Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Neurosci ; 44(13)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38302441

RESUMO

Ocular position drifts during gaze fixation are significantly less well understood than microsaccades. We recently identified a short-latency ocular position drift response, of ∼1 min arc amplitude, that is triggered within <100 ms by visual onsets. This systematic eye movement response is feature-tuned and seems to be coordinated with a simultaneous resetting of the saccadic system by visual stimuli. However, much remains to be learned about the drift response, especially for designing better-informed neurophysiological experiments unraveling its mechanistic substrates. Here we systematically tested multiple new feature tuning properties of drift responses. Using highly precise eye tracking in three male rhesus macaque monkeys, we found that drift responses still occur for tiny foveal visual stimuli. Moreover, the responses exhibit size tuning, scaling their amplitude (both up and down) as a function of stimulus size, and they also possess a monotonically increasing contrast sensitivity curve. Importantly, short-latency drift responses still occur for small peripheral visual targets, which additionally introduce spatially directed modulations in drift trajectories toward the appearing peripheral stimuli. Drift responses also remain predominantly upward even for stimuli exclusively located in the lower visual field and even when starting gaze position is upward. When we checked the timing of drift responses, we found it was better synchronized to stimulus-induced saccadic inhibition than to stimulus onset. These results, along with a suppression of drift response amplitudes by peristimulus saccades, suggest that drift responses reflect the rapid impacts of short-latency and feature-tuned visual neural activity on final oculomotor control circuitry in the brain.


Assuntos
Fixação Ocular , Visão Ocular , Animais , Masculino , Macaca mulatta , Movimentos Oculares , Movimentos Sacádicos , Percepção Visual/fisiologia
2.
J Neurosci ; 44(12)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38316562

RESUMO

With every saccadic eye movement, humans bring new information into their fovea to be processed with high visual acuity. Notably, perception is enhanced already before a relevant item is foveated: During saccade preparation, presaccadic attention shifts to the upcoming fixation location, which can be measured via behavioral correlates such as enhanced visual performance or modulations of sensory feature tuning. The coupling between saccadic eye movements and attention is assumed to be robust and mandatory and considered a mechanism facilitating the integration of pre- and postsaccadic information. However, until recently it had not been investigated as a function of saccade direction. Here, we measured contrast response functions during fixation and saccade preparation in male and female observers and found that the pronounced response gain benefit typically elicited by presaccadic attention is selectively lacking before upward saccades at the group level-some observers even showed a cost. Individual observer's sensitivity before upward saccades was negatively related to their amount of surface area in primary visual cortex representing the saccade target, suggesting a potential compensatory mechanism that optimizes the use of the limited neural resources processing the upper vertical meridian. Our results raise the question of how perceptual continuity is achieved and how upward saccades can be accurately targeted despite the lack of-theoretically required-presaccadic attention.


Assuntos
Movimentos Oculares , Movimentos Sacádicos , Masculino , Feminino , Humanos , Atenção/fisiologia , Fóvea Central , Percepção Visual/fisiologia , Estimulação Luminosa
3.
Ophthalmology ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38871087

RESUMO

PURPOSE: To examine the performance of self-reported visual difficulty (VD) in predicting objective visual impairment (VI) in older adults and explore factors that influence discordance. DESIGN: Cross-sectional analysis of the National Health and Aging Trends Study (2022). METHODS: Participants reporting blindness or difficulties with distance or near vision were characterized as having VD. Presenting binocular distance visual acuity (VA), near VA, and contrast sensitivity (CS) were assessed. Objective VI was defined as having VI in distance VA (worse than 20/40), near VA (worse than 20/40), or CS (worse than 1.55 logCS). Receiver operating characteristic analysis was used to compare performance of VD in predicting VI. To investigate factors that influence discordance, we limited our sample to adults with VI and used a multivariable logistic regression model to identify factors associated with not reporting VD. Similar analyses were performed to explore factors associated with reporting VD in adults without VI. MAIN OUTCOME MEASURES: Discordance factors. RESULTS: Four thousand nine hundred ninety-nine adults were included in the 2022 cohort. Visual difficulty achieved an area under the curve (AUC) of 56.0 (95% confidence interval [CI], 55.2-56.9) in predicting VI, with a sensitivity of 15.8 (95% CI, 14.2-17.5) and specificity of 96.3 (95% CI, 95.5-96.9). Characteristics associated with not reporting VD in adults with VI included female gender (odds ratio [OR], 0.64 [95% CI, 0.42-0.99]), Hispanic ethnicity (OR, 0.49 [95% CI, 0.31-0.78), higher income (≥75 000, OR, 1.99 [95% CI, 1.14-3.45]), ≥4 comorbidities (OR, 0.46 [95% CI, 0.29-0.72]), and depressive symptoms (OR, 0.49 [95% CI, 0.25-0.93]). Factors associated with self-reporting VD in the absence of VI included Hispanic ethnicity (OR, 2.11 [95% CI, 1.15-3.86]), higher income (≥$75 000, OR, 0.27 [95% CI, 0.12-0.63]), and anxiety symptoms (OR, 3.05 [95% CI, 1.56-5.97]). CONCLUSIONS: Self-reported VD is a distinct measure assessing disability and has limited ability in predicting objective VI. Caution is advised when using self-reported VD as a surrogate measure for objective VI in epidemiological studies, although it may still be an effective way to capture risk of current or future disability. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

4.
J Exp Biol ; 227(3)2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099472

RESUMO

Vision is an important sensory modality in birds, which can outperform other vertebrates in some visual abilities. However, sensitivity to achromatic contrasts - the ability to discern luminance difference between two objects or an object and its background - has been shown to be lower in birds compared with other vertebrates. We conducted a comparative study to evaluate the achromatic contrast sensitivity of 32 bird species from 12 orders using the optocollic reflex technique. We then performed an analysis to test for potential variability in contrast sensitivity depending on the corneal diameter to the axial length ratio, a proxy of the retinal image brightness. To account for potential influences of evolutionary relatedness, we included phylogeny in our analyses. We found a low achromatic contrast sensitivity for all avian species studied compared with other vertebrates (except small mammals), with high variability between species. This variability is partly related to phylogeny but appears to be independent of image brightness.


Assuntos
Visão de Cores , Sensibilidades de Contraste , Animais , Filogenia , Aves , Vertebrados , Mamíferos
5.
Artigo em Inglês | MEDLINE | ID: mdl-38805071

RESUMO

The electroretinogram (ERG), a non-invasive electrophysiological tool used in ophthalmology, is increasingly applied to investigate neural correlates of depression. The present study aimed to reconsider previous findings in major depressive disorder (MDD) reporting (1) a diminished contrast sensitivity and (2) a reduced patten ERG (PERG) amplitude ratio, and additionally, to assess (3) the photopic negative response (PhNR) from the flash ERG (fERG), with the RETeval® device, a more practical option for clinical routine use. We examined 30 patients with a MDD and 42 healthy controls (HC), assessing individual contrast sensitivity thresholds with an optotype-based contrast test. Moreover, we compared the PERG ratio, an established method for early glaucoma detection, between both groups. The handheld ERG device was used to measure amplitudes and peak times of the fERG components including a-wave, b-wave and PhNR in both MDD patients and HCs. MDD patients exhibited diminished contrast sensitivity together with a reduced PERG ratio, compared to HC. With the handheld ERG device, we found reduced a-wave amplitudes in MDD, whereas no significant differences were observed in the fERG b-wave or PhNR between patients and controls. The reduced contrast sensitivity and PERG ratio in MDD patients supports the hypothesis that depression is associated with altered visual processing. The findings underscore the PERG's potential as a possible objective marker for depression. The reduced a-wave amplitude recorded with the RETeval® system in MDD patients might open new avenues for using handheld ERG devices as simplified approaches for advancing depression research compared to the PERG.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38856953

RESUMO

AIMS: Impaired vision is an additional risk factor in elderly for falls. We investigated the hypothesis that treadmill (TM) walking affects visual function in both healthy elderly and those with early-moderate visual dysfunction due to glaucoma. METHODS: Thirty healthy controls (HC) aged 64-83 years and 18 glaucoma patients (GLA) aged 62-82 years participated in this cross-sectional study. The impact of TM-walking on visual function was assessed binocularly for (i) best-corrected visual acuity (BCVA) with and without crowding effect, (ii) contrast sensitivity (CS), and (iii) and visual field (mean deviation, VF-MD). Visual function was tested while participants were standing or during TM-walking for 2 speed conditions: (i) fast walking at their preferred speed and (ii) walking at a fixed speed of 3.5 km/h. RESULTS: GLA, most with early-moderate VF loss, performed equally well as HC. Independent of GROUP, an impact of SPEED on visual functions was statistically evident with large statistical effect size for (i) both types of BCVA with a mean loss of 0.02-0.05 logMAR (η2 = 0.41) and (ii) VF-MD with mean loss of 1 dB (η2 = 0.70), but not for CS. CONCLUSIONS: Here, we introduce a paradigm for the assessment of visual function during walking. We provide proof-of-concept that our approach allows for the identification of walking induced visual function loss, i.e., a deterioration of BCVA and VF-sensitivity during TM-walking in both groups. It is therefore of promise for the investigation of the relation of vision impairment and mobility, ultimately the increased frequency of falls in advanced glaucoma.

7.
BMC Ophthalmol ; 24(1): 86, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409015

RESUMO

BACKGROUND: To evaluate visual performance after implantation of the TFNT (Acrysof Panoptix, Alcon, Fort Worth, Texas, USA) and CNWT (Clareon Panoptix, Alcon, Fort Worth, Texas, USA) intraocular lens (IOL), and compare the lens shape observed by scanning electron microscope (SEM). METHODS: Eighteen patients (18 eyes) received implantation of the CNWT and Twenty patients (20 eyes) received implantation of the TFNT. Exclusion criteria were previous ocular surgeries, ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 1 months including manifest refraction; evaluation of refractive error, distance-corrected visual acuity (DCVA) at 5 m, 1 m, 70 cm, 50 cm, 40 cm, and 30 cm, slit-lamp examination; defocus curve testing; contrast sensitivity (CS) was performed. The lens shape of the TFNT and the CNWT was examined under SEM. RESULTS: Mean spherical equivalent was 0.11 ± 0.41 D (CNWT group) and 0.12 ± 0.34 D (TFNT group) 1 month postoperation. DCVA and defocus curve showed no significant difference between the two groups. CS was significantly higher in CNWT group than TFNT group at spatial frequencies of 6 cycles per degree (cpd). Observation of the IOL with a scanning electron microscope (SEM) revealed that CNWT group had improved diffraction structure and edge processing accuracy compared to TFNT group. CONCLUSION: There was no significant difference between the two groups in the defocus curve and visual acuity at all distances. CS was better in the CNWT group than in the TFNT group. IOL surface features may affect CS.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Microscopia Eletrônica de Varredura , Implante de Lente Intraocular , Pseudofacia/cirurgia , Visão Binocular , Refração Ocular , Desenho de Prótese
8.
Ophthalmic Physiol Opt ; 44(1): 5-16, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37728235

RESUMO

PURPOSE: To investigate the feasibility of children measuring their own contrast sensitivity using a range of tablet- and paper-based tests. METHODS: Forty children aged 5-15 years with amblyopia (N = 10), bilateral vision impairment (N = 10) or good vision (N = 20) measured their own vision on a screen-based optotype test (Manifold), a gamified vision test (PopCSF) and a paper-based test (Spotchecks) in a laboratory with minimal supervision. Completion rate, test-retest repeatability, test duration and participants' preferences were recorded for each test. RESULTS: Most participants (36/40) were able to perform all three tests. All tests were correlated with clinically measured visual acuity and contrast sensitivity (p < 0.001). The 95% coefficient of repeatability was 0.30 dB for Manifold, 0.29 dB for PopCSF and 0.13 dB for Spotchecks. All tests differentiated between children with reduced contrast sensitivity and control participants. PopCSF and Spotchecks were also able to differentiate between children with amblyopia and those with good vision. Median test time was 152, 130 and 202 s for Manifold, PopCSF and Spotchecks, respectively. Twenty-two participants preferred the PopCSF test, 10 preferred Spotchecks and 6 preferred Manifold. Thirty-nine out of the 40 children (98%) said they would measure their own vision at home using at least one of these tests every month. CONCLUSIONS: Children and young people can test their own contrast sensitivity with repeatable results. Of these three tests, the most repeatable was Spotchecks, the quickest was PopCSF and participants' favourite was PopCSF. Nearly all of the participants said they would be willing to use at least one of the three tests at home.


Assuntos
Ambliopia , Criança , Humanos , Adolescente , Ambliopia/diagnóstico , Sensibilidades de Contraste , Testes Visuais , Visão Ocular , Acuidade Visual
9.
Ophthalmic Physiol Opt ; 44(5): 1010-1016, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38699881

RESUMO

PURPOSE: Spectacle lenses with peripheral lenslets have shown promise for myopia control by providing peripheral myopic defocus signals. Here, we aimed to investigate the impact of prolonged exposure (>6 months) to peripheral myopic defocus on visual information processing in myopic children. METHODS: The study included 30 myopic children who habitually wore spectacle lenses with highly aspherical lenslets (HAL group) and 34 children who habitually wore single-vision (SV group) spectacles. The quick contrast sensitivity function (qCSF) was used to measure contrast sensitivity (CS) under conditions of no or high noise. Both groups were tested with HAL and SV lenses. The perceptual template model was utilised to fit the contrast sensitivity function (CSF) and determine differences in information processing efficiency through internal additive noise ( N add ) and perceptual template gain (ß). RESULTS: The areas under the log CSF in the SV group were significantly higher than for the HAL group in both zero-noise conditions with the SV test lens (p = 0.03) and high-noise conditions with the HAL test lens (p = 0.02). For 2 cycle per degree (cpd) stimuli, ß was significantly higher in the SV group with the HAL test lens than in the HAL group (p = 0.02), while there was a trend towards a significant difference in ß for 6 cpd stimuli (p = 0.07). However, there were no significant differences in N add between the two groups, with or without noise interference. CONCLUSION: The reduced CS observed in myopic children wearing HAL lenses for 6 months or more may be due to decreased ß. This suggests that prolonged use of spectacle lenses with peripheral myopic defocus signals may compromise the central visual system's ability to process additional external noise, resulting in decreased efficiency in visual information processing.


Assuntos
Sensibilidades de Contraste , Óculos , Miopia , Humanos , Miopia/fisiopatologia , Miopia/terapia , Criança , Feminino , Masculino , Sensibilidades de Contraste/fisiologia , Adolescente , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Percepção Visual/fisiologia
10.
Ophthalmic Physiol Opt ; 44(6): 1072-1083, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39031645

RESUMO

PURPOSE: SpotChecks is a new contrast sensitivity (CS) test designed for self-monitoring of vision. This study assessed the test-retest repeatability of take-home SpotChecks, in-office SpotChecks and near Pelli-Robson charts in healthy adults. METHODS: One eye of 61 healthy adults with near visual acuity (VA) of 6/9 or better (age range 22-84, mean 49 [18] years) was tested during two office visits (mean 10 [8] days apart). Each visit included high-contrast VA, then 12 randomly ordered CS tests (6 different SpotChecks and 6 different Pelli-Robson) under the same lighting (luminance 110 cd/m2), all at near in the same eye with habitual correction. The same eye was self-tested with take-home SpotChecks once a day on 6 days between the office visits. SpotChecks was scored by the logCS at the highest line with ≥2 errors. Pelli-Robson was scored by [0.05 × number of letters read correctly - 0.15]. Repeatability of logCS was defined as 1.96 2 Sw, Sw representing within-subject standard deviation. Comparison for repeatability was performed with Bootstrap hypothesis test. RESULTS: SpotChecks and Pelli-Robson showed similar intra-session or inter-visit repeatability (p = 0.14-0.81). Inter-day repeatability for take-home SpotChecks was 0.18 logCS, the same as that from the first measurements of two office visits with SpotChecks or Pelli-Robson. Inter-visit repeatability improved to 0.15 by using the average of two repeated measurements for SpotChecks (p = 0.02) or three repeated measurements for Pelli-Robson (p = 0.04). Age showed a small effect on logCS (-0.015/decade, p = 0.02) for both SpotChecks and Pelli-Robson. Mean logCS was 0.05 lower in those ≥50 years (SpotChecks 1.84 [0.10] and Pelli-Robson 1.77 [0.10]) compared with those <50 years of age (SpotChecks 1.89 [0.07] and Pelli-Robson 1.83 [0.07]). CONCLUSIONS: SpotChecks showed good repeatability with take-home and in-office testing in healthy adults, making it a promising tool for monitoring disease progression at home.


Assuntos
Sensibilidades de Contraste , Testes Visuais , Acuidade Visual , Humanos , Sensibilidades de Contraste/fisiologia , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Testes Visuais/métodos , Testes Visuais/instrumentação , Adulto Jovem , Reprodutibilidade dos Testes , Idoso , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Voluntários Saudáveis
11.
Ophthalmic Physiol Opt ; 44(1): 78-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37888774

RESUMO

Presbyopia is a visual condition that affects all of us, evolving with time, reducing the range of accommodation and the ability to work at near. Reading glasses, bifocals or multifocal lenses are the most common solutions. In this work, we demonstrate the near visual performance of new elastomeric auto-adherent lenses developed for the correction of presbyopia. Visual acuity and contrast sensitivity were measured in 10 presbyopic subjects. The results showed that wearing either conventional trial ophthalmic lenses or the new elastomeric lenses provided similar visual quality. These elastomeric lenses can be placed in, or removed from the distance-vision spectacles of the wearers, providing an affordable solution for correcting presbyopia at its clinical onset, which might be especially useful in subjects with different refractive error in each eye and for those with astigmatism.


Assuntos
Saúde da População , Presbiopia , Humanos , Presbiopia/terapia , Acuidade Visual , Visão Ocular , Sensibilidades de Contraste
12.
Ergonomics ; : 1-9, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38686974

RESUMO

The influence of various polarised glasses on visual performance is crucial due to their widespread. This study measured the visual contrast sensitivity (CS) of dominant eyes by quick contrast sensitivity function (qCSF) procedure at 10 spatial frequencies and 3 noise levels under nonglare, steady glare, steady glare with night lenses, and steady glare with day&night lenses, respectively. Later, the second experiment measured the subjects' subjective feelings under these four viewing conditions. The results showed that there was no significant difference in the CS between the two conditions with polarised glasses and the steady glare. However, the subjects reported greater comfort with glasses than without them. These results suggest that there was an underlying bias when people rated the polarised glasses, and the qCSF procedure was a useful tool for evaluating visual performance.


Whether polarised glasses can relieve the impairment of steady glare on contrast sensitivity over multi-spatial frequency and external noise levels is unaddressed. Using the quick CSF method, we revealed that CS declines with steady glare but polarised lenses don't significantly relieve it. However, subjects reported increased comfort, suggesting a perceptual bias.

13.
Int Ophthalmol ; 44(1): 76, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351422

RESUMO

PURPOSE: The aim was to investigate the changes in optic nerve function that may help in the diagnosis of subclinical optic nerve involvement in patients with Behçet's disease (BD) and isolated optic disc (OD) hyperfluorescence in fluorescein angiography (FA). MATERIALS AND METHODS: Three groups were formed; BD patients with isolated OD hyperfluorescence in FA, BD patients without ocular involvement (normal FA) and control group. A total of 88 eyes of 45 patients were included. The groups were compared in terms of OCT-RNFL, contrast sensitivity and VEP latency. RESULTS: When the OCT-RNFL values were compared, there was a significant difference between the control group and Behçet's patients with normal FA. Contrast sensitivity values differed significantly among the groups, and the lowest mean contrast sensitivity was observed in the group with OD hyperfluorescence (p < 0.05). CONCLUSION: As far as we know, this is the first publication that investigates optic nerve function in BD patients with isolated OD hyperfluorescence in FA. Assessment with FA of asymptomatic BD patients with visual complaints and low contrast sensitivity may be helpful at early detection of inflammatory optic neuropathy by close follow-up in patients with OD hyperfluorescence.


Assuntos
Síndrome de Behçet , Disco Óptico , Doenças do Nervo Óptico , Humanos , Síndrome de Behçet/complicações , Síndrome de Behçet/diagnóstico , Angiofluoresceinografia , Nervo Óptico/diagnóstico por imagem
14.
Int Ophthalmol ; 44(1): 276, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916772

RESUMO

PURPOSE: To evaluate mesopic and photopic contrast sensitivity in patients with congenital red-green color vision deficiency regarding with and without glare conditions and to compare these findings with age- and gender-matched healthy controls with normal color vision. METHODS: Patients with congenital red-green color vision deficiency and age- and gender-matched healthy controls were included in this cross-sectional comparative study. Contrast sensitivity measurements were taken from all subjects in 4 different conditions; binocular mesopic-without glare, mesopic-with glare, photopic-without glare, photopic-with glare, and the results were compared. RESULTS: Twenty one patients with color vision deficiency (13 deuteranopic, 8 protanopic) and 22 age- and gender-matched healthy controls were included in the study. The mean age was 35.2 ± 13.5 years in the protan group, 30.6 ± 7.7 years in the deutan group, 32.0 ± 8.8 years in the control group, and there was no significant difference in age between the groups (P > 0.05). The mean mesopic and photopic contrast sensitivity values of the groups at all spatial frequencies (1.5, 3, 6, 12, 18 cpd) were not statistically significant when evaluated by the multifactor repeated measures test of ANOVA to evaluate the effect of light conditions (with and without glare) (P > .05). CONCLUSION: Mesopic and photopic contrast sensitivity values of patients with congenital red-green color vision deficiency were similar to healthy controls regarding with and without glare conditions.


Assuntos
Defeitos da Visão Cromática , Visão de Cores , Sensibilidades de Contraste , Humanos , Sensibilidades de Contraste/fisiologia , Defeitos da Visão Cromática/fisiopatologia , Defeitos da Visão Cromática/diagnóstico , Feminino , Masculino , Estudos Transversais , Adulto , Visão de Cores/fisiologia , Adulto Jovem , Pessoa de Meia-Idade , Visão Mesópica/fisiologia , Ofuscação , Acuidade Visual , Adolescente
15.
Int Ophthalmol ; 44(1): 47, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38337138

RESUMO

PURPOSE: Myopia is controlled optically with peripheral defocus spectacles, multifocal contact lenses, or orthokeratology lenses. However, it is unknown which optical correction will improve visual performance. This scoping review aimed to identify and summarize studies on various visual functions using optical corrections for myopia control. METHODS: To develop the search strategy, population (Myopia), concept (visual performance), and context (unrestricted race/region) were used. PubMed, SCOPUS, Cochrane Library, and Web of Science databases were searched using the keywords myopia, contrast sensitivity, high and low contrast visual acuity, stereopsis, and optical correction of myopia control. This scoping review protocol was registered in the Open Science Framework registry and followed the framework for scoping review outlined by the Joanna Briggs Institute. RESULTS: Eight studies (n = 8) met the inclusion criteria and were included in the review. Four were conducted in Europe, two were conducted in China, and one was conducted in Japan and Singapore. Five studies were randomized controlled trials, out of which three used contact lenses and two studies used peripheral defocus spectacles lenses. Studies ranged from one day to 2 years. Three studies that used orthokeratology lenses were prospective study designs. Among the studies that used orthokeratology lenses and contact lenses, two studies measured the contrast sensitivity function with CSV1000 (Vector Vision) under mesopic and photopic conditions, with and without glare. Two studies measured the central and peripheral contrast sensitivity using psychophysics experiments. High and low contrast visual acuity was measured using the Freiburg Vision Test (n = 1) and ETDRS charts (n = 3), and stereopsis was assessed using a random dot stereogram (n = 1). The studies showed a reduction in central and peripheral contrast sensitivity function and low contrast acuity when treated with multifocal contact lenses, orthokeratology lenses, and peripheral defocus lenses compared with single-vision lenses. CONCLUSION: This scoping review found a reduction in central and peripheral contrast sensitivity function, as well as low contrast visual acuity when using various optical corrections for myopia control, while high-contrast visual acuity remained the same. The impact of visual functions may not influence the effectiveness of myopia control. Eye care practitioners should provide awareness to the parent and patient population about the potential visual impact of recent designs for optical corrections of myopia control.


Assuntos
Lentes de Contato , Óculos , Miopia , Procedimentos Ortoceratológicos , Acuidade Visual , Humanos , Miopia/fisiopatologia , Miopia/terapia , Acuidade Visual/fisiologia , Procedimentos Ortoceratológicos/métodos , Sensibilidades de Contraste/fisiologia , Refração Ocular/fisiologia
16.
Vestn Oftalmol ; 140(3): 70-74, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38962981

RESUMO

PURPOSE: This study evaluates the effectiveness of implantation of extended depth of focus (EDOF) intraocular lenses (IOL) in patients with cataract and glaucoma. MATERIAL AND METHODS: The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3-6 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points. RESULTS: On the first day after surgery, UCVA was 0.53±0.65, BCVA was 0.85±0.45. Near UCVA (at 40 cm) was 0.5±0.14 on the first day after surgery and 0.56±0.18 at 3-6 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (-3.1±2.9 dB). SCS values increased for objects of all sizes compared to preoperative values. CONCLUSION: Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.


Assuntos
Glaucoma , Implante de Lente Intraocular , Lentes Intraoculares , Acuidade Visual , Humanos , Feminino , Masculino , Idoso , Implante de Lente Intraocular/métodos , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Pessoa de Meia-Idade , Facoemulsificação/métodos , Resultado do Tratamento , Pressão Intraocular/fisiologia , Catarata/complicações , Catarata/fisiopatologia , Sensibilidades de Contraste/fisiologia , Desenho de Prótese
17.
Br Ir Orthopt J ; 20(1): 48-56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38250170

RESUMO

Introduction: The importance of the use of contrast sensitivity (CS) tests in orthoptic practice is well established. However, despite the clinical relevance the implementation within clinical care is known to be variable. There are no known studies that investigate the use of CS tests in Orthoptic clinics in the UK, therefore the aim of this study is to gather information from Orthoptists in the UK on their opinion of CS and use of CS testing in clinical practice, now and in the future. Methods: An online survey was distributed via JISC to the British and Irish Orthoptic Journal newsletter three times over a period of four weeks in June 2021 inviting practising orthoptists in the United Kingdom to complete. The questionnaire comprised of a series of questions regarding current use with free text responses for additional information. Results: There were 84 responses to the survey. The preferred test for adult and children testing is Pelli Robson with 50% reporting use of this test. 56% felt there is a need for a new CS test for young children, 12% said no and 32% were unsure. The highest percentage (57.1%) of participants were confident to some degree that their preferred test gave them useful clinical information. Conclusion: The result of the survey demonstrates the variability of CS testing currently in orthoptic practice in the UK. It also highlights the lack of currently available tests for children for CS testing, which may be addressed by the addition of the new Double Happy CS test.

18.
Saudi J Ophthalmol ; 38(1): 83-88, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628417

RESUMO

PURPOSE: To evaluate and contrast the contrast sensitivity defects present in strabismic and anisometropic amblyopes. And to find out the association of contrast deterioration with the visual acuity of the amblyopic eye, the magnitude of strabismus, and the amount of anisometropia in both groups. METHODS: This cross-sectional study was carried out in the orthoptics unit of a tertiary eye care facility between October 2021 and December 2021. There were 45 patients altogether. In the first phase, the patient's history and ocular examination data were recorded after informed consent. The Pelli-Robson chart was used to measure contrast sensitivity. In the second phase, results were interpreted using the SPSS (Statistical Package for the Social Sciences) version 26.0. RESULTS: Strabismic amblyopes were 24 and anisometropic amblyopes were 21. A significant positive association existed between both groups' contrast sensitivity and visual acuity (P = 0.000). A moderately negative correlation between contrast and anisometropia was statistically significant (P = 0.025) in anisometropic amblyopes. However, no association (P > 0.050) existed between the contrast and magnitude of strabismus in any group. CONCLUSION: The study concluded that contrast sensitivity decreases in both groups, whereas anisometropic amblyopes have poorer contrast than strabismic amblyopes. Excessively decreased contrast sensitivity among anisometropic amblyopes was solely because of the worst amblyopia in this group, whereas the magnitude of strabismus does not affect contrast sensitivity.

19.
Aging Brain ; 6: 100122, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39148934

RESUMO

Older adults with impairment in contrast sensitivity (CS), the ability to visually perceive differences in light and dark, are more likely to demonstrate limitations in mobility function, but the mechanisms underlying this relationship are poorly understood. We sought to determine if functional brain networks important to visual processing and mobility may help elucidate possible neural correlates of this relationship. This cross-sectional analysis utilized functional MRI both at rest and during a motor imagery (MI) task in 192 community-dwelling, cognitively-unimpaired older adults ≥ 70 years of age from the Brain Networks and Mobility study (B-NET). Brain networks were partitioned into network communities, groups of regions that are more interconnected with each other than the rest of the brain, the spatial consistency of the communities for multiple brain subnetworks was assessed. Lower baseline binocular CS was significantly associated with degraded sensorimotor network (SMN) community structure at rest. During the MI task, lower binocular CS was significantly associated with degraded community structure in both the visual (VN) and default mode network (DMN). These findings may suggest shared neural pathways for visual and mobility dysfunction that could be targeted in future studies.

20.
Front Integr Neurosci ; 18: 1367593, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560577

RESUMO

[This corrects the article DOI: 10.3389/fnint.2023.1234471.].

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA