1.
Strahlenther Onkol ; 200(5): 418-424, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488899

RESUMO

PURPOSE: This study aimed to assess the margin for the planning target volume (PTV) using the Van Herk formula. We then validated the proposed margin by real-time magnetic resonance imaging (MRI). METHODS: An analysis of cone-beam computed tomography (CBCT) data from early glottic cancer patients was performed to evaluate organ motion. Deformed clinical target volumes (CTV) after rigid registration were acquired using the Velocity program (Varian Medical Systems, Palo Alto, CA, USA). Systematic (Σ) and random errors (σ) were evaluated. The margin for the PTV was defined as 2.5 Σ + 0.7 σ according to the Van Herk formula. To validate this margin, we accrued healthy volunteers. Sagittal real-time cine MRI was conducted using the ViewRay system (ViewRay Inc., Oakwood Village, OH, USA). Within the obtained sagittal images, the vocal cord was delineated. The movement of the vocal cord was summed up and considered as the internal target volume (ITV). We then assessed the degree of overlap between the ITV and the PTV (vocal cord plus margins) by calculating the volume overlap ratio, represented as (ITV∩PTV)/ITV. RESULTS: CBCTs of 17 early glottic patients were analyzed. Σ and σ were 0.55 and 0.57 for left-right (LR), 0.70 and 0.60 for anterior-posterior (AP), and 1.84 and 1.04 for superior-inferior (SI), respectively. The calculated margin was 1.8 mm (LR), 2.2 mm (AP), and 5.3 mm (SI). Four healthy volunteers participated for validation. A margin of 3 mm (AP) and 5 mm (SI) was applied to the vocal cord as the PTV. The average volume overlap ratio between ITV and PTV was 0.92 (range 0.85-0.99) without swallowing and 0.77 (range 0.70-0.88) with swallowing. CONCLUSION: By evaluating organ motion by using CBCT, the margin was 1.8 (LR), 2.2 (AP), and 5.3 mm (SI). The margin acquired using CBCT fitted well in real-time cine MRI. Given that swallowing during radiotherapy can result in a substantial displacement, it is crucial to consider strategies aimed at minimizing swallowing and related motion.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Glote , Neoplasias Laríngeas , Imagem Cinética por Ressonância Magnética , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Imagem Cinética por Ressonância Magnética/métodos , Glote/diagnóstico por imagem , Masculino , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/radioterapia , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Movimentos dos Órgãos , Sistemas Computacionais , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Clin Densitom ; 27(3): 101504, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38897133

RESUMO

BACKGROUND: Weight bearing computed tomography (WBCT) utilizes cone beam CT technology to provide assessments of lower limb joint structures while they are functionally loaded. Grey-scale values indicative of X-ray attenuation that are output from cone beam CT are challenging to calibrate, and their use for bone mineral density (BMD) measurement remains debatable. To determine whether WBCT can be reliably used for cortical and trabecular BMD assessment, we sought to establish the accuracy of BMD measurements at the knee using modern WBCT by comparing them to measurements from conventional CT. METHODS: A hydroxyapatite phantom with three inserts of varying densities was used to systematically quantify signal uniformity and BMD accuracy across the acquisition volume. We evaluated BMD in vivo (n = 5, female) using synchronous and asynchronous calibration techniques in WBCT and CT. To account for variation in attenuation along the height (z-axis) of acquisition volumes, we tested a height-dependent calibration approach for both WBCT and CT images. RESULTS: Phantom BMD measurement error in WBCT was as high as 15.3% and consistently larger than CT (up to 5.6%). Phantom BMD measures made under synchronous conditions in WBCT improved measurement accuracy by up to 3% but introduced more variability in measured BMD. We found strong correlations (R = 0.96) as well as wide limits of agreement (-324 mgHA/cm3 to 183 mgHA/cm3) from Bland-Altman analysis between WBCT and CT measures in vivo that were not improved by height-dependent calibration. CONCLUSION: Whilst BMD accuracy from WBCT was found to be dependent on apparent density, accuracy was independent of the calibration technique (synchronous or asynchronous) and the location of the measurement site within the field of view. Overall, we found strong correlations between BMD measures from WBCT and CT and in vivo measures to be more accurate in trabecular bone regions. Importantly, WBCT can be used to distinguish between anatomically relevant differences in BMD, however future work is necessary to determine the repeatability and sensitivity of BMD measures in WBCT.

3.
Respiration ; 103(3): 146-154, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38402862

RESUMO

INTRODUCTION: The investigation of peripheral pulmonary lesions (PPLs) can be challenging. Several bronchoscopic modalities have been developed to reach and biopsy PPL but the level of adoption of these techniques by interventional pulmonologists (IPs) is unknown. This international survey was conducted to describe current practices in PPL investigation among IP. METHODS: This survey was sent to all members of the World Association for Bronchology and Interventional Pulmonology, Canadian Thoracic Society Procedures Assembly, AABIP, and the Groupe d'Endoscopie Thoracique et Interventionnel Francophone. The survey was composed of 48 questions and three clinical cases to establish a portrait of modalities used to investigate and treat PPL by IP around the world. RESULTS: Three hundred and twelve IP responded to the survey. Most of them practice in Europe (n = 122), North America (n = 97), and Asia (n = 49). Half of responders perform more than 100 endoscopic procedures for PPL annually. General anesthesia and conscious sedation are used in similar proportions (53% and 47%, respectively). Rapid on site evaluation (ROSE) is used when sampling PPL by 42%. Radial EBUS (69%), fluoroscopy (55%), and electromagnetic navigation (27%) are the most widely used techniques. Most IP combine techniques (89%). Robotic bronchoscopy (15%) and cone-beam CT (8%) are almost exclusively used in the USA where, respectively, 60% and 37% of respondents reported using these modalities. Ten percent of IP currently had access to endoscopic treatment modalities for PPL. However, half of the remaining IP plan to acquire an endoscopic treatment modality in the next 2 years. CONCLUSION: Available techniques and practices worldwide vary significantly regarding PPL investigation and treatment.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Humanos , Pneumopatias/patologia , Neoplasias Pulmonares/patologia , Broncoscopia/métodos , Canadá , Inquéritos e Questionários
4.
Lung ; 202(1): 73-81, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38129333

RESUMO

PURPOSE: Determining the cause of interstitial lung disease (ILD) remains challenging. While surgical lung biopsy remains the gold standard approach, risks associated with it may be prohibitive. Transbronchial lung cryobiopsy (TBLC) is a minimally invasive alternative with an improved safety profile and acceptable diagnostic accuracy. We retrospectively assessed whether the use of Cone Beam computed tomography guidance for TBLC (TBLC-CBCT) improves safety and diagnostic yield compared to performing TBLC with fluoroscopic guidance (TBLC-F). METHODS: A retrospective cohort review of 120 patients presenting for evaluation of newly diagnosed ILD was performed. Demographic data, pulmonary function test values, chest imaging pattern, procedural information, and final multidisciplinary discussion (MDD) diagnosis were recorded. RESULTS: 62 patients underwent TBLC-F and 58 underwent TBLC-CBCT. Patients undergoing TBLC-CBCT were older (67.86 ± 10.97 vs 61.45 ± 12.77 years, p = 0.004) and had a higher forced vital capacity percent predicted (73.80 ± 17.32% vs 66.00 ± 17.45%, p = 0.03) compared to the TBLC-F group. The average probe-to-pleura distance was 5.1 ± 2.3 mm in the TBLC-CBCT group with 4.0 ± 0.3 CBCT spins performed. Pneumothorax occurred more often in the TBLC-F group (n = 6, 9.7%) compared to the TBLC-CBCT group (n = 1, 1.7%, p = 0.06). Grade 2 bleeding only occurred in the TBLC-F group (n = 4, 6.5%). A final MDD diagnosis was obtained in 89% (n = 57) of TBLC-F patients and 95% (n = 57) of TBLC-CBCT patients. CONCLUSIONS: TBLC-CBCT appears to be safer compared to TBLC-F with both approaches facilitating an MDD diagnosis. Further studies from multiple institutions randomizing patients to each modality are needed to confirm these findings.


Assuntos
Biópsia , Doenças Pulmonares Intersticiais , Humanos , Biópsia/efeitos adversos , Biópsia/métodos , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Pulmonares Intersticiais/diagnóstico , Estudos Retrospectivos
5.
BMC Med Imaging ; 24(1): 34, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321390

RESUMO

BACKGROUND: Cone-beam computed tomography (CBCT) has been introduced for breast-specimen imaging to identify a free resection margin of abnormal tissues in breast conservation. As well-known, typical micro CT consumes long acquisition and computation times. One simple solution to reduce the acquisition scan time is to decrease of the number of projections, but this method generates streak artifacts on breast specimen images. Furthermore, the presence of a metallic-needle marker on a breast specimen causes metal artifacts that are prominently visible in the images. In this work, we propose a deep learning-based approach for suppressing both streak and metal artifacts in CBCT. METHODS: In this work, sinogram datasets acquired from CBCT and a small number of projections containing metal objects were used. The sinogram was first modified by removing metal objects and up sampling in the angular direction. Then, the modified sinogram was initialized by linear interpolation and synthesized by a modified neural network model based on a U-Net structure. To obtain the reconstructed images, the synthesized sinogram was reconstructed using the traditional filtered backprojection (FBP) approach. The remaining residual artifacts on the images were further handled by another neural network model, ResU-Net. The corresponding denoised image was combined with the extracted metal objects in the same data positions to produce the final results. RESULTS: The image quality of the reconstructed images from the proposed method was improved better than the images from the conventional FBP, iterative reconstruction (IR), sinogram with linear interpolation, denoise with ResU-Net, sinogram with U-Net. The proposed method yielded 3.6 times higher contrast-to-noise ratio, 1.3 times higher peak signal-to-noise ratio, and 1.4 times higher structural similarity index (SSIM) than the traditional technique. Soft tissues around the marker on the images showed good improvement, and the mainly severe artifacts on the images were significantly reduced and regulated by the proposed. CONCLUSIONS: Our proposed method performs well reducing streak and metal artifacts in the CBCT reconstructed images, thus improving the overall breast specimen images. This would be beneficial for clinical use.


Assuntos
Aprendizado Profundo , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Microtomografia por Raio-X , Algoritmos
6.
BMC Pulm Med ; 24(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218792

RESUMO

OBJECTIVE: This study aimed to assess the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after percutaneous transthoracic lung biopsy (PTLB) guided by C-arm cone-beam computed tomography (CBCT). Furthermore, this study aimed to examine the relationships between PTX and PH with demographics, clinical characteristics, imaging, and PTLB parameters. METHODS: A retrospective analysis was conducted on 192 patients who underwent PTLB at our hospital between January 2019 and October 2022. Incidences of PTX and PH were recorded. PTX was considered clinically significant if treated with chest tube insertion (CTI), and PH if treated with bronchoscopes or endovascular treatments. The various factors on PTX and PH were analyzed using the Chi-squared test and Student t-test. Logistic regression analyses were then used to determine these factors on the correlation to develop PTX and PH. RESULTS: PTX occurred in 67/192 cases (34.9%); CTI was required in 5/67 (7.5%). PH occurred in 63/192 cases (32.8%) and none of these cases required bronchoscopes or endovascular treatments. Lesion diameter (ORPTX = 0.822; ORPH = 0.785), presence of pulmonary emphysema (ORPH = 2.148), the number of samples (ORPH = 1.834), the use of gelfoam (ORPTX = 0.474; ORPH = 0.341) and ablation (ORPTX = 2.351; ORPH = 3.443) showed statistically significant correlation to PTX and PH. CONCLUSIONS: CBCT-guided PTLB is a safe and effective method for performing lung biopsies. The use of gelfoam has been shown to reduce the occurrence of PTX and PH. However, caution should be exercised when combining radiofrequency ablation with PTLB, as it may increase the risk of PTX and PH.


Assuntos
Pneumopatias , Pneumotórax , Humanos , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/patologia , Incidência , Estudos Retrospectivos , Relevância Clínica , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/epidemiologia , Pneumopatias/complicações , Tomografia Computadorizada de Feixe Cônico , Hemorragia/epidemiologia , Hemorragia/etiologia , Biópsia por Agulha/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Fatores de Risco
7.
BMC Pulm Med ; 24(1): 146, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509516

RESUMO

OBJECTIVE: Transbronchial biopsy is a safe manner with fewer complications than percutaneous transthoracic needle biopsy; however, the current diagnostic yield is still necessitating further improvement. We aimed to evaluate the diagnostic yield of using virtual bronchoscopic navigation (VBN) and cone-beam CT (CBCT) for transbronchial biopsy and to investigate the factors that affected the diagnostic sensitivity. METHODS: We retrospectively investigated 255 patients who underwent VBN-CBCT-guided transbronchial biopsy at our two centers from May 2021 to April 2022. A total of 228 patients with final diagnoses were studied. Patient characteristics including lesion size, lesion location, presence of bronchus sign, lesion type and imaging tool used were collected and analyzed. Diagnostic yield was reported overall and in groups using different imaging tools. RESULTS: The median size of lesion was 21 mm (range of 15.5-29 mm) with 46.1% less than 2 cm in diameter. Bronchus sign was present in 87.7% of the patients. The overall diagnostic yield was 82.1%, and sensitivity for malignancy was 66.3%. Patients with lesion > 2 cm or with bronchus sign were shown to have a significantly higher diagnostic yield. Four patients had bleeding and no pneumothorax occurred. CONCLUSION: Guided bronchoscopy with VBN and CBCT was an effective diagnostic method and was associated with a high diagnostic yield in a safe manner. In addition, the multivariant analysis suggested that lesion size and presence of bronchus sign could be a predictive factor for successful bronchoscopic diagnosis.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Biópsia/métodos , Tomografia Computadorizada de Feixe Cônico , Brônquios/patologia , Broncoscopia/métodos
8.
Skeletal Radiol ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38969781

RESUMO

Computed tomography (CT) is a common modality employed for musculoskeletal imaging. Conventional CT techniques are useful for the assessment of trauma in detection, characterization and surgical planning of complex fractures. CT arthrography can depict internal derangement lesions and impact medical decision making of orthopedic providers. In oncology, CT can have a role in the characterization of bone tumors and may elucidate soft tissue mineralization patterns. Several advances in CT technology have led to a variety of acquisition techniques with distinct clinical applications. These include four-dimensional CT, which allows examination of joints during motion; cone-beam CT, which allows examination during physiological weight-bearing conditions; dual-energy CT, which allows material decomposition useful in musculoskeletal deposition disorders (e.g., gout) and bone marrow edema detection; and photon-counting CT, which provides increased spatial resolution, decreased radiation, and material decomposition compared to standard multi-detector CT systems due to its ability to directly translate X-ray photon energies into electrical signals. Advanced acquisition techniques provide higher spatial resolution scans capable of enhanced bony microarchitecture and bone mineral density assessment. Together, these CT acquisition techniques will continue to play a substantial role in the practices of orthopedics, rheumatology, metabolic bone, oncology, and interventional radiology.

9.
J Appl Clin Med Phys ; 25(5): e14329, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38497567

RESUMO

PURPOSE: Histotripsy is a nonionizing, noninvasive, and nonthermal focal tumor therapy. Cone-beam computed tomography (CBCT) guidance was developed for targeting tumors not visible on ultrasound. This approach assumes cavitation is formed at the geometrical focal point of the therapy transducer. In practice, the exact location might vary slightly between transducers. In this study, we present a phantom with an embedded target to evaluate CBCT-guided histotripsy accuracy and assess the completeness of treatments. METHODS: Spherical (2.8 cm) targets with alternating layers of agar and radiopaque barium were embedded in larger phantoms with similar layers. The layer geometry was designed so that targets were visible on pre-treatment CBCT scans. The actual histotripsy treatment zone was visualized via the mixing of adjacent barium and agar layers in post-treatment CBCT images. CBCT-guided histotripsy treatments of the targets were performed in six phantoms. Offsets between planned and actual treatment zones were measured and used for calibration refinement. To measure targeting accuracy after calibration refinement, six additional phantoms were treated. In a separate investigation, two groups (N = 3) of phantoms were treated to assess visualization of incomplete treatments ("undertreatment" group: 2 cm treatment within 2.8 cm tumor, "mistarget" group: 2.8 cm treatment intentionally shifted laterally). Treatment zones were segmented (3D Slicer 5.0.3), and the centroid distance between the prescribed target and actual treatment zones was quantified. RESULTS: In the calibration refinement group, a 2 mm offset in the direction of ultrasound propagation (Z) was measured. After calibration refinement, the centroid-to-centroid distance between prescribed and actual treatment volumes was 0.5 ± 0.2 mm. Average difference between the prescribed and measured treatment sizes in the incomplete treatment groups was 0.5 ± 0.7 mm. In the mistarget group, the distance between prescribed and measured shifts was 0.2 ± 0.1 mm. CONCLUSION: The proposed prototype phantom allowed for accurate measurement of treatment size and location, and the CBCT visible target provided a simple way to detect misalignments for preliminary quality assurance of CBCT-guided histotripsy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia
10.
Clin Anat ; 37(2): 185-192, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37638802

RESUMO

The purpose of this study is to compare the subjective and objective quality and confidence between conventional angiography with cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) for the preoperative evaluation of potential donors for living donor liver transplant. Seventeen patients undergoing preoperative donor evaluation for living donor liver transplantation that underwent angiography with CBCT and contrast-enhanced MRI for evaluation of hepatic vascular anatomy were included in the study. Four attending radiologists interpreted anonymized, randomized angiography with CBCT images and MRIs, rating the diagnostic quality and confidence of their interpretation (on a 3-point scale) for each element, as well as clinically relevant measurements. Overall, the readers rated the quality of angiography with CBCT to be higher than that of MRI (median [interquartile range] = 3 (2, 3) vs. 2 (1-3), p < 0.001) across all patients. Readers of angiography with CBCT had more confidence in their interpretations as an average of all elements evaluated than the MRI readers (3 (3) vs. 3 (2, 3), p < 0.001). When the same reader interpreted both MRI and CBCT, the right hepatic artery diameter (3.8 mm ± 0.72 mm vs. 4.5 mm ± 1.2 mm, p < 0.005) and proper hepatic artery diameter (4.43 mm ± 0.98 mm vs. 5.4 mm ± 1.05 mm, p < 0.003) were significantly different between MRI and CBCT. There was poor interrater reliability for determining segment IV arterial supply for both modalities (κ < 0.2). Angiography with CBCT provides higher subjective diagnostic quality and greater radiologist confidence than MRI. The difference in measurements between CBCT and MRI when the same reader reads both studies suggests CBCT adds additional information over MRI evaluation alone.


Assuntos
Transplante de Fígado , Humanos , Doadores Vivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Angiografia , Tomografia Computadorizada de Feixe Cônico/métodos
11.
Dentomaxillofac Radiol ; 53(5): 316-324, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38627247

RESUMO

OBJECTIVES: Preoperative diagnosis of oral ameloblastoma (AME) and odontogenic keratocyst (OKC) has been a challenge in dentistry. This study uses radiomics approaches and machine learning (ML) algorithms to characterize cone-beam CT (CBCT) image features for the preoperative differential diagnosis of AME and OKC and compares ML algorithms to expert radiologists to validate performance. METHODS: We retrospectively collected the data of 326 patients with AME and OKC, where all diagnoses were confirmed by histopathologic tests. A total of 348 features were selected to train six ML models for differential diagnosis by a 5-fold cross-validation. We then compared the performance of ML-based diagnoses to those of radiologists. RESULTS: Among the six ML models, XGBoost was effective in distinguishing AME and OKC in CBCT images, with its classification performance outperforming the other models. The mean precision, recall, accuracy, F1-score, and area under the curve (AUC) were 0.900, 0.807, 0.843, 0.841, and 0.872, respectively. Compared to the diagnostics by radiologists, ML-based radiomic diagnostics performed better. CONCLUSIONS: Radiomic-based ML algorithms allow CBCT images of AME and OKC to be distinguished accurately, facilitating the preoperative differential diagnosis of AME and OKC. ADVANCES IN KNOWLEDGE: ML and radiomic approaches with high-resolution CBCT images provide new insights into the differential diagnosis of AME and OKC.


Assuntos
Ameloblastoma , Tomografia Computadorizada de Feixe Cônico , Aprendizado de Máquina , Cistos Odontogênicos , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Ameloblastoma/diagnóstico por imagem , Ameloblastoma/cirurgia , Ameloblastoma/patologia , Cistos Odontogênicos/diagnóstico por imagem , Cistos Odontogênicos/cirurgia , Estudos Retrospectivos , Feminino , Masculino , Diagnóstico Diferencial , Adulto , Pessoa de Meia-Idade , Algoritmos , Adolescente , Idoso , Neoplasias Maxilomandibulares/diagnóstico por imagem , Neoplasias Maxilomandibulares/cirurgia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiômica
12.
J Neuroradiol ; 51(2): 224-229, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262518

RESUMO

The increasing use of embolization devices with suboptimal radio-opacity to treat intracranial aneurysm underscores the need for advanced imaging techniques to characterize device-vessel interactions more accurately. Contrast-diluted cone-beam CT is commonly used in neurointervention but requires additional technical refinements to improve endovascular treatment assessment. In this technical note, we describe the virtual dilution cone beam CT (VDCBCT), a technique that synthetizes non-contrast and contrast-enhanced CBCT images to virtually dilute iodinated contrast agents, thereby facilitating a more accurate assessment of embolization device apposition. Through a set of intracranial aneurysms treated with different embolization devices, we describe the VDCBCT protocol and its usefulness for device apposition confidence. VDCBCT may enhance the global understanding of neurovascular embolization treatments by providing improved visualization of target vessels and low-radio-opacity embolization devices, obviating the need for contrast dilution.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Tomografia Computadorizada de Feixe Cônico/métodos , Meios de Contraste , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Resultado do Tratamento
13.
AJR Am J Roentgenol ; 221(1): 92-101, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37095661

RESUMO

Digital flat-panel detector cone-beam CT (CBCT), introduced in the early 2000s, was historically used in interventional radiology primarily for liver-directed therapies. However, contemporary advanced imaging applications, including enhanced needle guidance and augmented fluoroscopy overlay, have evolved substantially over the prior decade and now work synergistically with CBCT guidance to overcome limitations encountered with other imaging modalities. CBCT with advanced imaging applications has become increasingly used to facilitate a broad range of minimally invasive procedures, particularly relating to pain and musculoskeletal interventions. Potential advantages of CBCT with advanced imaging applications include greater accuracy for complex needle paths, improved targeting in the presence of metal artifact, enhanced visualization during injection of contrast medium or cement, increased ease when space in the gantry is limited, and reduced radiation doses versus conventional CT guidance. Nonetheless, CBCT guidance remains underutilized, partly relating to lack of familiarity with the technique. This article describes the practical implementation of CBCT with enhanced needle guidance and augmented fluoroscopy overlay and depicts the technique's application for an array of interventional radiology procedures, including epidural steroid injections, celiac plexus block and neurolysis, pudendal block, spine ablation, percutaneous osseous ablation fixation and osteoplasty, biliary recanalization, and transcaval type II endoleak repair.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiologia Intervencionista , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Coluna Vertebral/cirurgia , Agulhas , Fluoroscopia/métodos , Radiografia Intervencionista/métodos
14.
BMC Med Imaging ; 23(1): 46, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36978007

RESUMO

BACKGROUND: The aim of the study is to determine the distribution, location, diameter, and distance measurements of Canalis Sinusosus (CS) in relation with age and sex. METHODS: 300 Cone-Beam Computed Tomography (CBCT) images were evaluated. The distance between CS and nasal cavity floor (NCF), buccal cortical bone margin (BCM), alveolar ridge (AR), respectively.The presence of CS smaller than 1 mm, and the diameter of CS larger than 1 mm were determined. Accessory canals (AC) were classified according to their position relative to the teeth. RESULTS: 435 CS with a diameter of at least 1 mm and 142 CS < 1 mm were identified. The most frequently observed location of CS was the region of the right central incisors. The mean diameter of the canals ( CS ≥ 1) was 1.31 ± 0.19 on the right side and 1.29 ± 0.17 on the left side. No gender differences were found in canal diameter were observed (p > 0.05). There was no significant difference between men and women in the distance between CS and the NCF on the right side, and a significant difference was found in the distance of CS-NCF on the left side (p = 0.047). There were no significant differences between age groups in all parameters. CONCLUSION: CBCT is a useful tool for identifying CS. Location and diameter of ACs could not be associated with a specific age group or sex.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Maxila , Masculino , Humanos , Feminino , Estudos Retrospectivos , Maxila/diagnóstico por imagem , Processo Alveolar , Fatores Sexuais
15.
Orthod Craniofac Res ; 26(4): 576-584, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36912723

RESUMO

OBJECTIVES: To assess the skeletal and dental maxillary transverse compensation (yaw) on the cone beam computed tomography (CBCT) three-dimensional reconstructed image of the skull in two groups of patients, both clinically affected by a class III malocclusion with deviation of the lower midline. MATERIALS AND METHODS: An observational retrospective study was designed to analyse differences in two groups of patients, the first one was composed by patients affected by horizontal condylar hyperplasia, the second one by patients affected by dento-skeletal asymmetric class III malocclusion. Each group was composed by 15 patients. Transverse analysis was performed by measuring five landmarks (three bilateral and two uneven) with respect to a mid-sagittal plane; sagittal analysis was performed by measuring the sagittal distance on the mid-sagittal plane between bilateral points. Means were compared through inferential analysis. RESULTS: In the condylar hyperplasia group, all differences between the two sides were not statistically significant, nor for canines' difference (P = .0817), for molars (P = .1105) or for jugular points (.05871). In the class III group, the differences between the two sides were statistically significant for molars (P = .0019) and jugular points (P = .0031) but not for canines (P = .1158). Comparing the two groups, significant differences were found only for incisors' midline deviation (P = .0343) and canine (P = .0177). CONCLUSION: The study of the yaw on CBCT should be integrated into three-dimensional cephalometry and could help in differentiating the various malocclusion patterns.


Assuntos
Má Oclusão Classe III de Angle , Má Oclusão , Humanos , Estudos Retrospectivos , Hiperplasia/patologia , Má Oclusão/diagnóstico por imagem , Má Oclusão/patologia , Má Oclusão Classe III de Angle/diagnóstico por imagem , Má Oclusão Classe III de Angle/patologia , Maxila/diagnóstico por imagem , Maxila/patologia , Imageamento Tridimensional/métodos , Cefalometria/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula
16.
Pediatr Radiol ; 53(5): 963-970, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36720724

RESUMO

BACKGROUND: Percutaneous radiological gastrostomy tube insertion is a common procedure in children. An approach using ultrasound and fluoroscopy may not be feasible in patients with challenging anatomy; therefore, advanced techniques or other imaging modalities may be required. OBJECTIVE: To describe our experience using cone-beam computed tomography (CT)-assisted percutaneous gastrostomy insertion in pediatric patients with challenging anatomy. MATERIALS AND METHODS: A retrospective review was performed in children who underwent cone-beam CT-assisted percutaneous radiologic gastrostomy between January 2015 and July 2019. Indications, technique, outcomes, complications, and radiation dose (reference-point air kerma, air kerma area product) were assessed through chart and imaging review. Descriptive statistics only were used. RESULTS: Twenty-seven procedures were attempted in 26 patients. Reasons for utilizing cone-beam CT guidance were high-positioned stomach (n = 10), interposing bowel loops and liver (n = 19), omphalocele (n = 1), severe scoliosis (n = 1), and ventriculoperitoneal shunt (n = 1). Technical success was 85% (23/27). Mean procedure time was 96 min (range 50-131 min). No safe access route into the stomach was encountered in four patients; three were referred for surgical gastrostomy and one had a successful re-attempt. Radiation dose data was obtained from 19 procedures (17 successful) with a total dose in successful procedures ranging from 8.1 to 63.6 mGy (average 26.2 mGy, median 24.9 mGy). The number of cone-beam CT acquisitions per procedure ranged from 1 to 4. Major complication frequency was 11% (3/27) (bleeding, peritonitis, and aspiration pneumonia); minor complication frequency was 3.7% (1/27). CONCLUSION: This study shows that cone-beam CT guidance can be useful for assisting percutaneous radiologic gastrostomy in children with challenging anatomy.


Assuntos
Gastrostomia , Radiografia Intervencionista , Humanos , Criança , Gastrostomia/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Estômago , Fluoroscopia/métodos , Estudos Retrospectivos
17.
Skeletal Radiol ; 52(6): 1073-1088, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36350387

RESUMO

Weight bearing CT (WBCT) of the lower extremity is gaining momentum in evaluation of the foot/ankle and knee. A growing number of international studies use WBCT, which is promising for improving our understanding of anatomy and biomechanics during natural loading of the lower extremity. However, we believe there is risk of excessive enthusiasm for WBCT leading to premature application of the technique, before sufficiently robust protocols are in place e.g. standardised limb positioning and imaging planes, choice of anatomical landmarks and image slices used for individual measurements. Lack of standardisation could limit benefits from introducing WBCT in research and clinical practice because useful imaging information could become obscured. Measurements of bones and joints on WBCT are influenced by joint positioning and magnitude of loading, factors that need to be considered within a 3-D coordinate system. A proportion of WBCT studies examine inter- and intraobserver reproducibility for different radiological measurements in the knee or foot with reproducibility generally reported to be high. However, investigations of test-retest reproducibility are still lacking. Thus, the current ability to evaluate, e.g. the effects of surgery or structural disease progression, is questionable. This paper presents an overview of the relevant literature on WBCT in the lower extremity with an emphasis on factors that may affect measurement reproducibility in the foot/ankle and knee. We discuss the caveats of performing WBCT without consensus on imaging procedures and measurements.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Motivação , Humanos , Reprodutibilidade dos Testes , , Suporte de Carga
18.
Skeletal Radiol ; 52(12): 2387-2397, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37130960

RESUMO

OBJECTIVE: To assess test-retest reliability and correlation of weight-bearing (WB) and non-weight-bearing (NWB) cone beam CT (CBCT) foot measurements and Foot Posture Index (FPI) MATERIALS AND METHODS: Twenty healthy participants (age 43.11±11.36, 15 males, 5 females) were CBCT-scanned in February 2019 on two separate days on one foot in both WB and NWB positions. Three radiology observers measured the navicular bone position. Plantar (ΔNAVplantar) and medial navicular displacements (ΔNAVmedial) were calculated as a measure of foot posture changes under loading. FPI was assessed by two rheumatologists on the same two days. FPI is a clinical measurement of foot posture with 3 rearfoot and 3 midfoot/forefoot scores. Test-retest reproducibility was determined for all measurements. CBCT was correlated to FPI total and subscores. RESULTS: Intra- and interobserver reliabilities for navicular position and FPI were excellent (intraclass correlation coefficient (ICC) .875-.997). In particular, intraobserver (ICC .0.967-1.000) and interobserver reliabilities (ICC .946-.997) were found for CBCT navicular height and medial position. Interobserver reliability of ΔNAVplantar was excellent (ICC .926 (.812; .971); MDC 2.22), whereas the ΔNAVmedial was fair-good (ICC .452 (.385; .783); MDC 2.42 mm). Using all observers' measurements, we could calculate mean ΔNAVplantar (4.25±2.08 mm) and ΔNAVmedial (1.55±0.83 mm). We demonstrated a small day-day difference in ΔNAVplantar (0.64 ±1.13mm; p<.05), but not for ΔNAVmedial (0.04 ±1.13mm; p=n.s.). Correlation of WBCT (WB navicular height - ΔNAVmedial) with total clinical FPI scores and FPI subscores, respectively, showed high correlation (ρ: -.706; ρ: -.721). CONCLUSION: CBCT and FPI are reliable measurements of foot posture, with a high correlation between the two measurements.


Assuntos
, Postura , Masculino , Feminino , Humanos , Reprodutibilidade dos Testes , Pé/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Suporte de Carga
19.
Eur Arch Otorhinolaryngol ; 280(7): 3131-3140, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36604323

RESUMO

PURPOSE: Analysis of cochlear structures and postoperative temporal bone (TB) imaging are gaining importance in the evaluation of cochlear implantation (CI°). Our aims were to explore the microarchitecture of human cochlea using micro-computed tomography (µCT), analyze electrode's placement inside cochlea after CI°, and compare pre-/post-implantation µCT scans with cone-beam CT (CBCT) scans of same TBs. METHODS: Cadaveric TBs were scanned using µCT and CBCT then underwent CI° using straight electrodes. Thereafter, they underwent again µCT and CBCT-imaging. RESULTS: Ten TBs were studied. µCT allowed visualization of scala tympani, scala vestibuli, basilar membrane, osseous spiral lamina, crista fenestrae, and spiral ligament. CBCT showed same structures except spiral ligament and crista fenestrae. After CI°, µCT and CBCT displayed the scalar location and course of electrode array within the cochlea. There were 7 cases of atraumatic electrode insertion and 3 cases of insertion trauma: basilar membrane elevation, electrode foldover with limited migration into scala vestibuli, and electrode kinking with limited migration into scala vestibuli. Insertion trauma was not correlated with cochlea's size or crista's maximal height but with round window membrane diameter. Resolution of µCT was higher than CBCT but electrode artifacts were similar. CONCLUSIONS: µCT was accurate in visualizing cochlear structures, and course and scalar position of electrode array inside cochlea with any possible trauma to cochlea or array. CBCT offers a good alternative to µCT in clinical practice for cochlear imaging and evaluation of CI°, with lower radiation and higher resolution than multi-slice CT. Difficulties related to non-traumatic CI° are multifactorial.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Microtomografia por Raio-X , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Tomografia Computadorizada de Feixe Cônico , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia
20.
J Appl Clin Med Phys ; 24(1): e13783, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36208134

RESUMO

PURPOSE: Evaluate a cone-beam computed tomography (CBCT)-based daily adaptive platform in cervical cancer for multiple endpoints: (1) physics contouring accuracy of daily CTVs, (2) CTV coverage with adapted plans and reduced PTV margins versus non-adapted plans with standard-of-care (SOC) margins, (3) dosimetric improvements to CTV and organs-at-risk (OARs), and (4) on-couch time. METHODS AND MATERIALS: Using a Varian Ethos™ emulator and KV-CBCT scans, we simulated the doses 15 retrospective cervical cancer patients would have received with/without online adaptation for five fractions. We compared contours and doses from SOC plans (5-15 mm CTV-to-PTV margins) to adapted plans (3 mm margins). Auto-segmented CTVs and OARs were reviewed and edited by trained physicists. Physics-edited targets were evaluated by an oncologist. Time spent reviewing and editing auto-segmented structures was recorded. Metrics from the CTV (D99%), bowel (V45Gy, V40Gy), bladder (D50%), and rectum (D50%) were compared. RESULTS: The physician approved the physics-edited CTVs for 55/75 fractions; 16/75 required reductions, and 4/75 required CTV expansions. CTVs were encapsulated by unadapted, SOC PTVs for 56/75 (72%) fractions-representative of current clinical practice. CTVs were completely covered by adapted 3 mm PTVs for 71/75 (94.6%) fractions. CTV D99% values for adapted plans were comparable to non-adapted SOC plans (average difference of -0.9%), while all OAR metrics improved with adaptation. Specifically, bowel V45Gy and V40Gy decreased on average by 87.6 and 109.4 cc, while bladder and rectum D50% decreased by 37.7% and 35.8%, respectively. The time required for contouring and calculating an adaptive plan for 65/75 fractions was less than 20 min (range: 1-29 min). CONCLUSIONS: Improved dose metrics with daily adaption could translate to reduced toxicity while maintaining tumor control. Training physicists to perform contouring edits could minimize the time physicians are required at adaptive sessions improving clinical efficiency. All emulated adaptive sessions were completed within 30 min however extra time will be required for patient setup, image acquisition, and treatment delivery.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico Espiral , Neoplasias do Colo do Útero , Feminino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Estudos Retrospectivos , Estudos de Viabilidade , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA