Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
NMR Biomed ; 36(7): e4901, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36632695

RESUMO

The purpose of the current study was to develop spatially and velocity-selective (SVS) magnetization preparation pulses for noncontrast-enhanced peripheral MR angiography (MRA) to provide comparisons with velocity-selective (VS) MRA with comparison to velocity-selective (VS). VS preparation pulses were designed by concatenating multiple excitation steps, each of which was a combination of a hard RF pulse, VS unipolar gradient pulses, and refocusing RF pulses. SVS preparation pulses were designed by replacing the hard RF pulse with a sinc-shaped RF pulse combined with a symmetric tripolar gradient pulse (which does not perturb the velocity encoding by the VS unipolar gradient pulses). Numerical simulations were performed to verify the intended hybrid excitation selectivity of SVS pulses taking account of tissue relaxation, magnetic field errors, and eddy currents. In vivo experiments were performed in healthy subjects to verify the hybrid excitation selectivity, as well as to demonstrate the visualization of the entire peripheral arteries using six-station protocols. As demonstrated by numerical simulations, SVS preparation yielded a notch-shaped longitudinal magnetization (Mz )-velocity response within the spatial stopband (the same as VS preparation) and preserved the Mz of spins outside the stopband, regardless of its velocity. We confirmed these observations also through in vivo tests with good agreement in normalized arterial and muscle signal intensities. In six-station peripheral MRA experiments, the proposed SVS-MRA yielded significantly higher arterial signal-to-noise ratio (SNR) (51.6 ± 14.3 vs. 38.9 ± 10.9; p < 0.001) and contrast-to-noise ratio (CNR) (41.2 ± 13.0 vs. 31.3 ± 10.5; p < 0.001) compared with VS-MRA. The proposed SVS-MRA improves arterial SNR and CNR compared with VS-MRA by mitigating undesired presaturation of arterial blood upstream the imaging field of view.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Razão Sinal-Ruído
2.
Magn Reson Imaging ; 94: 80-88, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36122676

RESUMO

To develop and validate a novel noncontrast time-resolved magnetic resonance angiography (NC TR-MRA) using consecutive beam pulses with variable flip angles for visualizing hemodynamics in the pulmonary artery, we performed phantom and volunteer studies and applied the novel NC TR-MRA to a 51-year-old woman with pulmonary arteriovenous malformation (PAVM).The novel NC TR-MRA sequence utilized consecutive multiple-beam saturation pulses with variable flip angles considering venous blood T1 relaxation to alter the visualized blood signal length. The flowing blood signal length is suppressed according to the number of beam saturation pulses. NC TR-MRA in each flow phase was assessed by subtracting the images with and without beam saturation pulses. In the flow phantom study, three flow velocities were used to simulate physiological pulmonary arterial blood flow. Signal profiles along the flow direction were evaluated in each flow phase. In the volunteer study, five healthy volunteers were recruited, and NC TR-MRA was applied to evaluate relationships between the flow-saturated time and signal enhancement rates. Four regions of interest (ROIs) were determined on the proximal and distal portions of the right basal artery. A patient with PAVM was included to validate whether a PAVM lesion could be visualized using NC TR-MRA. The visualized flow signal lengths extended proportionally with the number of beam saturation pulses in the steady-flow phantom at all velocities. In the volunteer study, NC TR-MRA images showed signal enhancement from the proximal to distal portions of the right basal artery with increase in the flow-saturated time. Signal enhancement rates in all ROIs were significantly positively correlated with the flow-saturated time (p < 0.001 in all ROIs). Further, the lesion and its hemodynamics could be explicitly visualized in the patient with PAVM. Hence, NC TR-MRA using beam saturation pulse can visualize the hemodynamics of the pulmonary artery and may be useful for diagnosing and following patients with PAVM.


Assuntos
Angiografia por Ressonância Magnética , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Artéria Pulmonar/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA