Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 627
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Am J Obstet Gynecol ; 230(3): 295-307.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37673234

RESUMO

OBJECTIVE: This study aimed to quantify the association between mode of operative delivery in the second stage of labor (cesarean delivery vs operative vaginal delivery) and spontaneous preterm birth in a subsequent pregnancy. DATA SOURCES: MEDLINE, Embase, EmCare, CINAHL, the Cochrane Library, Web of Science: Core Collection, and Scopus were searched from database inception to April 1, 2023. STUDY ELIGIBILITY CRITERIA: All retrospective cohort studies with participants who had a second-stage cesarean delivery (defined as intrapartum cesarean delivery at full cervical dilation) or operative vaginal delivery (including forceps- and/or vacuum-assisted delivery) and that reported the rate of preterm birth (either spontaneous or not specified) in subsequent pregnancy were included. METHODS: Both a descriptive analysis and a meta-analysis were performed. A meta-analysis was performed for dichotomous data using the Mantel-Haenszel random-effects model and used the odds ratio as an effect measure with 95% confidence intervals. The risk of bias was assessed using Cochrane's 2022 Risk Of Bias In Non-randomized Studies of Exposure tool. RESULTS: After screening 2671 articles from 7 databases, a total of 18 retrospective cohort studies encompassing 605,138 patients were included. The pooled rates of spontaneous preterm birth in a subsequent pregnancy were 6.9% (12 studies) after second-stage cesarean delivery and 2.6% (8 studies) after operative vaginal delivery. A total of 7 studies encompassing 75,460 patients compared the primary outcome of spontaneous preterm birth after second-stage cesarean delivery vs operative vaginal delivery in an index pregnancy with an odds ratio of 2.01 (95% confidence interval, 1.57-2.58) in favor of operative vaginal delivery. However, most studies did not include important confounding factors, did not address exposure misclassification because of failed operative vaginal delivery, and considered operative vaginal delivery as a homogeneous category with no distinction between forceps- and vacuum-assisted deliveries. CONCLUSION: Although a synthesis of the existing literature suggests that the risk of spontaneous preterm birth is higher in those with a previous second-stage cesarean delivery than in those with operative vaginal delivery, the risk of bias in these studies is very high. Findings should be interpreted with caution.


Assuntos
Nascimento Prematuro , Gravidez , Feminino , Recém-Nascido , Humanos , Nascimento Prematuro/epidemiologia , Estudos Retrospectivos , Segunda Fase do Trabalho de Parto , Estudos de Coortes , Parto Obstétrico
2.
Am J Obstet Gynecol ; 230(3): 279-294.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38168908

RESUMO

Pelvic floor disorders after childbirth have distressing lifelong consequences for women, requiring more than 300,000 women to have surgery annually. This represents approximately 10% of the 3 million women who give birth vaginally each year. Vaginal birth is the largest modifiable risk factor for prolapse, the pelvic floor disorder most strongly associated with birth, and is an important contributor to stress incontinence. These disorders require 10 times as many operations as anal sphincter injuries. Imaging shows that injuries of the levator ani muscle, perineal body, and membrane occur in up to 19% of primiparous women. During birth, the levator muscle and birth canal tissues must stretch to more than 3 times their original length; it is this overstretching that is responsible for the muscle tear visible on imaging rather than compression or neuropathy. The injury is present in 55% of women with prolapse later in life, with an odds ratio of 7.3, compared with women with normal support. In addition, levator damage can affect other aspects of hiatal closure, such as the perineal body and membrane. These injuries are associated with an enlarged urogenital hiatus, now known as antedate prolapse, and with prolapse surgery failure. Risk factors for levator injury are multifactorial and include forceps delivery, occiput posterior birth, older maternal age, long second stage of labor, and birthweight of >4000 g. Delivery with a vacuum device is associated with reduced levator damage. Other steps that might logically reduce injuries include manual rotation from occiput posterior to occiput anterior, slow gradual delivery, perineal massage or compresses, and early induction of labor, but these require study to document protection. In addition, teaching women to avoid pushing against a contracted levator muscle would likely decrease injury risk by decreasing tension on the vulnerable muscle origin. Providing care for women who have experienced difficult deliveries can be enhanced with early recognition, physical therapy, and attention to recovery. It is only right that women be made aware of these risks during pregnancy. Educating women on the long-term pelvic floor sequelae of childbirth should be performed antenatally so that they can be empowered to make informed decisions about management decisions during labor.


Assuntos
Distúrbios do Assoalho Pélvico , Diafragma da Pelve , Gravidez , Feminino , Humanos , Diafragma da Pelve/lesões , Parto Obstétrico/efeitos adversos , Canal Anal/lesões , Distúrbios do Assoalho Pélvico/etiologia , Distúrbios do Assoalho Pélvico/prevenção & controle , Prolapso
3.
Am J Obstet Gynecol ; 230(3S): S917-S931, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38462263

RESUMO

Assisted vaginal birth rates are falling globally with rising cesarean delivery rates. Cesarean delivery is not without consequence, particularly when carried out in the second stage of labor. Cesarean delivery in the second stage is not entirely protective against pelvic floor morbidity and can lead to serious complications in a subsequent pregnancy. It should be acknowledged that the likelihood of morbidity for mother and baby associated with cesarean delivery increases with advancing labor and is greater than spontaneous vaginal birth, irrespective of the method of operative birth in the second stage of labor. In this article, we argue that assisted vaginal birth is a skilled and safe option that should always be considered and be available as an option for women who need assistance in the second stage of labor. Selecting the most appropriate mode of birth at full dilatation requires accurate clinical assessment, supported decision-making, and personalized care with consideration for the woman's preferences. Achieving vaginal birth with the primary instrument is more likely with forceps than with vacuum extraction (risk ratio, 0.58; 95% confidence interval, 0.39-0.88). Midcavity forceps are associated with a greater incidence of obstetric anal sphincter injury (odds ratio, 1.83; 95% confidence interval, 1.32-2.55) but no difference in neonatal Apgar score or umbilical artery pH. The risk for adverse outcomes is minimized when the procedure is conducted by a skilled accoucheur who selects the most appropriate instrument likely to achieve vaginal birth with the primary instrument. Anticipation of potential complications and dynamic decision-making are just as important as the technique for safe instrument use. Good communication with the woman and the birthing partner is vital and there are various recommendations on how to achieve this. There have been recent developments (such as OdonAssist) in device innovation, training, and strategies for implementation at a scale that can provide opportunities for both improved outcomes and reinvigoration of an essential skill that can save mothers' and babies' lives across the world.


Assuntos
Cesárea , Trabalho de Parto , Gravidez , Recém-Nascido , Feminino , Humanos , Cesárea/efeitos adversos , Vácuo-Extração , Canal Anal , Mães , Parto Obstétrico/efeitos adversos , Estudos Retrospectivos
4.
Am J Obstet Gynecol ; 230(3S): S932-S946.e3, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38462264

RESUMO

BACKGROUND: Decreasing rates of assisted vaginal birth have been paralleled with increasing rates of cesarean deliveries over the last 40 years. The OdonAssist is a novel device for assisted vaginal birth. Iterative changes to clinical parameters, device design, and technique have been made to improve device efficacy and usability. OBJECTIVE: This study aimed to determine if the feasibility, safety, and efficacy of the OdonAssist device were sufficient to justify conducting a future randomized controlled trial. STUDY DESIGN: An open-label nonrandomized study of 104 participants having a clinically indicated assisted vaginal birth using the OdonAssist was undertaken at Southmead Hospital, Bristol, United Kingdom. Data were also collected from participants who consented to participate in the study but for whom trained OdonAssist operators were not available, providing a nested cohort. The primary clinical outcome was the proportion of births successfully expedited with the OdonAssist. Secondary outcomes included clinical, patient-reported, operator-reported, device and health care utilization. Neonatal outcome data were reviewed at day 28, and maternal outcomes were investigated up to day 90. Given that the number of successful OdonAssist births was ≥61 out of 104, the hypothesis of a poor rate of 50% was rejected in favor of a good rate of ≥65%. RESULTS: Between August 2019 and June 2021, 941 (64%) of the 1471 approached, eligible participants consented to participate. Of these, 104 received the OdonAssist intervention. Birth was assisted in all cephalic vertex fetal positions, at all stations ≥1 cm below the ischial spines (with or without regional analgesia). The OdonAssist was effective in 69 of the 104 (66%) cases, consistent with the hypothesis of a good efficacy rate. There were no serious device-related maternal or neonatal adverse reactions, and there were no serious adverse device effects. Only 4% of neonatal soft tissue bruising in the successful OdonAssist group was considered device-related, as opposed to 20% and 23% in the unsuccessful OdonAssist group and the nested cohort, respectively. Participants reported high birth perception scores. All practitioners found the device use to be straightforward. CONCLUSION: Recruitment to an interventional study of a new device for assisted vaginal birth is feasible; 64% of eligible participants were willing to participate. The success rate of the OdonAssist was comparable to that of the Kiwi OmniCup when introduced in the same unit in 2002, meeting the threshold for a randomized controlled trial to compare the OdonAssist with current standard practice. There were no disadvantages of study participation in terms of maternal and neonatal outcomes. There were potential advantages of using the OdonAssist, particularly reduced neonatal soft tissue injury. The same application technique is used for all fetal positions, with all operators deeming the device straightforward to use. This study provides important data to inform future study design.


Assuntos
Cesárea , Cabeça , Feminino , Recém-Nascido , Gravidez , Humanos , Reino Unido , Vagina
5.
Am J Obstet Gynecol ; 230(3S): S653-S661, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38462251

RESUMO

Childbirth is a defining moment in anyone's life, and it occurs 140 million times per year. Largely a physiologic process, parturition does come with risks; one mother dies every two minutes. These deaths occur mostly among healthy women, and many are considered preventable. For each death, 20 to 30 mothers experience complications that compromise their short- and long-term health. The risk of birth extends to the newborn, and, in 2020, 2.4 million neonates died, 25% in the first day of life. Hence, intrapartum care is an important priority for society. The American Journal of Obstetrics & Gynecology has devoted two special Supplements in 2023 and 2024 to the clinical aspects of labor at term. This article describes the content of the Supplements and highlights new developments in the induction of labor (a comparison of methods, definition of failed induction, new pharmacologic agents), management of the second stage, the value of intrapartum sonography, new concepts on soft tissue dystocia, optimal care during the third stage, and common complications that account for maternal death, such as infection, hemorrhage, and uterine rupture. All articles are available to subscribers and non-subscribers and have supporting video content to enhance dissemination and improve intrapartum care. Our hope is that no mother suffers because of lack of information.


Assuntos
Trabalho de Parto , Ruptura Uterina , Gravidez , Recém-Nascido , Feminino , Humanos , Ruptura Uterina/etiologia , Parto Obstétrico , Trabalho de Parto Induzido/métodos , Parto
6.
BJOG ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39030798

RESUMO

OBJECTIVE: To determine the prevalence and secular trends of obstetric anal sphincter injuries (OASIS) in vacuum and forceps deliveries in Norway, both with and without episiotomy. DESIGN: Population-based real-world data collected during 2001-2018. SETTING: Medical Birth Registry Norway. POPULATION OR SAMPLE: Nulliparous women with singleton foetuses in a cephalic presentation delivered by either vacuum or forceps (n = 70 783). METHODS: Logistic regression analyses were applied to the OASIS prevalence in six 3-year time periods. Both crude odds ratios and adjusted odds ratios (aORs) with 95% confidence intervals (CIs) were determined. MAIN OUTCOME MEASURES: OASIS prevalence. RESULTS: The OASIS prevalence in vacuum and forceps deliveries decreased from 14.8% during 2001-2003 to 5.2% during 2016-2018. The overall reduction between the first and last 3-year time period was 61% (aOR = 0.39, 95% CIs = 0.35-0.43). The only exception to this decreasing trend in OASIS was found in forceps deliveries performed without an episiotomy. The OASIS prevalence was approximately twofold higher in forceps compared to vacuum deliveries (aOR = 1.92, 95% CIs = 1.79-2.05). Performing either a mediolateral or lateral episiotomy was associated with a 45% decrease in the prevalence of OASIS relative to no episiotomy (aOR = 0.55, 95% CIs = 0.52-0.58). CONCLUSIONS: Opting for vacuum rather than forceps delivery in conjunction with a mediolateral or lateral episiotomy could significantly lower the OASIS prevalence in nulliparous women.

7.
Brain Topogr ; 37(1): 63-74, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38062326

RESUMO

Cognitive reappraisal (CR) is a mechanism for emotion regulation, and the prefrontal cortex (PFC) plays a central role in the regulation of emotions. We tested the hypothesis of an association between CR function and microstructural properties of forceps minor (a commissural bundle within the PFC) in healthy subjects (HS). We analyzed a population of 65 young HS of a public dataset. The diffusion tensor imaging (DTI) sequence of every subject was analyzed to extract the derived shape (diameter and volume) and DTI metrics in terms of fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) of the forceps minor. The CR subscale of the German version of the Emotion Regulation Questionnaire (ERQ) was used for CR assessment. The Shapiro-Wilk test was applied to test the assumption of normality in all these parameters, adopting a statistical threshold at p < 0.05. Whenever appropriate a non-parametric two-tailed partial correlation analysis was applied to test for correlations between the CR ERQ score and the derived shape and DTI metrics, including age and sex as confounders, adopting a statistical threshold at p < 0.05. The non-parametric two-tailed partial correlation analysis revealed a mildly significant correlation with FA (ρ = 0.303; p = 0.016), a weakly significant negative correlation with MD (ρ = - 0.269; p = 0.033), and a mildly significant negative correlation with RD (ρ = - 0.305; p = 0.015). These findings suggest a correlation between DTI microstructural properties of forceps minor and CR.


Assuntos
Encéfalo , Imagem de Tensor de Difusão , Humanos , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética , Cognição , Instrumentos Cirúrgicos , Anisotropia
8.
Respirology ; 29(5): 396-404, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246887

RESUMO

BACKGROUND AND OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a diagnostic procedure with adequate performance; however, its ability to provide specimens of sufficient quality and quantity for treatment decision-making in advanced-stage lung cancer may be limited, primarily due to blood contamination. The use of a 0.96-mm miniforceps biopsy (MFB) permits true histological sampling, but the resulting small specimens are unsuitable for the intended applications. Therefore, we introduced a 1.9-mm standard-sized forceps biopsy (SFB) and compared its utility to that of MFB. METHODS: We prospectively enrolled patients from three institutions who presented with hilar/mediastinal lymphadenopathy and suspected advanced-stage lung cancer, or those who were already diagnosed but required additional tissue specimens for biomarker analysis. Each patient underwent MFB followed by SFB three or four times through the tract created by TBNA using a 22-gauge needle on the same lymph node (LN). Two pathologists assessed the quality and size of each specimen using a virtual slide system, and diagnostic performance was compared between the MFB and SFB groups. RESULTS: Among the 60 enrolled patients, 70.0% were diagnosed with adenocarcinoma. The most frequently targeted sites were the lower paratracheal LNs, followed by the interlobar LNs. The diagnostic yields of TBNA, MFB and SFB were 91.7%, 93.3% and 96.7%, respectively. The sampling rate of high-quality specimens was significantly higher in the SFB group. Moreover, the mean specimen size for SFB was three times larger than for MFB. CONCLUSION: SFB is useful for obtaining sufficient qualitative and quantitative specimens.


Assuntos
Neoplasias Pulmonares , Linfadenopatia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Prospectivos , Broncoscopia/métodos , Mediastino/patologia , Biópsia Guiada por Imagem , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Linfadenopatia/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Instrumentos Cirúrgicos , Estudos Retrospectivos
9.
BMC Pregnancy Childbirth ; 24(1): 253, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589802

RESUMO

BACKGROUND: The objective of this study was to identify and qualify, by means of a three-dimensional kinematic analysis, the postures and movements of obstetricians during a simulated forceps birth, and then to study the association of the obstetricians' experience with the technique adopted. METHOD: Fifty-seven volunteer obstetricians, 20 from the Limoges and 37 from the Poitiers University hospitals, were included in this multi-centric study. They were classified into 3 groups: beginners, intermediates, and experts, beginners having performed fewer than 10 forceps deliveries in real conditions, intermediates between 10 and 100, and experts more than 100. The posture and movements of the obstetricians were recorded between December 2020 and March 2021 using an optoelectronic motion capture system during simulated forceps births. Joint angles qualifying these postures and movements were analysed between the three phases of the foetal traction. These phases were defined by the passage of a virtual point associated with the forceps blade through two anatomical planes: the mid-pelvis and the pelvic outlet. Then, a consolidated ascending hierarchical classification (AHC) was applied to these data in order to objectify the existence of groups of similar behaviours. RESULTS: The AHC distinguished four different postures adopted when crossing the first plane and three different traction techniques. 48% of the beginners adopted one of the two raised posture, 22% being raised without trunk flexion and 26% raised with trunk flexion. Conversely, 58% of the experts positioned themselves in a "chevalier servant" posture (going down on one knee) and 25% in a "squatting" posture before initiating traction. The results also show that the joint movement amplitude tends to reduce with the level of expertise. CONCLUSION: Forceps delivery was performed in different ways, with the experienced obstetricians favouring postures that enabled observation at the level of the maternal perineum and techniques reducing movement amplitude. The first perspective of this work is to relate these different techniques to the traction force generated. The results of these studies have the potential to contribute to the training of obstetricians in forceps delivery, and to improve the safety of women and newborns.


Assuntos
Extração Obstétrica , Obstetra , Gravidez , Humanos , Feminino , Recém-Nascido , Extração Obstétrica/métodos , Parto Obstétrico , Forceps Obstétrico , Postura
10.
Artigo em Inglês | MEDLINE | ID: mdl-38951225

RESUMO

INTRODUCTION: Magnetic intraocular foreign bodies can be removed with magnetized disposable forceps. Aim of this study is to compare the forceps magnetizability of different size, form and manufacturer. METHODS: The forceps were magnetized using an established procedure. The inducible magnetic flux density was measured at the tip of the forceps. The mass that can be lifted with the magnetized forceps was then tested using steel balls in BSS solution. The weight of the metal parts of the forceps was measured. RESULTS: The magnetic flux density that could be induced, the weight of the steel balls that could be lifted and the mass of stainless steel used in the forceps were as follows: Alcon end-grasping 23G: 7.12 mT, 87.43 mg, 1191 mg; Alcon end-grasping 25G: 6.43 mT, 87.43 mg, 1189 mg; Alcon serrated: 4.39 mT, 63.78 mg, 1284 mg; Alcon serrated 23G: 3.62 mT, 13.74 mg, 1200 mg; Alcon serrated 25G: 2.4 mT, 13.74 mg, 1195 mg; DORC end-grasping 23G: 5.52 mT, 32.54 mg, 153 mg; Synergetics end-grasping 23G: 4.35 mT, 16.37 mg, 193 mg; Vitreq BV end-grasping 23G: 2.65 mT, none, 88 mg. DISCUSSION: The magnetizability of a disposable microforceps seems to depend on the mass of steel at the tip of the forceps. The structure of the iron lattice could have an even greater influence. Not every disposable forceps can be sufficiently magnetized for this technique.

11.
BMC Ophthalmol ; 24(1): 80, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383362

RESUMO

PURPOSE: To compare the efficacy and efficiency of self-assembled intraocular rare earth magnet and forceps in removing intraocular foreign bodies(IOFBs) undergoing 25-gauge(G) pars plana vitrectomy. METHODS: A total of 30 patients with metallic IOFB underwent 25-G PPV were enrolled into this study. Self-assembled intraocular rare earth magnet were used in 15 patients(bar group), and forceps were used in 15 patients(forceps group). Success rate of removing IOFB, time taken to remove IOFB, incidence of IOFB slippage and fall, iatrogenic retinal damages were compared between the two groups. RESULTS: There was no significant difference in success rate of removing IOFBs between the groups(93.3% and 100%, P > 0.99). The median time taken of removing FB was significantly shorter in bar group than in forceps group(112 and 295 s, P = 0.001). None of the patients in bar group had IOFB slippage and fall, or related iatrogenic retinal damage in the process of removal. In forceps group, IOFB slippage and fall during removal were observed in 7 of 15(47.6%) patients, related iatrogenic retinal injuries were recorded in 6 of 15(40.0%) patients, both were significantly higher than bar group(P = 0.003 and P = 0.017, respectively). CONCLUSIONS: Compared with forceps, the assembled intraocular magnet can greatly reduce the possibility of IOFB slippage and fall, prevent related iatrogenic retinal damage, and shorten the time taken to remove IOFB. The assembled intraocular magnet can be an useful tool in removing metallic IOFBs in PPV.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Doenças Retinianas , Humanos , Vitrectomia , Imãs , Estudos Retrospectivos , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Instrumentos Cirúrgicos , Doenças Retinianas/cirurgia , Doença Iatrogênica , Ferimentos Oculares Penetrantes/etiologia , Ferimentos Oculares Penetrantes/cirurgia
12.
Eur Spine J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750099

RESUMO

OBJECTIVE: To develop posterior reduction forceps for atlantoaxial dislocation and evaluate the preliminary clinical application of this forceps in assisting simple posterior screw-rod system reduction and fixation in the treatment of irreducible atlantoaxial dislocation. METHODS: Based on the posterior atlantoaxial screw-rod system, posterior reduction forceps was developed to assist simple posterior screw-rod system for the treatment of irreducible atlantoaxial dislocation. From January 2021 to October 2022, 10 cases with irreducible atlantoaxial dislocation were treated with this technique. The Japanese Orthopaedic Association (JOA) score was applied before and after surgery to evaluate the neurological status of the patient, and the Atlanto-dental interval (ADI) was measured before and after surgery to evaluate the atlantoaxial reduction. X-ray and CT were performed to evaluate internal fixation, atlantoaxial sequence and bone graft fusion during regular follow-up. MRI was performed to evaluate the status of atlantoaxial reduction and spinal cord compression after surgery. RESULTS: All 10 patients were successfully operated, and there were no complications such as spinal nerve and vascular injury. Postoperative clinical symptoms were significantly relieved in all patients, and postoperative JOA score and ADI were significantly improved compared with those before surgery (P < 0.05). CONCLUSIONS: The developed posterior reduction forceps for atlantoaxial dislocation can assist the simple posterior screw-rod system in the treatment of irreducible atlantoaxial dislocation to avoid the release in anterior or posterior approach and reduce the difficulty of surgery. The preliminary results of this technique are satisfactory and it has a good application prospect.

13.
J Obstet Gynaecol Can ; 46(5): 102415, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38387834

RESUMO

OBJECTIVES: To quantify variation in the association between episiotomy and obstetric anal sphincter injury (OASI) by maternity care provider in spontaneous and operative vaginal deliveries (SVDs and OVDs). METHODS: Population-based retrospective cohort study of vaginal, term deliveries among nullipara in Canada (2004-2015). Adjusted rate ratios (ARRs) and 95% CIs were estimated using log-binomial regression to quantify the associations between episiotomy and OASI, stratified by care provider (obstetrician [OB], family physician [FP], or registered midwife [RM]) while adjusting for potential confounders. RESULTS: The study included 631 642 deliveries. Episiotomy use varied by provider: among SVDs, the episiotomy rate was 19.6%, 14.4%, and 8.4% in the OB, FP, and RM groups, respectively. The rate of OASI was higher among SVDs with versus without episiotomy (5.8% vs 4.6%). Conversely, OASI occurred less frequently in operative vaginal deliveries with episiotomy (15.3%) compared with those without (16.7%). In all provider groups, the ARR for OASI was increased with episiotomy in SVD and decreased with episiotomy with forceps delivery. No differences in these associations were observed by provider except among vacuum delivery (ARR with episiotomy vs. without, OB: 0.88, 95% CI 0.84-0.92; FP: 0.89, 95% CI 0.83-0.96, RM: 1.22, 95% CI 1.02-1.48). CONCLUSIONS: In nullipara, irrespective of maternity care provider, there is a positive association between episiotomy and OASI among SVDs and an inverse association between episiotomy and deliveries with forceps. The relationship between episiotomy and OASI is modified by maternity care providers among vacuum deliveries.


Assuntos
Canal Anal , Episiotomia , Paridade , Humanos , Episiotomia/estatística & dados numéricos , Episiotomia/efeitos adversos , Feminino , Canal Anal/lesões , Gravidez , Estudos Retrospectivos , Adulto , Canadá/epidemiologia , Obstetrícia/estatística & dados numéricos , Complicações do Trabalho de Parto/epidemiologia , Adulto Jovem , Tocologia/estatística & dados numéricos , Médicos de Família/estatística & dados numéricos , Parto Obstétrico/efeitos adversos , Parto Obstétrico/estatística & dados numéricos
14.
Artigo em Inglês | MEDLINE | ID: mdl-38769797

RESUMO

OBJECTIVE: To explore the clinical feasibility of different treatment methods for persistent occipitotransverse position and the influence on maternal and infant complications. METHOD: During the trial of vaginal delivery from April 2020 to March 2023 in our hospital, the cervix was fully dilated and the presentation was located at +2 station. Ninety-six pregnant women with fetal presentation at +4 station, occipitotransverse fetal position, maternal complications, abnormalities in the second stage of labor, and or fetal distress were divided into two groups: 65 patients with Kielland forceps vaginal delivery and 31 patients underwent emergency cesarean section. The delivery time, vaginal laceration rate, postpartum blood loss volume, puerperal infection rate, neonatal birth injury rate, and neonatal 1 min Apgar scores were analyzed. RESULTS: The delivery outcomes and maternal and neonatal complications of 96 pregnant women were analyzed: the application of Kielland forceps delivery time was shorter, while the vaginal laceration rate, postpartum hemorrhage, puerperal infection rate were significantly lower than that of patients undergoing emergency cesarean section and the neonatal 1 min Apgar score was higher than that of emergency cesarean section group (p < 0.05). CONCLUSION: It was clinically appropriate to use Kielland forceps in vaginal delivery when the persistent occipitotransverse position was present and delivery needed to be expediated. Use of Kielland forceps can shorten the delivery time, improve the success rate of vaginal delivery and reduce the complications of mothers and infants.

15.
Sensors (Basel) ; 24(5)2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38475023

RESUMO

The drug efficacy evaluation of tumor-selective photosensitive substances was expected to be enabled by imaging the fluorescence intensity in the tumor area. However, fluorescence observation is difficult during treatments that are performed during gastrointestinal endoscopy because of the challenges associated with including the fluorescence filter in the camera part. To address this issue, this study developed a device that integrates a narrow camera and a laser diffuser to enable fluorescence imaging through a forceps port. This device was employed to demonstrate that a laser diffuser with an NIR fluorescence imaging sensor could be delivered through a 3.2 mm diameter port. In addition, fluorescence images of Cetuximab-IR700 were successfully observed in two mice, and the fluorescence intensity confirmed that the fluorescence decayed within 330 s. This device is expected to have practical application as a tool to identify the optimal irradiation dose for tumor-selective photosensitive substances under endoscopy.


Assuntos
Luz , Fototerapia , Camundongos , Animais , Linhagem Celular Tumoral , Fototerapia/métodos , Imagem Óptica/métodos , Endoscopia Gastrointestinal
16.
Acta Chir Belg ; : 1-9, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38696140

RESUMO

BACKGROUND: History has paid little attention to the childbirth of Marie Louise, second wife to the Emperor Napoleon I. Most historians state that the obstetrician Antoine Dubois needed to use his forceps during a difficult breech delivery. As practicing obstetricians we aimed to reconstruct the likely course of events using a forensic approach. METHODS: We have consulted historical documents and key witness accounts as primary sources. We have followed the clinical guidance of the 1807 edition of 'l'Art des Accouchemens'. We have tested a new hypothesis of the possible course of the childbirth through a simulation using the Assisted Vaginal Birth Module PROMPT Flex CDE® as an obstetrical model and an authentic Levret forceps. DISCUSSION: A transverse lie with hip presentation is the most plausible diagnosis of the foetal malposition that complicated the delivery of Marie Louise by Antoine Dubois. The long duration of the delivery of the entrapped foetal head and the insistence on the presence of his colleague Corvisart by Antoine Dubois can be explained through our hypothesis that the occiput of the entrapped foetal head was very likely in a transverse position. The seemingly impossible application of a forceps in this position, had already been described in the nineteenth century both in France and outside. CONCLUSION: Our simulation confirmed the practicability of the application of the forceps as assumed by our hypothesis. Definitive proof that this scenario actually happened, cannot be given because there are no written first-hand accounts by Dubois on the delivery.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38400835

RESUMO

BACKGROUND: Few studies have analyzed the effect of the size of the working space in training on the acquisition of endoscopic skills. In this study, adult- and infant-sized dry boxes (DBs) were used to verify how the size of the working space in training affects forceps manipulation and learning curve. MATERIAL AND METHODS: Seventy-two medical students were enrolled. The task was peg transfer. The training environment was divided into adult- and infant-sized DBs. Skill evaluations were also divided into adult- and infant-sized DBs (four groups in total). The forceps manipulation characteristics and task completion time were compared before and after training. RESULTS: Regarding skill evaluations using adult-sized DBs, there were no significant differences between the infant- and adult-sized DB-trained groups. Regarding skill evaluations using infant-sized DBs, there were no significant differences between the groups before training. After training, there was no significant difference in the total path length or average acceleration of the forceps between the groups. However, the infant-sized DB-trained group had a significantly faster average forceps velocity and faster task completion time than the adult-sized DB-trained group. CONCLUSION: Training with a small DB is more efficient in acquiring smoother and faster forceps manipulation in a small working space.

18.
Hum Brain Mapp ; 44(10): 4101-4119, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37195079

RESUMO

Unveiling the details of white matter (WM) maturation throughout ageing is a fundamental question for understanding the ageing brain. In an extensive comparison of brain age predictions and age-associations of WM features from different diffusion approaches, we analyzed UK Biobank diffusion magnetic resonance imaging (dMRI) data across midlife and older age (N = 35,749, 44.6-82.8 years of age). Conventional and advanced dMRI approaches were consistent in predicting brain age. WM-age associations indicate a steady microstructure degeneration with increasing age from midlife to older ages. Brain age was estimated best when combining diffusion approaches, showing different aspects of WM contributing to brain age. Fornix was found as the central region for brain age predictions across diffusion approaches in complement to forceps minor as another important region. These regions exhibited a general pattern of positive associations with age for intra axonal water fractions, axial, radial diffusivities, and negative relationships with age for mean diffusivities, fractional anisotropy, kurtosis. We encourage the application of multiple dMRI approaches for detailed insights into WM, and the further investigation of fornix and forceps as potential biomarkers of brain age and ageing.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Envelhecimento , Corpo Caloso
19.
Hum Brain Mapp ; 44(8): 3302-3310, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36971658

RESUMO

Approximately 2%-3% of the world population suffers from obsessive-compulsive disorder (OCD). Several brain regions have been involved in the pathophysiology of OCD, but brain volumes in OCD may vary depending on specific OCD symptom dimensions. The study aims to explore how white matter structure changes in particular OCD symptom dimensions. Prior studies attempt to find the correlation between Y-BOCS scores and OCD patients. However, in this study, we separated the contamination subgroup in OCD and compared directly to healthy control to find regions that exactly related to contamination symptoms. To evaluate structural alterations, diffusion tensor imaging was acquired from 30 OCD patients and 34 demographically matched healthy controls. Data were processed using tract-based spatial statistics (TBSS) analysis. First, by comparing all OCD to healthy controls, significant fractional anisotropy (FA) decreased in the right anterior thalamic radiation, right corticospinal tract, and forceps minor observed. Then by comparing the contamination subgroup to healthy control, FA decreases in the forceps minor region. Consequently, forceps minor plays a central role in the pathophysiology of contamination behaviors. Finally, other subgroups were compared to healthy control and discovered that FA in the right corticospinal tract and right anterior thalamic radiation is reduced.


Assuntos
Transtorno Obsessivo-Compulsivo , Substância Branca , Humanos , Imagem de Tensor de Difusão/métodos , Substância Branca/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Corpo Caloso , Transtorno Obsessivo-Compulsivo/diagnóstico por imagem , Anisotropia
20.
Ann Surg Oncol ; 30(9): 5923-5929, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37394667

RESUMO

BACKGROUND: Here we compare the difference in recent outcomes between the use of Maryland forceps (MF) and electrocoagulation hooks (EH) in robotic-assisted thoracoscopic radical lung cancer resection. PATIENTS AND METHODS: We retrospectively analyze the clinical data of 247 patients with lung cancer who underwent robotic-assisted thoracoscopic surgery from February 2018 to December 2022. On the basis of the intraoperative use of energy devices, we divided the clinical data into two groups, including 84 cases in the MF group and 163 cases in the EH group, respectively. The patients in the two groups were matched with propensity score matching analysis, and further, the perioperative clinical data of the two groups were compared. RESULTS: Compared with the EH group, patients in the MF group had shorter operative time, lesser intraoperative bleeding, shorter postoperative drainage time, and shorter postoperative hospital stay (P < 0.05). By comparing the intraoperative and postoperative complications in the two groups, it was found that the incidence of intraoperative lymph node fragmentation, the incidence of postoperative celiac disease, and the incidence of postoperative food choking were significantly lower in the MF group than that in the EH group. The increase of CRP, IL-6, IL-8, and TNF-α levels in the MF group was less than that in the EH group. CONCLUSIONS: The use of MF in robotic-assisted thoracoscopic radical lung cancer surgery is safe and effective, with advantages in lymph node dissection, reduced surgical trauma, and fewer postoperative complications.


Assuntos
Neoplasias Pulmonares , Humanos , Resultado do Tratamento , Pontuação de Propensão , Estudos Retrospectivos , Neoplasias Pulmonares/cirurgia , Complicações Pós-Operatórias , Eletrocoagulação , Instrumentos Cirúrgicos , Cirurgia Torácica Vídeoassistida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA