RESUMO
BACKGROUND: For over three decades, digital technologies have been used in Implant Dentistry, beginning with the introduction of planning software for Static Computer-Assisted Implant Surgery (S-CAIS). During this time, this field has witnessed the emergence of diverse methodologies and a proliferation of technological advancements. Today, S-CAIS is a widely adopted procedure for the placement of dental implants in both partially and fully edentulous patients, with Dynamic Computer-Assisted Surgery (D-CAIS) and Robotic-Assisted Implant Surgery (RAIS) rapidly gaining attention among dental professionals. The continuous advancements in this arena are not merely indicative of technological progress; they represent a steadfast dedication to refining precision, enhancing efficiency, and fostering innovation with the goal of optimizing patient outcomes in dental implantology. AIMS: The purpose of the following review is to meticulously examine the spectrum of digital technologies available and to describe their protocols, advantages, and shortcomings as well as to evaluate their accuracy in implant surgery in patients with complete edentulism. MATERIALS AND METHODS: A scoping review was performed following the Joanna Briggs Institute (JBI) protocols, leveraging the population, concept, and context (PCC) framework to construct the research question and determine the inclusion and exclusion criteria. RESULTS: Two hundred and sixty-seven records were identified for screening. After applying all the screening criteria, 41 articles were included for review and qualitative data analysis. DISCUSSION: S-CAIS, D-CAIS, and RAIS were identified as the main technologies for computer assisted implant surgery. Their applications, characteristics, protocols and levels of accuracy were compared and described. CONCLUSION: Taking into consideration the limitations of this study, S-CAIS appears to be the most applied and validated technology in implant surgery for fully edentulous patients followed by D-CAIS and RAIS being these last two promising initiatives in the field. Despite having similar levels of accuracy, the overall comparison showed a slightly higher values in RAIS followed by D-CAIS and S-CAIS.
Assuntos
Implantação Dentária Endóssea , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Boca Edêntula/cirurgia , Implantação Dentária Endóssea/métodos , Tecnologia Digital , Procedimentos Cirúrgicos Robóticos/métodos , Implantes DentáriosRESUMO
OBJECTIVES: This retrospective study was intended to evaluate the clinical accuracy of partially guided template in guiding implant placement in edentulous patients. METHODS: A total of 120 implants were placed in 24 patients with at least one completely edentulous arch with a partially guided system. Based on CBCT data, a repeatable method was used to measure linear and angular deviations of implants at 3D level in Mimics medical software. The influence of supporting tissue and implant region on the accuracy was assessed, followed by the evaluation of direction of linear deviations in biologically vital areas. RESULTS: Linear deviations of all implants were 1.91 ± 0.68 mm, 1.47 ± 0.68 mm, and 1.02 ± 0.69 mm at apical, apical lateral, and apical vertical levels. When at the cervical, cervical lateral, and cervical vertical levels, the linear deviations were 1.53 ± 0.65 mm, 0.98 ± 0.53 mm, and 1.01 ± 0.69 mm, respectively. Angular deviation of all implants was 7.14 ± 3.41°. Implants guided by mucosa + tooth-supported templates showed higher linear deviations at apical vertical level (1.21 ± 0.72 mm vs. 0.86 ± 0.63 mm, p < .05) and cervical vertical level (1.18 ± 0.72 mm vs. 0.87 ± 0.63 mm, p < .05) than mucosa-supported templates, and implants in maxilla were found higher angular deviation than mandible (7.89 ± 3.61° vs. 6.29 ± 2.97°, p < .05). CONCLUSIONS: The partially guided template served as clinically viable surgical assistance in implant placement in edentulous patients. When using mucosa + tooth-supported template or placing implants in maxilla, more caution was required, especially in biologically vital areas.
Assuntos
Implantes Dentários , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico , Cirurgia Assistida por Computador/métodos , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Desenho Assistido por Computador , Imageamento TridimensionalRESUMO
OBJECTIVES: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. MATERIALS AND METHODS: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. RESULTS: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). CONCLUSIONS: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.
Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Fotogrametria , Fotogrametria/métodos , Humanos , Técnicas In Vitro , Modelos Dentários , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Implantes Dentários , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Planejamento de Prótese DentáriaRESUMO
BACKGROUND: Graftless sinus floor augmentation shows good results in bone gain, radiology and implant survival. Clinically, this technique can be recommended as an alternative to conventional procedures using augmentation materials. OBJECTIVES: This study aims to assess masticatory performance, masticatory ability and patient satisfaction after graftless sinus floor augmentation. METHODS: The study group consisted of patients who had received a graftless sinus lift procedure in a split-mouth design and was compared to patients with maxillary implant-supported overdentures without augmentation and a natural dentition group. To assess objective masticatory performance, the mixing ability test was performed. Three questionnaires were used to assess patient reported outcomes related to mastication and patient satisfaction. RESULTS: Each group included ten patients. Both the graftless sinus lift group and the edentulous control group had a worse masticatory performance compared to the natural dentition group. Masticatory ability, measured by patient reported outcomes, was not different between the graftless sinus floor augmentation group and implant-retained overdentures group without augmentation, but the natural dentition group showed better results. Thereby, the better the masticatory performance in patients with a graftless sinus membrane elevation the better the patient satisfaction for 'prosthesis', 'appearance of prostheses', 'speech' and 'mastication and eating'. CONCLUSIONS: Patients with implant-supported overdentures show inferior masticatory function compared to those with natural dentition. There were no significant differences in masticatory performance between patients with implant-retained overdentures, with or without graftless augmentation. The decision on the preferred procedure should consider additional factors such as anatomical, surgical-technical aspects and patient's preferences.
Assuntos
Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Mastigação , Satisfação do Paciente , Levantamento do Assoalho do Seio Maxilar , Humanos , Mastigação/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Levantamento do Assoalho do Seio Maxilar/métodos , Idoso , Boca Edêntula/reabilitação , Boca Edêntula/cirurgia , Boca Edêntula/fisiopatologia , Resultado do TratamentoRESUMO
Rehabilitation of the edentulous maxilla with implant-supported fixed dental prostheses can represent a significant clinical challenge due to limited bone availability and surgical access, among other factors. This review addresses several treatment options to replace missing teeth in posterior maxillary segments, namely the placement of standard implants in conjunction with maxillary sinus floor augmentation, short implants, tilted implants, and distal cantilever extensions. Pertinent technical information and a concise summary of relevant evidence on the reported outcomes of these different therapeutic approaches are presented, along with a set of clinical guidelines to facilitate decision-making processes and optimize the outcomes of therapy.
Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Levantamento do Assoalho do Seio Maxilar , Humanos , Implantação Dentária Endóssea , Maxila/cirurgia , Planejamento de Prótese Dentária , Boca Edêntula/cirurgia , Prótese Dentária Fixada por Implante , Arcada Edêntula/reabilitação , Resultado do TratamentoRESUMO
OBJECTIVES: The aim of Working Group 4 was to address patient benefits associated with implant dentistry. Focused questions on (a) dental patient-reported outcomes (dPROs), (b) improvement in orofacial function, and (c) preservation of orofacial tissues in partially and fully edentulous patients following provision of implant-retained/supported dental prostheses were addressed. MATERIALS AND METHODS: Three systematic reviews formed the basis for discussion. Participants developed statements and recommendations determined by group consensus based on the findings of the systematic reviews. These were then presented and accepted following further discussion and modifications as required by the plenary of the 7th ITI Consensus Conference, taking place in 2023 in Lisbon, Portugal. RESULTS: Edentulous patients wearing complete dentures (CD) experience substantial improvements in overall dPROs and orofacial function following treatment with either complete implant-supported fixed dental prostheses (CIFDP) or implant overdentures (IODs). With respect to dPROs, mandibular IODs retained by two implants are superior to IODs retained by one implant. However, increasing the number of implants beyond two, does not further improve dPROs. In fully edentulous patients, rehabilitation with CIFDP or IOD is recommended to benefit the preservation of alveolar bone and masseter muscle thickness. CONCLUSIONS: Completely edentulous patients benefit substantially when at least the mandible is restored using an CIFDP or an IOD compared to CD. In fully edentulous patients, implant prostheses are the best option for tooth replacement. The availability of this treatment modality should be actively promoted in all edentulous communities, including those with limited access and means.
Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Boca Edêntula/cirurgia , Prótese Total , Consenso , Revestimento de DentaduraRESUMO
OBJECTIVES: This review evaluated the effects of rehabilitation with implant-supported prostheses on the oral function of completely edentulous adults. MATERIALS AND METHODS: Systematic literature searches were performed to identify records reporting on oral function in completely edentulous adults rehabilitated with implant-supported prostheses. Meta-analyses were performed on various outcomes including bite force, masticatory performance, muscle activity, mandibular movement/chewing pattern, and salivary flow. RESULTS: 5507 records were identified. Thirty studies qualified for data extraction and analysis. The kappa (ð) for the search and identification strategy ranged between 0.50 and 1.00. Meta-analysis was performed grouping the studies by outcomes and split by time points of 6-12 months, 12-36 months, and >36 months after implant therapy. The meta-analyses revealed a significant improvement in oral function of completely edentulous adults after rehabilitation with implant-supported prostheses at 6-12 months (Z = -4.895, p < .001; 95% CI: -0.703, -0.301; τ2 = .609; Q = 114.953, df = 17, p < .001; I2 = 85.2%), at 12-36 months (Z = -4.886, p < .001; 95% CI: -0.580, -0.248; τ2 = .908; Q = 280.611, df = 35, p < .001; I2 = 87.5%) and at more than 36 months (Z = -9.108, p < .001; 95% CI: -1.472, -0.951; τ2 = .019; Q = 7.918, df = 7, p = .340; I2 = 11.6%). The included studies demonstrated a low to moderate risk of bias. CONCLUSIONS: This systematic review concluded that the oral function of completely edentate adults significantly improved with implant-supported/retained prostheses, even when only one jaw received implant therapy. Therefore, implant therapy should be promoted for edentulous adults to alleviate the shortcomings of conventional complete removable dental prostheses.
Assuntos
Implantes Dentários , Boca Edêntula , Adulto , Humanos , Prótese Dentária Fixada por Implante , Força de Mordida , Mandíbula , Mastigação , Boca Edêntula/cirurgiaRESUMO
OBJECTIVES: To analyze the effect of implant treatment in edentulous patients rehabilitated with implant-supported fixed complete dentures (IFCDs) or implant overdentures (IODs) on dental patient-reported outcomes (dPROs). MATERIALS AND METHODS: In January 2022, Medline, Embase, CINAHL, Cochrane Library, PubMed Central, Web of Science, and ClinicalTrials.gov were screened for prospective clinical studies on completely edentulous patients treated with IFCDs and/or IODs, reporting pre-treatment and follow-up dPROs. Hedges' g effect sizes (ES) with corresponding 95% confidence intervals (CI) were calculated. Afterward, meta-analyses were conducted using random effect models. RESULTS: A total number of 1608 records was initially identified. Of those, 28 studies reporting dPROs from 1457 patients were finally included. The applied dental patient-reported outcome measures (dPROMs) included several versions of the Oral Health Impact Profile (OHIP) or specific items assessing satisfaction with Visual Analogue Scales (VAS). The overall ES was large for rehabilitation with IFCDs (1.68 [CI: 1.15, 2.20]) and IODs (1.26 [CI: 0.99, 1.52]) with no significant difference (p = .165) between the two. Denture stability was the only factor rated significantly higher for IFCDs (ES difference: 2.37 [CI: 0.21, 4.54]; p = .032). Subgroup analyses revealed moderately higher ES for IODs on two implants relative to one implant (ES difference: 0.73 [CI: 0.34, 1.12]; p < .001). CONCLUSIONS: There is a strong positive effect of implant treatment in edentulous patients, independent of the type of prosthetic rehabilitation. In patients seeking high stability, IFCDs may be preferable. In mandibular IODs on a single implant, there was a significantly positive effect of an additional implant on dPROs.
Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Revestimento de Dentadura , Estudos Prospectivos , Prótese Total , Boca Edêntula/cirurgia , Medidas de Resultados Relatados pelo PacienteRESUMO
OBJECTIVES: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo. MATERIALS AND METHODS: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (α = .05). RESULTS: Total mean linear deviation within the CS group was 189 µm without scan aid and 135 µm when using the scan aid. The TR group's total mean deviation was 165 µm with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p = .001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR-SA group compared to 86% for the TR-NO group, 83% for the CS-SA, and 70% for the CS-NO group, respectively. CONCLUSIONS: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.
Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Imageamento Tridimensional , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Modelos Dentários , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgiaRESUMO
OBJECTIVES: This study evaluated the accuracy of dental implant placement using the robotic computer-assisted implant surgery (r-CAIS) technology in fully edentulous patients. MATERIALS AND METHODS: Fully edentulous and terminal dentition patients were enrolled for r-CAIS technology. Based on the cone-beam computed tomography (CBCT) examination, a customized positioning marker and a preoperative surgical plan were created before surgery. During the implant surgery, the implant osteotomy and placement were automatically performed using an autonomous robotic surgery system under the surgeon's supervision. A postoperative CBCT scan was used to determine the discrepancies between the planned and placed implants. RESULTS: Ten patients with 59 implants underwent autonomous robotic surgery. No adverse surgical events occurred. The deviations of global coronal, global apical, and angular were 0.67 ± 0.37 mm (95% CI: 0.58-0.77 mm), 0.69 ± 0.37 mm (95% CI: 0.59-0.78 mm), and 1.27° ± 0.59° (95% CI: 1.42°-1.11°), respectively. CONCLUSIONS: The autonomous r-CAIS technology proved an accurate surgical approach for implant placement in fully edentulous patients due to the control of the angular deviation. Autonomous robotic surgery seems promising as an accurate technology for treating fully edentulous patients. However, further trials are required to provide more hard clinical evidence.
Assuntos
Implantes Dentários , Boca Edêntula , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Desenho Assistido por Computador , Boca Edêntula/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico , Imageamento TridimensionalRESUMO
OBJECTIVES: This clinical study aimed to assess the accuracy of implant positions using a robotic system in partially edentulous patients. MATERIALS AND METHODS: Twenty-eight partially edentulous patients received 31 implants using the robotic system. Deviations between the planned and placed implants were calculated after surgery. The deviations were compared with objective performance goals (OPGs) from reported studies of fully guided static computer-assisted implant surgery (CAIS) and dynamic CAIS. A multiple linear regression analysis was performed to investigate the possible effects of the type and side of the arch, implant location, and implant dimensions on the deviations. RESULTS: The evaluation of 31 implants resulted in a mean angle deviation of 2.81 ± 1.13° (95% confidence interval (CI): 2.40-3.23°), while the 3D deviations at the implant shoulder and apex were 0.53 ± 0.23 mm (95% CI 0.45-0.62 mm) and 0.53 ± 0.24 mm (95% CI 0.44-0.61 mm), respectively. The upper limits of the 95% CI of 3D deviations were lower than those of the corresponding OPGs; however, the angle deviation was similar to that of the OPG. No statistically significant differences were found for the type and side of the arch, implant location, and implant dimensions to the deviations (p > .05). CONCLUSIONS: The robotic system appears to achieve higher accuracy in implant positions than static and dynamic CAIS in partially edentulous patients (Chinese Clinical Trial Registry ChiCTR2300067587).
Assuntos
Implantes Dentários , Boca Edêntula , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Estudos Prospectivos , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional , Planejamento de Assistência ao Paciente , Boca Edêntula/cirurgia , Cirurgia Assistida por Computador/métodosRESUMO
OBJECTIVES: Multiple generations of medical robots have revolutionized surgery. Their application to dental implants is still in its infancy. Co-operating robots (cobots) have great potential to improve the accuracy of implant placement, overcoming the limitations of static and dynamic navigation. This study reports the accuracy of robot-assisted dental implant placement in a preclinical model and further applies the robotic system in a clinical case series. MATERIALS AND METHODS: In model analyses, the use of a lock-on structure at robot arm-handpiece was tested in resin arch models. In a clinical case series, patients with single missing teeth or edentulous arch were included. Robot-assisted implant placement was performed. Surgery time was recorded. Implant platform deviation, apex deviation, and angular deviation were measured. Factors influencing implant accuracy were analyzed. RESULTS: The in vitro results showed that with a lock-on structure, the mean (SD) of platform deviation, apex deviation, and angular deviation were 0.37 (0.14) mm, 0.44 (0.17) mm, and 0.75 (0.29)°, respectively. Twenty-one patients (28 implants) were included in the clinical case series, 2 with arches and 19 with single missing teeth. The median surgery time for single missing teeth was 23 (IQ range 20-25) min. The surgery time for the two edentulous arches was 47 and 70 min. The mean (SD) of platform deviation, apex deviation, and angular deviation was 0.54 (0.17) mm, 0.54 (0.11) mm, and 0.79 (0.22)° for single missing teeth and for 0.53 (0.17) mm, 0.58 (0.17) mm, and 0.77 (0.26)° for an edentulous arch. Implants placed in the mandible had significantly larger apex deviation than those in the maxilla. CONCLUSION: Cobot-assisted dental implant placement showed excellent positional accuracy and safety in both the in vitro study and the clinical case series. More technological development and clinical research are needed to support the introduction of robotic surgery in oral implantology. Trial registered in ChiCTR2100050885.
Assuntos
Implantes Dentários , Boca Edêntula , Robótica , Cirurgia Assistida por Computador , Perda de Dente , Humanos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Tecnologia Háptica , Imageamento Tridimensional , Boca Edêntula/cirurgia , Cirurgia Assistida por Computador/métodosRESUMO
OBJECTIVES: To evaluate the accuracy of implant placement using a dynamic navigation system in fully edentulous jaws and to analyze the influence of implant distribution on implant position accuracy. MATERIALS AND METHODS: Edentulous patients who received implant placement using a dynamic navigation system were included. Four to six mini screws were placed in the edentulous jaw under local anesthesia as fiducial markers. Then patients received CBCT scans. Virtual implant positions were designed in the planning software based on CBCT data. Under local anesthesia, implants were inserted under the guidance of the dynamic navigation system. CBCTs were taken following implant placement. The deviation between the actual and planned implant positions was measured by comparing the pre- and postsurgery CBCT. RESULTS: A total of 13 edentulous patients with 13 edentulous maxillae and 7 edentulous mandibles were included, and 108 implants were placed. The average linear deviations at the implant entry point and apex were 1.08 ± 0.52 mm and 1.15 ± 0.60 mm, respectively. The average angular deviation was 2.85 ± 1.20°. No significant difference was detected in linear and angular deviations between the maxillary and mandibular implants, neither between the anterior and posterior implants. CONCLUSIONS: The dynamic navigation system provides high accuracy for implant placement in fully edentulous jaws, while the distribution of the implants showed little impact on implant position accuracy.
Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Computadores , Desenho Assistido por Computador , Imageamento TridimensionalRESUMO
OBJECTIVES: This study aimed to compare implant positioning accuracy and patient-centered results between static and dynamic computer-assisted implant surgery (s-CAIS and d-CAIS) in edentulous jaws. MATERIAL AND METHODS: The current study retrospectively evaluated a total of 110 implants placed in 22 fully edentulous patients via s-CAIS or d-CAIS (n = 11). The accuracy of implant positioning was assessed by measuring the implant's angular deviation and deviation at the platform and apex from the preoperative design postoperatively. Patient-centered results, including preoperative and intraoperative patient-reported experiences and postoperative patient-reported outcomes, were extracted from the medical records. The nested t test and chi-square test were used to compare accuracy and patient-centered results between s-CAIS and d-CAIS postoperatively. RESULTS: The implants in the s-CAIS group showed significantly smaller angular deviation (2.32 ± 1.23°) than those in the d-CAIS group (3.87 ± 2.75°). In contrast, the platform and apical deviation were significantly larger in s-CAIS (1.56 ± 1.19 mm and 1.70 ± 1.09 mm, respectively) than d-CAIS (1.02 ± 0.45 mm and 1.00 ± 0.51 mm, respectively). Furthermore, the implants in the s-CAIS group deviated significantly (p < 0.001) more toward the coronal direction than those in the d-CAIS group. Notably, all patients in the s-CAIS group reported an obvious foreign body sensation during surgery, representing a significant difference from the d-CAIS group. CONCLUSIONS: Compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation and less foreign body sensation. TRIAL REGISTRATION: The retrospective study was registered on the Chinese Clinical Trial Registry on August 8th, 2022, with registration number No. ChiCTR2200062484. CLINICAL RELEVANCE: Despite the increasing use of computer- assisted implant surgery in fully edentulous patients, clinical evidence comparing implant positioning accuracy and patient-centered results between static and dynamic CAIS systems is scarce. Our study demonstrated that compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation.
Assuntos
Implantes Dentários , Corpos Estranhos , Arcada Edêntula , Boca Edêntula , Humanos , Estudos Retrospectivos , Arcada Edêntula/cirurgia , Boca Edêntula/cirurgia , Assistência Centrada no Paciente , ComputadoresRESUMO
Mandibular flexure is a phenomenon characterized by a reduction of the arch width caused by the action of various muscular groups involved during mastication. When flexure is pronounced and teeth or dental implants are rigidly splinted, mandibular flexure leads to a biomechanical environment detrimental to the longevity of the restoration. This clinical report presents the use of a dental plaster device as a diagnostic tool to determine the extent of mandibular flexure in an edentulous patient treated with a mandibular fixed complete denture.
Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Mandíbula , Prótese Total , Boca Edêntula/cirurgia , Gravação em Vídeo , Prótese Dentária Fixada por ImplanteRESUMO
The treatment of complete or single arch edentulism remains a significant priority for dental clinicians. Patients often request immediate loading for complex complete arch treatments with shorter treatment times and fewer appointments, and digital technologies can be leveraged to provide more effective treatments. This part 1 presentation focuses on the discussion of commonly seen complications related to using digital technologies in treating edentulous patients during the data collection and surgical planning stages. Complications related to digital technologies can be prevented or corrected during these stages, preventing future complications in the clinical (surgical and prosthetic) stages.
Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Arcada Edêntula , Boca Edêntula , Humanos , Arcada Edêntula/cirurgia , Tecnologia Digital , Boca Edêntula/cirurgia , Resultado do Tratamento , Prótese Dentária Fixada por ImplanteRESUMO
This is the second part of a JPD Digital presentation focusing on commonly seen complications and solutions related to using digital technologies in treating edentulous patients during the surgical and prosthetic stages. The proper usage of the computer-aided design and computer-aided manufacturing surgical templates and immediate loading prosthesis during computer-guided surgery and accurate translation of digital planning into clinical execution are discussed. In addition, design concepts of implant-supported complete fixed dental prostheses are presented to minimize subsequent issues in their long-term clinical service. In concert with these topics, this presentation will allow clinicians to deepen their understanding of the advantages and limitations of utilizing digital technologies in implant dentistry.
Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Arcada Edêntula , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Tecnologia Digital , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Implantação Dentária Endóssea , Boca Edêntula/cirurgia , Desenho Assistido por Computador , Computadores , Arcada Edêntula/cirurgiaRESUMO
STATEMENT OF PROBLEM: The direct digitalization of completely edentulous arches rehabilitated with multiple implants still represents a limitation regarding obtaining accurate images for prosthetic purposes. PURPOSE: The purpose of this systematic review was to present the factors that may influence the accuracy of intraoral scanning of completely edentulous arches. MATERIAL AND METHODS: This review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and registered with International Prospective Register of Systematic Reviews (PROSPERO) (CRD42020171021). Three examiners performed an electronic search in the Medline/PubMed, Cochrane Library, Scopus, and Web of Science databases for articles published up to January 2021. RESULTS: The electronic search resulted in 11 498 studies. After removing duplicates, 11 347 studies remained. Twelve studies were selected (10 in vitro and 2 in vivo) according to the eligibility criteria. Several factors were found to influence the performance of intraoral scanners (Carestream Dental and TRIOS, 3Shape presented the best results), the intraoral scanning technique (Promoting physical paths that join the digitization bodies can increase the accuracy of transferring the position of the implants), environmental conditions (temperature: 20 °C to 21 °C, air pressure: 750 to 760 ±5 mmHg, air humidity: 45%, angle and distance between the implants: up to 15 degrees and 16 to 22 mm, and the material of the scan body: PEEK more accurate). CONCLUSIONS: The accuracy of the intraoral scanning of completely edentulous arches is affected by factors such as the type of intraoral scanner, scanning technique, environmental conditions, angle and distance between implants, and material of the scan bodies.
Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Imageamento Tridimensional , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Modelos Dentários , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgiaRESUMO
STATEMENT OF PROBLEM: A less invasive and more convenient workflow is needed for dynamic navigation-guided implant surgery for the edentulous arch. PURPOSE: The purpose of this in vitro study was to evaluate the accuracy of a novel dynamic navigation device developed for the completely edentulous mandible. MATERIAL AND METHODS: Two temporary 1-piece mini-implants were placed in the anterior region of a completely edentulous mandibular model for fixation of the navigation device. A total of 40 implants were inserted in 10 completely edentulous mandibular models with the aid of the dynamic navigation device. The accuracy of placement was determined by overlapping the preoperative plan with the postoperative cone beam computed tomography (CBCT) scans. The difference in the accuracy at different implant positions was compared by MANOVA and Bonferroni-corrected ANOVAs. The difference in accuracy between implants #1-20 and #21-40 was assessed for learning progression. RESULTS: The deviation of the implants (mean ±standard deviation) was 1.14 ±0.50 mm at the entry point and 1.29 ±0.48 mm at the apex. The mean ±standard deviation angular deviation was 3.02 ±1.32 degrees. No significant difference was seen between the planned and the placed deviation among the 4 implant positions. After repeated placement with this dynamic approach, implant accuracy at the entry (P=.001) and apex (P=.017) improved significantly. CONCLUSIONS: The navigation device achieved acceptable implant placement accuracy in the edentulous mandible. Deviations between the planned and placed locations were not affected by different implant positions. After repeated operations with this dynamic approach, accuracy at the entry and apex improved significantly.
Assuntos
Implantes Dentários , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Cirurgia Assistida por Computador/métodos , Desenho Assistido por Computador , Boca Edêntula/cirurgia , Tomografia Computadorizada de Feixe Cônico , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Imageamento TridimensionalRESUMO
Complete arch immediate-loading implant-supported prostheses can represent a major challenge for the patient and the dental team. Obtaining stable references and an accurate occlusal record after implant placement to provide an interim prosthesis is a difficult task and can deviate from the initial treatment plan. The described technique presents a fully digital protocol to provide an immediate complete arch implant-supported fixed interim prosthesis for edentulous patients by making postoperative cone beam computed tomography and intraoral digital scans that correlate with the previous plan.