research, particularly those relying on the use of antibiotics, by introducing a bone implant capable of simultaneous NO gas therapy and photothermal therapy (PPT). Under NIR laser irradiation, the Fe3 O4 NP core (photothermal conversion agent) within NC@Fe absorbs photoenergy and initiates electron transfer to the loaded NO donor (BNN6), resulting in controlled NO release. The additional heat generated through photothermal conversion further propels the NC@Fe nanoparticles, amplifying the therapeutic reach. The combined effect of NO release and PPT enhances the efficacy in eradicating bacteria over a more extensive area around the implant, presenting a distinctive solution to conventional challenges. Thorough in vitro and in vivo investigations validate the robust potential of the scaffold in infection control, osteogenesis, and angiogenesis, emphasizing the timeliness of this unique solution in managing complicated bone related infectious diseases.


Assuntos
Estruturas Metalorgânicas , Polímeros , Benzofenonas , Polietilenoglicóis , Cetonas
2.
BMC Surg ; 24(1): 169, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811965

RESUMO

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Assuntos
Ligas , Benzofenonas , Análise de Elementos Finitos , Cetonas , Vértebras Lombares , Polietilenoglicóis , Polímeros , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Materiais Biocompatíveis
3.
Odontology ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717525

RESUMO

The purpose of this study was to analyze the biomechanical properties of implants made of different materials to replace missing teeth by using three-dimensional finite element analysis and provide a theoretic basis for clinical application. CBCT data was imported into the Mimics and 3-Matic to construct the three-dimensional finite element model of a missing tooth restored by an implant. Then, the model was imported into the Marc Mentat. Based on the variations of the implant materials (titanium, titanium-zirconia, zirconia and poly (ether-ether-ketone) (PEEK)) and bone densities (high and low), a total of eight models were created. An axial load of 150 N was applied to the crown of the implant to simulate the actual occlusal situation. Both the maximum values of stresses in the cortical bone and implant were observed in the Zr-low model. The maximum displacements of the implants were also within the normal range except for the PEEK models. The cancellous bone strains were mainly distributed in the apical area of the implant, and the maximum value (3225 µstrain) was found in PEEK-low model. Under the premise of the same implant material, the relevant data from various indices in low-density bone models were larger than that in high-density bone models. From the biomechanical point of view, zirconia, titanium and titanium-zirconia were all acceptable implant materials for replacing missing teeth and possessed excellent mechanical properties, while the application of PEEK material needs to be further optimized and modified.

4.
BMC Oral Health ; 24(1): 760, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965507

RESUMO

BACKGROUND: Preservation of the remaining structures while maintaining an esthetic appearance is a major objective in removable partial prosthodontics. So, the aim of the current study was to compare the stresses induced on the supporting structures by two digitally produced esthetic core materials; Zirconia and Polyetheretherketone when used as an extracoronal attachment in distal extension removable partial dentures using strain gauge analysis. METHODS: A mandibular Kennedy class II stone cast with the necessary abutments' preparations was scanned. The mandibular left canine and first premolar teeth were virtually removed. An acrylic mandibular left canine and first premolar teeth were prepared with heavy chamfer finish line and scanned. Virtual superimposition of the acrylic teeth in their corresponding positions was done. Two strain gauge slots were designed: distal to the terminal abutment and in the residual ridge. Two models and two sets of scanned teeth were digitally printed. The printed teeth were then placed in their corresponding sockets in each model and scanned. The attachment design was selected from the software library and milled out of Zirconia in the model ZR and Polyetheretherketone in the model PE. Five removable partial dentures were constructed for each model. The strain gauges were installed in their grooves. A Universal testing machine was used for unilateral load application of 100 N (N). For each removable partial denture, five measurements were made. The data followed normal distribution and were statistically analyzed by using unpaired t test. P value < 0.05 was considered to be statistically significant. RESULTS: During unilateral loading unpaired t test showed statistically significant difference (p = 0.0001) in the microstrain values recorded distal to the abutment between the models ZR (-1001.6 µÎµ ± 24.56) and PE (-682.6 µÎµ ± 22.18). However, non statistically significant difference (p = 0.3122) was observed in the residual ridge between them; ZR (16.2 µÎµ ± 4.53) and PE (15 µÎµ ± 3.74). CONCLUSIONS: In removable partial dentures, Polyetheretherketone extracoronal attachment induces less stress on the supporting abutments compared to the zirconia one with no difference in the stresses induced by them on the residual ridge.


Assuntos
Benzofenonas , Planejamento de Dentadura , Prótese Parcial Removível , Cetonas , Polímeros , Zircônio , Cetonas/química , Humanos , Zircônio/química , Polietilenoglicóis , Análise do Estresse Dentário , Materiais Dentários/química , Desenho Assistido por Computador , Dente Suporte , Estresse Mecânico , Estética Dentária , Teste de Materiais
5.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702708

RESUMO

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Estética Dentária , Técnica para Retentor Intrarradicular , Humanos , Cerâmica , Análise do Estresse Dentário , Benzofenonas , Incisivo/lesões , Materiais Dentários/química , Polietilenoglicóis , Cetonas/química , Polímeros , Vidro , Teste de Materiais , Planejamento de Prótese Dentária
6.
BMC Oral Health ; 24(1): 904, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112986

RESUMO

BACKGROUND: Multi-rooted teeth with extensive dental defects often face challenges in stability and biomechanical failure. High-performance polymer PEEK materials, with properties closer to dentin, show promise in reducing stress concentration and preserving tooth structure. This report aimed to explore the use of a highly retentive polyetheretherketone (PEEK) for manufacturing custom-made split post and core for the restoration of grossly destroyed endodontically treated molars. CLINICAL CONSIDERATIONS: A 40-year-old female patient presented with complaints of loss of tooth substance in the posterior mandibular tooth. This case involved the digital design and fabrication of PEEK split post and core to restore multirooted molar with insufficient dental tissue remnants. The restorations were evaluated over a 3-year follow-up using the World Federation criteria (FDI). The restoration was clinically evaluated through intraoral examination, radiographic assessment, and subjective patient satisfaction, and was deemed clinically good according to FDI criteria. CONCLUSION: The outstanding mechanical properties of PEEK, coupled with the structure of the split post, provide an effective treatment option for weakened multirooted teeth. Simultaneously, the restoration configuration effectively addressed the challenge of varying postinsertion directions, and the interlocking mechanism between the primary and auxiliary posts enhanced the stability of the post and core.


Assuntos
Benzofenonas , Cetonas , Dente Molar , Polietilenoglicóis , Polímeros , Humanos , Feminino , Adulto , Dente Molar/cirurgia , Técnica para Retentor Intrarradicular , Seguimentos , Planejamento de Prótese Dentária , Dente não Vital/cirurgia , Desenho Assistido por Computador
7.
J Pak Med Assoc ; 74(2): 282-286, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419227

RESUMO

OBJECTIVE: To evaluate the influence of polyether ether ketone coping crown on the adaptation of implant abutment. Methods: The vitro study was conducted at the department of Prosthodontics, Hainan Stomatological Hospital, China, from October 2021 to March 2022, and comprised patients undergoing implant surgery on first molar. Patients were divided into two groups, with group A patients receiving polyether ether ketone coping crowns, and group B receiving zirconia crowns. Replica technique was used to replicate the gap between the crowns and the abutments. The thickness of the silicone film was measured under the stereomicroscope, and the gap between the groups was compared. Data was analysed using SPSS 22. RESULTS: In group A, mean marginal gap was 82.43±25.00µm, and mean overall gap was 85.45±33.75µm. In group B, the corresponding values were 65.09±11.69µm and 78.04±26.67µm. There was a significant difference in the adaptation between the groups at the marginal and overall measurement points (p<0.05). Conclusion: Marginal and internal adaptations of polyether ether ketone coping crown for abutment could be considered clinically acceptable.


Assuntos
Benzofenonas , Cetonas , Polietilenoglicóis , Polímeros , Humanos , Adaptação Psicológica , Éteres
8.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 251-256, 2024 May 30.
Artigo em Zh | MEDLINE | ID: mdl-38863089

RESUMO

Polyetheretherketone (PEEK) has emerged as a thermoplastic material of choice in the realm of implantable medical devices, owing to its high biocompatibility and exceptional mechanical strength. Despite its promise for custom-made medical devices, 3D-printed PEEK in orthopedics, trauma, and spinal implants has not yet achieved widespread application. This study outlines the properties of PEEK, 3D-printed PEEK-based composites, and their utilization in implantable medical devices, thereby fostering the development and regulation of next-generation medical devices.


Assuntos
Benzofenonas , Materiais Biocompatíveis , Cetonas , Polietilenoglicóis , Polímeros , Impressão Tridimensional , Próteses e Implantes , Humanos
9.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 237-244, 2024 May 30.
Artigo em Zh | MEDLINE | ID: mdl-38863087

RESUMO

Additive manufacturing (3D printing) technology aligns with the direction of precision and customization in future medicine, presenting a significant opportunity for innovative development in high-end medical devices. Currently, research and industrialization of 3D printed medical devices mainly focus on nondegradable implants and degradable implants. Primary areas including metallic orthopaedic implants, polyether-ether-ketone (PEEK) bone implants, and biodegradable implants have been developed for clinical and industrial application. Recent research achievements in these areas are reviewed, with a discussion on the additive manufacturing technologies and applications for customized implants. Challenges faced by different types of implants are analyzed from technological, application, and regulatory perspectives. Furthermore, prospects and suggestions for future development are outlined.


Assuntos
Impressão Tridimensional , Próteses e Implantes , Benzofenonas , Polímeros , Humanos , Cetonas , Desenho de Prótese , Materiais Biocompatíveis , Polietilenoglicóis , Implantes Absorvíveis
10.
BMC Musculoskelet Disord ; 24(1): 63, 2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36694169

RESUMO

BACKGROUND: Proximal humerus fractures are often treated with a fixed-angle titanium plate osteosynthesis. Recently, plates made of alternative materials such as carbon fibre-reinforced polyetheretherketone (CFR-PEEK) have been introduced. This study presents the postoperative results of patients treated with a CFR-PEEK plate. METHODS: Patients with proximal humerus fractures treated with a CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) were included. In follow-up examination, age and gender adjusted Constant-Murley Score (ACS), Subjective Shoulder Value (SSV), Quick Disabilities of the Arm, Shoulder and Hand Score (QDASH) and pain score (Visual Analog Scale (VAS)) were analyzed. General condition at follow-up was measured by European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-3L). Range of motion was recorded. In addition, radiographs at follow-up, unfavorable events and revision rate were analyzed. RESULTS: In total, 98 patients (66.0 ± 13.2 years, 74 females, 24 males) were reexamined. Mean follow-up was 27.6 ± 13.2 months. There were 15 2-part, 28 3-part and 55 4-part fractures. The functional scores showed good results: SSV 83.3 ± 15.6%, QDASH 13.1 ± 17.0 and ACS 80.4 ± 16.0. A 4-part-fracture, head split component, nonanatomic head shaft reposition and preoperative radiological signs of osteoarthritis were significant negative predictors for poorer clinical scores. Unfavourable events were observed in 27 patients (27.6%). Revision surgery was performed in 8 (8.2%) patients. Risk factors for an unfavourable event were female gender, age of 50 years and older, diabetes, affected dominant hand, 4-part fracture, head split and preoperative radiological signs of osteoarthritis. CONCLUSION: There are several advantages of the CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) such as the polyaxial screw placement and higher stability of locking screws. In summary, the CFR-PEEK plate osteosynthesis is a good alternative with comparable clinical results and some biomechanical advantages. Proximal humerus fractures show good clinical results after treatment with a CFR-PEEK plate. The revision rate and the risk of unfavorable events are not increased compared to conventional titanium plate osteosynthesis. LEVEL OF EVIDENCE: IV.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Titânio , Qualidade de Vida , Polímeros , Fibra de Carbono , Polietilenoglicóis , Cetonas , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Fraturas do Ombro/etiologia , Placas Ósseas/efeitos adversos , Fraturas do Úmero/etiologia , Resultado do Tratamento , Úmero/cirurgia
11.
J Artif Organs ; 26(2): 144-150, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35729412

RESUMO

This study used a rabbit model to investigate the osteocompatibility of Si3N4-coated carbon fiber-reinforced polyetheretherketone (CFRP) and hydroxyapatite (HA)-coated CFRP with antibiotics (vancomycin [VCM]) and antithrombotic drugs (polyvinylpyrrolidone [PVP]). HA-coated cylindrical CFRP implants were used as the controls (HA), and HA-coated implants treated with VCM and PVP were prepared (HA-VP) as the test groups; a cylindrical CFRP coated with Si3N4 was also prepared (SiN). Ten implants from each group were randomly inserted into the femoral diaphysis of rabbits. The pull-out test, radiological analysis using micro-computed tomography (µ-CT), and histological analysis were performed. The pull-out strength of the SiN group was lower than that of the HA group. µ-CT analysis revealed that the amount of bone formation around the implant in the SiN group was inferior to that in the HA group. Conversely, the HA-VP group had equivalent pull-out strength and bone formation as analyzed by µ-CT compared to the HA group. In conclusion, the additional surface treatment of the HA-coated CFRP with VCM and PVP provided sufficient bone fixation and formation.


Assuntos
Durapatita , Fibrinolíticos , Animais , Coelhos , Antibacterianos , Fibra de Carbono , Materiais Revestidos Biocompatíveis , Cetonas , Polietilenoglicóis , Próteses e Implantes , Titânio , Microtomografia por Raio-X
12.
Skeletal Radiol ; 52(3): 393-404, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35536358

RESUMO

Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) orthopedic implants are gaining popularity in oncologic applications as they offer many potential advantages over traditional metallic implants. From an imaging perspective, this instrumentation allows for improved evaluation of adjacent anatomic structures during radiography, computed tomography (CT), and magnetic resonance imaging (MRI). This results in improved postoperative surveillance imaging quality as well as easier visualization of anatomy for potential image-guided percutaneous interventions (e.g., pain palliation injections, or ablative procedures for local disease control). CFR-PEEK devices are also advantageous in radiation oncology treatment due to their decreased imaging artifact during treatment planning imaging and decreased dose perturbation during radiotherapy delivery. As manufacturing processes for CFR-PEEK materials continue to evolve and improve, potential orthopedic applications in the spine and appendicular skeleton increase. An understanding of the unique properties of CFR-PEEK devices and their impact on imaging is valuable to radiologists delivering care to orthopedic oncology patients in both the diagnostic and interventional settings. This multidisciplinary review aims to provide a comprehensive insight into the radiologic, surgical, and radiation oncology impact of these innovative devices.


Assuntos
Neoplasias da Coluna Vertebral , Humanos , Fibra de Carbono/química , Neoplasias da Coluna Vertebral/cirurgia , Polímeros , Benzofenonas , Polietilenoglicóis/química , Cetonas/química , Carbono/química
13.
Acta Neurochir (Wien) ; 165(4): 897-904, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36820888

RESUMO

PURPOSE: Radiolucent anterior and posterior implants by carbon fiber-reinforced polyetheretherketone (CFR PEEK) aim to improve treatment of primary and secondary tumors of the spine during the last years. The aim of this study was to evaluate clinical and radiological outcomes after dorsoventral instrumentation using a CFR PEEK implant in a cohort of patients representing clinical reality. METHODS: A total of 25 patients with tumor manifestation of the thoracic and lumbar spine underwent vertebral body replacement (VBR) using an expandable CFR PEEK implant between January 2021 and January 2022. Patient outcome, complications, and radiographic follow-up were analyzed. RESULTS: A consecutive series aged 65.8 ± 14.7 (27.6-91.2) years were treated at 37 vertebrae of tumor manifestation, including two cases (8.0%) of primary tumor as well as 23 cases (92.0%) of spinal metastases. Overall, 26 cages covering a median of 1 level (1-4) were implanted. Duration of surgery was 134 ± 104 (65-576) min, with a blood loss of 792 ± 785 (100-4000) ml. No intraoperative cage revision was required. Surgical complications were reported in three (12.0%) cases including hemothorax in two cases (one intraoperative, one postoperative) and atrophic wound healing disorder in one case. In two cases (8.0%), revision surgery was performed (fracture of the adjacent tumorous vertebrae, progressive construct failure regarding cage subsidence). No implant failure was observed. CONCLUSION: VBR using CFR PEEK cages represents a legitimate surgical strategy which opens a variety of improvements-especially in patients in need of postoperative radiotherapy of the spine and MRI-based follow-up examinations.


Assuntos
Neoplasias , Fusão Vertebral , Humanos , Fibra de Carbono , Corpo Vertebral , Resultado do Tratamento , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Polietilenoglicóis , Cetonas , Estudos Retrospectivos
14.
Acta Neurochir (Wien) ; 165(1): 135-144, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36471204

RESUMO

PURPOSE: The CaO-SiO2-P2O5-B2O3 glass-ceramic (BGS-7) spacer is a recently developed spacer that shows chemical bonding to bone with high mechanical stability. Further, this spacer achieves similar results to those of titanium cages. However, evidence regarding the advantages of the BGS-7 spacer is weak compared to polyetheretherketone (PEEK) cage. A randomized controlled trial is therefore warranted. The purpose of this study was to compare the radiographic and clinical efficacies and safety of the BGS-7 spacer compared to those of the PEEK cage in patients who underwent posterior lumbar interbody fusion (PLIF). METHODS: The 54 participants who required one- or two-level PLIF due to lumbar degenerative disorders were randomly assigned to receive a BGS-7 spacer or PEEK cage. Visual analog scale (VAS), Oswestry Disability Index (ODI), European Quality of Life-5 Dimensions (EQ-5D), and painDETECT score were evaluated before surgery and at 3, 6, and 12 months after surgery. The fusion rate, degree of osteolysis, cage migration, and subsidence around the cage (spacer) were evaluated on computer tomography (CT) images at 12 months after surgery. RESULTS: The 12-month fusion rates were 77.8% in the BGS-7 spacer group and 81.0% in the PEEK cage group, with no significant difference (p = 0.807). The result regarding the non-inferiority of BGS-7 spacer was inconclusive. The linear mixed model showed no significant intervention effect in VAS, ODI, EQ-5D, and painDETECT score at the 3-, 6-, or 12-month follow-up. In addition, we found no significant between-group differences in the extent of osteolysis, spacer migration. However, the subsidence around the cage was significantly lower in the BGS-7 spacer group. CONCLUSIONS: This trial found similar fusion rates, and clinicoradiographic outcomes between the BGS-7 spacer and PEEK cage for PLIF. However, the non-inferiority was inconclusive. Safety concerns regarding fracture and migration of the BGS-7 spacer must be considered. Thus, the BGS-7 spacer design for PLIF surgery should be modified before further clinical use.


Assuntos
Osteólise , Fusão Vertebral , Humanos , Dióxido de Silício , Estudos Prospectivos , Estudos de Viabilidade , Qualidade de Vida , Polietilenoglicóis , Cetonas , Cerâmica , Resultado do Tratamento , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia
15.
Lasers Med Sci ; 38(1): 95, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36995426

RESUMO

This study aimed to evaluate the effects of different surface modification methods on the surface roughness, contact angle, and bond strength of composite-veneer materials of polyether-ether-ketone (PEEK). Fifty-five specimens (n = 11) with a size of 7 × 7 × 2 mm were cut out from PEEK discs. The specimens were divided into five groups with different surface treatments: no treatment (NO) (control group), sulfuric acid (SA), plasma (P), femtosecond laser (FS), and Nd-YAG laser (NY). After the surface treatments, the specimens were checked for roughness, contact angle, and bond strength of the composite-veneer material. Data were analyzed with the Welch test for roughness, contact angle, and bond strength parameters. Individual Pearson correlation tests were executed for all surface treatment groups to determine any significant correlations among roughness, contact angle, and bond strength parameters (P < .001). Roughness, contact angle, and bond strength values were affected by surface modification methods (P < .001). In comparison to the control group, NY and FS treatments increased the surface roughness and bond strength; they also provided bond strength values comparable to the SA group. When the relationship between the variables was examined, no correlation was seen between roughness, contact angle, and bond strength values for the NY, SA, and control groups (P > .05); however, significant correlations were determined between the contact angle and surface roughness values for the P and FS groups (P < .05). Femtosecond and Nd-YAG laser treatments are viable surface modification alternatives to the sulfuric acid treatment for the PEEK material.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Molhabilidade , Propriedades de Superfície , Resinas Compostas/química , Teste de Materiais , Polietilenoglicóis/química , Cetonas/química , Lasers de Estado Sólido/uso terapêutico , Éteres , Resistência ao Cisalhamento
16.
Int J Mol Sci ; 24(21)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37958636

RESUMO

Recently, polyetheretherketone (PEEK) has shown promising dental applications. Surface treatment is essential for dental applications owing to its poor surface energy and wettability; however, no consensus on an effective treatment method has been achieved. In this study, we attempted to carboxylate PEEK sample surfaces via Friedel-Crafts acylation using succinic anhydride and AlBr3. The possibility of further chemical modifications using carboxyl groups was examined. The samples were subjected to dehydration-condensation reactions with 1H,1H-pentadecafluorooctylamine and N,N'-dicyclohexylcarbodiimide. Furthermore, the sample's surface properties at each reaction stage were evaluated. An absorption band in the 3300-3500 cm-1 wavenumber region was observed. Additionally, peak suggestive of COOH was observed in the sample spectra. Secondary modification diminished the absorption band in 3300-3500 cm-1 and a clear F1s signal was observed. Thus, Friedel-Crafts acylation with succinic anhydride produced carboxyl groups on the PEEK sample surfaces. Further chemical modification of the carboxyl groups by dehydration-condensation reactions is also possible. Thus, a series of reactions can be employed to impart desired chemical structures to PEEK surfaces.


Assuntos
Desidratação , Anidridos Succínicos , Humanos , Polietilenoglicóis/química , Cetonas/química , Propriedades de Superfície , Acilação
17.
Int J Mol Sci ; 24(16)2023 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-37628923

RESUMO

Polyetheretherketone (PEEK) is one of the most promising implant materials for hard tissues due to its similar elastic modulus; however, usage of PEEK is still limited owing to its biological inertness and low osteoconductivity. The objective of the study was to provide PEEK with the ability to sustain the release of growth factors and the osteogenic differentiation of stem cells. The PEEK surface was sandblasted and modified with polydopamine (PDA). Moreover, successful sandblasting and PDA modification of the PEEK surface was confirmed through physicochemical characterization. The gelatin hydrogel was then chemically bound to the PEEK by adding a solution of glutaraldehyde and gelatin to the surface of the PDA-modified PEEK. The binding and degradation of the gelatin hydrogel with PEEK (GPEEK) were confirmed, and the GPEEK mineralization was observed in simulated body fluid. Sustained release of bone morphogenetic protein (BMP)-2 was observed in GPEEK. When cultured on GPEEK with BMP-2, human mesenchymal stem cells (hMSCs) exhibited osteogenic differentiation. We conclude that PEEK with a gelatin hydrogel incorporating BMP-2 is a promising substrate for bone tissue engineering.


Assuntos
Gelatina , Osteogênese , Humanos , Hidrogéis , Preparações de Ação Retardada , Polietilenoglicóis/farmacologia , Diferenciação Celular
18.
BMC Oral Health ; 23(1): 546, 2023 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-37559037

RESUMO

BACKGROUND: Insufficient research has been conducted in the literature assessing the performance of zirconia and polyetheretherketone (PEEK) crowns in relation to the essential requirements of successful restorations, such as fracture resistance or margin adaptation. The purpose of this study was to evaluate the effect of the coping materials zirconia or PEEK with different fabrication techniques on the vertical marginal gap and fracture resistance of posterior crowns with composite veneering. METHODS: Ceramic copings (n = 18) restoring mandibular first molar were fabricated from zirconia (Zircon.x, Presidentdental, Germany), milled PEEK (PEEK CAD) (breCAM.BioHPP, Bredent, Germany) and pressed PEEK (PEEK Press) (BioHPP Granules, Bredent, Germany) six specimens each (n = 6). The copings were veneered with high impact polymer composite (HIPC) material (breCAM.HIPC, Bredent, Germany). The vertical marginal gap was captured under a magnification of 40X. Five equidistant marks on each surface of the die distinguished the points of measurement for a total of 20 readings per sample. The analysis was completed using an image analysis system (ImageJ 1.53t, National Institute of Health, USA). The specimens were loaded to failure at a crosshead speed of 1 mm/min and the load at failure was recorded to measure the fracture resistance. RESULTS: The marginal gap was analyzed using one-way ANOVA followed by Tukey's post hoc test. Fracture resistance was analyzed using Welch one-way ANOVA followed by the Games-Howell post hoc test. Marginal gap values showed a significant difference between the tested groups, with zirconia having significantly lower gap values (48.67 ± 11.98 µm) than both the PEEK CAD (108.00 ± 20.08 µm) and Press groups (108.00 ± 25.10 µm) (p < 0.001). However, the results of fracture resistance showed no significant difference (p = 0.06) with 1687.47 ± 253.29 N, 2156.82 ± 407.64 N, 2436.72 ± 725.93 N for zirconia, PEEK CAD, and Press, respectively. The significance level was p < 0.05. CONCLUSIONS: Zirconia framework crowns have a smaller vertical marginal gap than milled and pressed PEEK crowns. Crowns fabricated from zirconia, PEEK CAD, or PEEK Press frameworks and veneered with composite resin have comparable fracture resistance lower than the maximum biting force in the posterior region. CLINICAL RELEVANCE: Posterior crowns with zirconia frameworks are preferred over milled and pressed PEEK frameworks regarding margin adaptation, although all can safely survive the maximum occlusal forces without fracture.


Assuntos
Coroas , Porcelana Dentária , Humanos , Polietilenoglicóis , Cetonas , Adaptação Psicológica , Desenho Assistido por Computador , Teste de Materiais , Planejamento de Prótese Dentária
19.
BMC Oral Health ; 23(1): 543, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37550631

RESUMO

BACKGROUND: To study the effect of water storage (3 months) on the creep deformation of various CAD-CAM composite structures at the nanoscale and compare it to that at the macroscale. METHODS: Seven CAD-CAM blocks were investigated: five resin-composite blocks (RCB), one polymer-infiltrated ceramic network (PICN) block, and one ceramic-filled polyetheretherketone (PEEK) block. Specimens of each material (n = 6) were separated into two groups (n = 3) according to their storage conditions (24 h dry storage at 23˚C and 3 months storage in 37˚C distilled water). Nano-indentation creep measurements were undertaken (creep depth measured in µm) using a nanoindenter (Nanovea) equipped with Berkovich three-sided pyramidal diamond tip. The machine was set for the chosen parameters: a load of 20 gf, a pause of 20 s, and the material type. Thirty indentations on 3 samples were made for each material for each test. Data were analysed using two-way ANOVA followed by one-way ANOVA and Bonferroni post hoc tests and independent t-test (< 0.05) for comparisons between the materials. RESULTS: The nanoindentation creep depth after 24 h storage ranged from 0.09 to 0.33 µm and increased after 3 months storage in distilled water to between 0.28 and 3.46 µm. There was a statistically significant difference in nanoindentation creep behaviour between the two storage conditions for each investigated material (independent t-test) and between all materials (Bonferroni post hoc). There was a non-significant negative correlation between nanoindentation creep (µm) and filler weight% at 24 h dry storage but a significant correlation at 3 months of water storage. A further non-significant positive correlation between nanoindentation creep (µm) and bulk compressive creep (%) was found. CONCLUSION: The PICN material showed superior dimensional stability in terms of nanoindentation creep depth in both storage conditions. Other composite blocks showed comparable performance at 24 h dry condition, but an increased nanoindentation creep upon water storage.


Assuntos
Cerâmica , Água , Humanos , Teste de Materiais , Resinas Compostas/química , Desenho Assistido por Computador , Propriedades de Superfície
20.
BMC Oral Health ; 23(1): 944, 2023 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-38031148

RESUMO

BACKGROUND: Premature loss of primary molars can be treated with a band loop space maintainer (SM). However, fabricating a conventional band loop SM requires multiple clinical and laboratory procedures, which can potentially affect the accuracy of the SM. Moreover, the conventional SM is unable to fully restore masticatory function and maintain the vertical dimension of the edentulous space. In this current study, a fully digital workflow to fabricate a semi-rigid bridge SM made from polyetheretherketone (PEEK) has been described and evaluated for its clinical effectiveness. METHODS: A total of 15 children (eight males and seven females) between the ages of 4-8 years, who experienced the premature loss of a single primary molar, were included in this study. Digital impressions were taken using the CEREC CAD/CAM chair system and imported into CAD software to design the semi-rigid bridge SM, which was fabricated using PEEK block as the maintainer material. The digital SM was tried-in and bonded to the abutment with resin cement. The edentulous space was measured immediately after bonding (T0) and 1 month (T1), 3 months (T2), and 6 months (T3) after treatment. The periodontal condition and mobility of the SM and abutment were also examined. RESULTS: The use of digital impressions resulted in a decreased occurrence of the pharyngeal reflex. The digital semi-rigid bridge SM, fabricated with PEEK, was both convenient and aesthetically pleasing, and successfully restored the anatomy and masticatory function of the missing primary molar. None of the 15 semi-rigid bridge SMs or abutments became loose or fell off during the study, and only one child presented with gingivitis. Furthermore, the difference in the edentulous space at T0, T1, T2, and T3 was not statistically significant (all P > 0.05). CONCLUSIONS: The digital semi-rigid bridge SM fabricated with PEEK was clinically effective in maintaining the missing space and had advantages over the traditional band/crown loop SM.


Assuntos
Boca Edêntula , Polímeros , Criança , Masculino , Feminino , Humanos , Pré-Escolar , Polietilenoglicóis , Benzofenonas , Cetonas , Desenho Assistido por Computador , Dente Molar/cirurgia , Coroas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA