1.
Sensors (Basel) ; 21(16)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34451003

RESUMO

The mechanical properties of biological cells, especially the elastic modulus and viscosity of cells, have been identified to reflect cell viability and cell states. The existing measuring techniques need additional equipment or operation condition. This paper presents a cell's viscoelasticity measurement method based on the spheroidization process of non-spherical shaped cell. The viscoelasticity of porcine fetal fibroblast was measured. Firstly, we introduced the process of recording the spheroidization process of porcine fetal fibroblast. Secondly, we built the viscoelastic model for simulating a cell's spheroidization process. Then, we simulated the spheroidization process of porcine fetal fibroblast and got the simulated spheroidization process. By identifying the parameters in the viscoelastic model, we got the elasticity (500 Pa) and viscosity (10 Pa·s) of porcine fetal fibroblast. The results showed that the magnitude of the elasticity and viscosity were in agreement with those measured by traditional method. To verify the accuracy of the proposed method, we imitated the spheroidization process with silicone oil, a kind of viscous and uniform liquid with determined viscosity. We did the silicone oil's spheroidization experiment and simulated this process. The simulation results also fitted the experimental results well.


Assuntos
Técnicas de Imagem por Elasticidade , Animais , Simulação por Computador , Módulo de Elasticidade , Elasticidade , Suínos , Viscosidade
2.
J Biomech ; 169: 112154, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38768541

RESUMO

Estimating the elasticity of hydrogel phantoms in a cell culture plane is important for understanding the cell behavior in response to various types of mechanical stimuli. Hence, a noncontact tool for measuring the elastic properties of hydrogel phantoms in such three-dimensional cell cultures is required. A well-known method to determine the mechanical properties of hydrogels is the transient wave method. However, due to the multiple reflections of waves from the boundaries, a bigger cell culture plane or multiple directional filters may be required. In this study, we utilized reverberant shear wave elastography, which is based on the autocorrelation principle, to evaluate the shear wave speed in hydrogel samples within a culture dish. Numerical simulations were performed first to confirm the validity of the reverberant elastography method. Subsequently, we used this method to measure the wave speeds in hydrogel phantoms with different concentrations. Shear rheology tests were also performed, and their results were found to be in good agreement with the measured shear wave speeds. The proposed method could be useful for measuring the elasticity of tissues in tissue engineering applications in an inexpensive and noncontact manner.


Assuntos
Técnicas de Imagem por Elasticidade , Hidrogéis , Imagens de Fantasmas , Hidrogéis/química , Técnicas de Imagem por Elasticidade/métodos , Elasticidade , Reologia/métodos
3.
Adv Wound Care (New Rochelle) ; 11(6): 297-310, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34470542

RESUMO

Objective: Skin fibrosis places an enormous burden on patients and society, but disagreement exists over methods to quantify severity of skin scarring. A suction cutometer measures skin elasticity in vivo, but it has not been widely adopted because of inconsistency in data produced. We investigated variability of several dimensionless parameters generated by the cutometer to improve their precision and accuracy. Approach: Twenty adult human subjects underwent suction cutometer measurement of normal skin (NS) and fibrotic scars (FS). Using Mode 1, each subject underwent five trials with each trial containing four curves. R0/2/5/6/7 and Q1/2/3 data were collected. Analyses were performed on these calculated parameters. Results: R0/2/5/6/7 and Q1/2 parameters from curves 1 to 4 demonstrated significant differences, whereas these same parameters were not significantly different when only using curves 2-4. Individual analysis of all parameters between curve 1 and every subsequent curve was statistically significant for R0, R2, R5, R6, R7, Q1, and Q2. No differences were appreciated for parameter Q3. Comparison between NS and FS were significantly different for parameters R5, Q1, and Q3. Innovation: Our study is the first demonstration of accurate comparison between NS and FS using the dimensionless parameters of a suction cutometer. Conclusions: Measured parameters from the first curve of each trial were significantly different from subsequent curves for both NS and FS. Precision and reproducibility of data from dimensionless parameters can therefore be improved by removing the first curve. R5, Q1, and Q3 parameters differentiated NS as more elastic than FS.


Assuntos
Envelhecimento da Pele , Pele , Adulto , Elasticidade , Humanos , Reprodutibilidade dos Testes , Fenômenos Fisiológicos da Pele
4.
Patient Saf Surg ; 9(1): 4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25621009

RESUMO

BACKGROUND: Decision-making in treatment of an acute compartment syndrome is based on clinical assessment, supported by invasive monitoring. Thus, evolving compartment syndrome may require repeated pressure measurements. In suspected cases of potential compartment syndromes clinical assessment alone seems to be unreliable. The objective of this study was to investigate the feasibility of a non-invasive application estimating whole compartmental elasticity by ultrasound, which may improve accuracy of diagnostics. METHODS: In an in vitro model, using an artificial container simulating dimensions of the human anterior tibial compartment, intra-compartmental pressures (p) were raised subsequently up to 80 mmHg by infusion of saline solution. The compartmental depth (mm) in the cross-section view was measured before and after manual probe compression (100 mmHg) upon the surface resulting in a linear compartmental displacement (∆d). This was repeated at rising compartmental pressures. The resulting displacements were related to the corresponding intra-compartmental pressures simulated in our model. A hypothesized relationship between pressures related compartmental displacement and the elasticity at elevated compartment pressures was investigated. RESULTS: With rising compartmental pressures, a non-linear, reciprocal proportional relation between the displacement (mm) and the intra-compartmental pressure (mmHg) occurred. The Pearson coefficient showed a high correlation (r(2) = -0.960). The intra-observer reliability value kappa resulted in a statistically high reliability (κ = 0.840). The inter-observer value indicated a fair reliability (κ = 0.640). CONCLUSIONS: Our model reveals that a strong correlation between compartmental strain displacements assessed by ultrasound and the intra-compartmental pressure changes occurs. Further studies are required to prove whether this assessment is transferable to human muscle tissue. Determining the complete compartmental elasticity by ultrasound enhancement, this application may improve detection of early signs of potential compartment syndrome.