RESUMO
The difference between the shear performances of Perfobond Leiste (PBL) shear connectors embedded in steel fiber-reinforced cementitious composite (SFRCC) structure and normal strength concrete (NC) structure was investigated by push-out tests and finite element (FE) simulations. Push-out tests were carried out on nine steel-SFRCC specimens and nine steel-NC specimens. The mechanical behavior of the PBL shear connector was examined according to the failure modes, load-slip curves, and strain distribution laws of the push-out specimens. Experimental results revealed that the extension of cracks in SFRCC was hindered by steel fibers, and the number and width of cracks in SFRCC were smaller than those in NC. The failure mode of the steel-SFRCC specimens and the single-hole steel-NC specimens was the shear failure of the penetrating reinforcement, whereas that of the multi-hole NC specimens was concrete slab cracking. The ultimate shear bearing capacity of PBL shear connectors in the steel-SFRCC specimens was 47.8% greater than that in the steel-NC specimens. Furthermore, an FE model verified by the test results was established to conduct parametric analyses. It was found that the hole diameter and thickness of the steel plate and the yield strength of the penetrating rebar greatly affected the shear bearing capacity of PBL shear connectors. Finally, based on the experimental and FE simulation results, an expression for calculating the ultimate shear bearing capacity of PBL shear connectors in the steel-SFRCC composite structure was developed by considering the bearing effects of concrete dowels, penetrating rebars, and end parts.
RESUMO
Perfobond rib (PBL) shear connectors, made up of the perforated steel plates with the penetrating rebars passing through the holes, are extensively adopted in steel-concrete composite structures for their excellent performance. The adequate understanding of mechanical properties for PBL connectors is of great significance for their reasonable design. In this study, a push out experiment, including 12 specimens with the parameters of concrete strength, diameter of penetrating rebars and the number of holes on perforated steel plate, was performed to explore the mechanical behavior of PBL connectors with steel fiber high strength concrete (SFHSC). The experimental results showed that the shear capacity of the PBL connectors increased with the increase in concrete strength, diameter of the penetrating rebars and the number of holes. Furthermore, a general prediction formula for the shear capacity of PBL connectors was developed, which considers the shear contribution of concrete dowels, concrete end-bearing, interfacial bonding between the perforated steel plates and concrete and the penetrating rebars as well as the enhancement effect of steel fibers. The prediction results of the equation are in good agreement with the experimental data and could provide a reference for the design of PBL connectors.