Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41.306
Filtrar
Mais filtros

Coleção CLAP
Intervalo de ano de publicação
1.
Nature ; 613(7945): 667-675, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697864

RESUMO

Continuous imaging of cardiac functions is highly desirable for the assessment of long-term cardiovascular health, detection of acute cardiac dysfunction and clinical management of critically ill or surgical patients1-4. However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness5-11, and existing wearable cardiac devices can only capture signals on the skin12-16. Here we report a wearable ultrasonic device for continuous, real-time and direct cardiac function assessment. We introduce innovations in device design and material fabrication that improve the mechanical coupling between the device and human skin, allowing the left ventricle to be examined from different views during motion. We also develop a deep learning model that automatically extracts the left ventricular volume from the continuous image recording, yielding waveforms of key cardiac performance indices such as stroke volume, cardiac output and ejection fraction. This technology enables dynamic wearable monitoring of cardiac performance with substantially improved accuracy in various environments.


Assuntos
Ecocardiografia , Desenho de Equipamento , Coração , Dispositivos Eletrônicos Vestíveis , Humanos , Débito Cardíaco , Ecocardiografia/instrumentação , Ecocardiografia/normas , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Dispositivos Eletrônicos Vestíveis/normas , Pele
2.
Circulation ; 149(15): 1172-1182, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38410954

RESUMO

BACKGROUND: Recent guidelines redefined exercise pulmonary hypertension as a mean pulmonary artery pressure/cardiac output (mPAP/CO) slope >3 mm Hg·L-1·min-1. A peak systolic pulmonary artery pressure >60 mm Hg during exercise has been associated with an increased risk of cardiovascular death, heart failure rehospitalization, and aortic valve replacement in aortic valve stenosis. The prognostic value of the mPAP/CO slope in aortic valve stenosis remains unknown. METHODS: In this prospective cohort study, consecutive patients (n=143; age, 73±11 years) with an aortic valve area ≤1.5 cm2 underwent cardiopulmonary exercise testing with echocardiography. They were subsequently evaluated for the occurrence of cardiovascular events (ie, cardiovascular death, heart failure hospitalization, new-onset atrial fibrillation, and aortic valve replacement) during a follow-up period of 1 year. Findings were externally validated (validation cohort, n=141). RESULTS: One cardiovascular death, 32 aortic valve replacements, 9 new-onset atrial fibrillation episodes, and 4 heart failure hospitalizations occurred in the derivation cohort, whereas 5 cardiovascular deaths, 32 aortic valve replacements, 1 new-onset atrial fibrillation episode, and 10 heart failure hospitalizations were observed in the validation cohort. Peak aortic velocity (odds ratio [OR] per SD, 1.48; P=0.036), indexed left atrial volume (OR per SD, 2.15; P=0.001), E/e' at rest (OR per SD, 1.61; P=0.012), mPAP/CO slope (OR per SD, 2.01; P=0.002), and age-, sex-, and height-based predicted peak exercise oxygen uptake (OR per SD, 0.59; P=0.007) were independently associated with cardiovascular events at 1 year, whereas peak systolic pulmonary artery pressure was not (OR per SD, 1.28; P=0.219). Peak Vo2 (percent) and mPAP/CO slope provided incremental prognostic value in addition to indexed left atrial volume and aortic valve area (P<0.001). These results were confirmed in the validation cohort. CONCLUSIONS: In moderate and severe aortic valve stenosis, mPAP/CO slope and percent-predicted peak Vo2 were independent predictors of cardiovascular events, whereas peak systolic pulmonary artery pressure was not. In addition to aortic valve area and indexed left atrial volume, percent-predicted peak Vo2 and mPAP/CO slope cumulatively improved risk stratification.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Ecocardiografia sob Estresse/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Débito Cardíaco , Insuficiência Cardíaca/complicações , Oxigênio
3.
Circ Res ; 133(7): 559-571, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37641938

RESUMO

BACKGROUND: The phrase complete vagal withdrawal is often used when discussing autonomic control of the heart during exercise. However, more recent studies have challenged this assumption. We hypothesized that cardiac vagal activity increases during exercise and maintains cardiac function via transmitters other than acetylcholine. METHODS: Chronic direct recordings of cardiac vagal nerve activity, cardiac output, coronary artery blood flow, and heart rate were recorded in conscious adult sheep during whole-body treadmill exercise. Cardiac innervation of the left cardiac vagal branch was confirmed with lipophilic tracer dyes (DiO). Sheep were exercised with pharmacological blockers of acetylcholine (atropine, 250 mg), VIP (vasoactive intestinal peptide; [4Cl-D-Phe6,Leu17]VIP 25 µg), or saline control, randomized on different days. In a subset of sheep, the left cardiac vagal branch was denervated. RESULTS: Neural innervation from the cardiac vagal branch is seen at major cardiac ganglionic plexi, and within the fat pads associated with the coronary arteries. Directly recorded cardiac vagal nerve activity increased during exercise. Left cardiac vagal branch denervation attenuated the maximum changes in coronary artery blood flow (maximum exercise, control: 63.5±5.9 mL/min, n=8; cardiac vagal denervated: 32.7±5.6 mL/min, n=6, P=2.5×10-7), cardiac output, and heart rate during exercise. Atropine did not affect any cardiac parameters during exercise, but VIP antagonism significantly reduced coronary artery blood flow during exercise to a similar level to vagal denervation. CONCLUSIONS: Our study demonstrates that cardiac vagal nerve activity actually increases and is crucial for maintaining cardiac function during exercise. Furthermore, our findings show the dynamic modulation of coronary artery blood flow during exercise is mediated by VIP.


Assuntos
Acetilcolina , Coração , Animais , Ovinos , Vasos Coronários , Débito Cardíaco , Atropina/farmacologia
4.
J Physiol ; 602(10): 2227-2251, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38690610

RESUMO

Passive whole-body hyperthermia increases limb blood flow and cardiac output ( Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart and Q ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions, Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart and Q ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output: Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow and Q ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmented Q ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.


Assuntos
Débito Cardíaco , Hipertermia , Humanos , Masculino , Adulto , Hipertermia/fisiopatologia , Débito Cardíaco/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Febre/fisiopatologia , Adulto Jovem , Temperatura Alta , Hemodinâmica
5.
Am J Physiol Heart Circ Physiol ; 326(5): H1131-H1137, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38456848

RESUMO

A significant number of pregnancies occur at advanced maternal age (>35 yr), which is a risk factor for pregnancy complications. Healthy pregnancies require massive hemodynamic adaptations, including an increased blood volume and cardiac output. There is growing evidence that these cardiovascular adaptations are impaired with age, however, little is known about maternal cardiac function with advanced age. We hypothesized that cardiac adaptations to pregnancy are impaired with advanced maternal age. Younger (4 mo; ∼early reproductive maturity in humans) and aged (9 mo; ∼35 yr in humans) pregnant Sprague-Dawley rats were assessed and compared with age-matched nonpregnant controls. Two-dimensional echocardiographic images were obtained (ultrasound biomicroscopy; under anesthesia) on gestational day 19 (term = 22 days) and compared with age-matched nonpregnant rats (n = 7-9/group). Left ventricular structure and function were assessed using short-axis images and transmitral Doppler signals. During systole, left ventricular anterior wall thickness increased with age in the nonpregnant rats, but there was no age-related difference between the pregnant groups. There were no significant pregnancy-associated differences in left ventricular wall thickness. Calculated left ventricular mass increased with age in nonpregnant rats and increased with pregnancy only in young rats. Compared with young pregnant rats, the aortic ejection time of aged pregnant rats was greater and Tei index was lower. Overall, the greater aortic ejection time and lower Tei index with age in pregnant rats suggest mildly altered cardiac adaptations to pregnancy with advanced maternal age, which may contribute to adverse outcomes in advanced maternal age pregnancies.NEW & NOTEWORTHY We demonstrated that even before the age of reproductive senescence, rats show signs of age-related alterations in cardiac structure that suggests increased cardiac work. Our data also demonstrate, using an in vivo echocardiographic approach, that advanced maternal age in a rat model is associated with altered cardiac function and structure relative to younger pregnant controls.


Assuntos
Ecocardiografia , Coração , Gravidez , Feminino , Humanos , Ratos , Animais , Idade Materna , Ratos Sprague-Dawley , Coração/diagnóstico por imagem , Débito Cardíaco
6.
Proc Biol Sci ; 291(2025): 20232557, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38889794

RESUMO

Hyperoxia has been shown to expand the aerobic capacity of some fishes, although there have been very few studies examining the underlying mechanisms and how they vary across different exposure durations. Here, we investigated the cardiorespiratory function of yellowtail kingfish (Seriola lalandi) acutely (~20 h) and chronically (3-5 weeks) acclimated to hyperoxia (~200% air saturation). Our results show that the aerobic performance of kingfish is limited in normoxia and increases with environmental hyperoxia. The aerobic scope was elevated in both hyperoxia treatments driven by a ~33% increase in maximum O2 uptake (MO2max), although the mechanisms differed across treatments. Fish acutely transferred to hyperoxia primarily elevated tissue O2 extraction, while increased stroke volume-mediated maximum cardiac output was the main driving factor in chronically acclimated fish. Still, an improved O2 delivery to the heart in chronic hyperoxia was not the only explanatory factor as such. Here, maximum cardiac output only increased in chronic hyperoxia compared with normoxia when plastic ventricular growth occurred, as increased stroke volume was partly enabled by an ~8%-12% larger relative ventricular mass. Our findings suggest that hyperoxia may be used long term to boost cardiorespiratory function potentially rendering fish more resilient to metabolically challenging events and stages in their life cycle.


Assuntos
Consumo de Oxigênio , Perciformes , Animais , Perciformes/fisiologia , Hiperóxia/fisiopatologia , Aclimatação , Oxigênio/metabolismo , Débito Cardíaco
7.
J Transl Med ; 22(1): 285, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493167

RESUMO

BACKGROUND: Lactate is traditionally recognized as a by-product of anaerobic metabolism. However, lactate is a preferred oxidative substrate for stressed myocardium. Exogenous lactate infusion increases cardiac output (CO). The exact mechanism underlying this mechanism has yet to be elucidated. The aim of this study was to investigate the cardiovascular mechanisms underlying the acute haemodynamic effects of exogenous lactate infusion in an experimental model of human-sized pigs. METHODS: In this randomised, blinded crossover study in eight 60-kg-pigs, the pigs received infusions with one molar sodium lactate and a control infusion of tonicity matched hypertonic saline in random order. We measured CO and pulmonary pressures using a pulmonary artery catheter. A pressure-volume admittance catheter in the left ventricle was used to measure contractility, afterload, preload and work-related parameters. RESULTS: Lactate infusion increased circulating lactate levels by 9.9 mmol/L (95% confidence interval (CI) 9.1 to 11.0) and CO by 2.0 L/min (95% CI 1.2 to 2.7). Afterload decreased as arterial elastance fell by  -1.0 mmHg/ml (95% CI  -2.0 to  -0.1) and systemic vascular resistance decreased by  -548 dynes/s/cm5 (95% CI  -261 to  -835). Mixed venous saturation increased by 11 percentage points (95% CI 6 to 16), whereas ejection fraction increased by 16.0 percentage points (95% CI 1.1 to 32.0) and heart rate by 21 bpm (95% CI 8 to 33). No significant changes in contractility nor preload were observed. CONCLUSION: Lactate infusion increased cardiac output by increasing heart rate and lowering afterload. No differences were observed in left ventricular contractility or preload. Lactate holds potential as a treatment in situations with lowered CO and should be investigated in future clinical studies.


Assuntos
Hemodinâmica , Ácido Láctico , Animais , Débito Cardíaco/fisiologia , Estudos Cross-Over , Frequência Cardíaca , Suínos , Resistência Vascular
8.
J Card Fail ; 30(2): 329-336, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37871843

RESUMO

BACKGROUND: Nonintravenous inotropic-delivery options are needed for patients with inotropic-dependent heart failure (HF) to reduce the costs, infections and thrombotic risks associated with chronic central venous catheters and home infusion services. METHODS: We developed a novel, concentrated formulation of nebulized milrinone for inhalation and evaluated the feasibility, safety and pharmacokinetic profile in a prospective, single-arm, phase I clinical trial. We enrolled 10 patients with stage D HF requiring inotropic therapy during a hospital admission for acute HF. Milrinone 60 mg/4 mL was inhaled via nebulization 3 times daily for 48 hours. The coprimary outcomes were adverse events and pharmacokinetic profiles of inhaled milrinone. Acute changes in hemodynamic parameters were secondary outcomes. RESULTS: A concentrated nebulized milrinone formulation was well tolerated, without hypotensive events, arrhythmias or inhalation-related adverse events requiring discontinuation. Nebulized milrinone produced serum concentrations in the goal therapeutic range with a median plasma milrinone trough concentration of 39 (17-66) ng/mL and a median peak concentration of 207 (134-293) ng/mL. There were no serious adverse events. From baseline to 24 hours, mean pulmonary artery saturation increased (60% ± 7%-65 ± 5%; P = 0.001), and mean cardiac index increased (2.0 ± 0.5 mL/min/1.73m2-2.5 ± 0.1 mL/min/1.73m2; P = 0.001) with nebulized milrinone. CONCLUSIONS: In a proof-of-concept study, a concentrated, nebulized milrinone formulation for inhalation was safe and produced therapeutic serum milrinone concentrations. Nebulized milrinone was associated with improved hemodynamic parameters of cardiac output in a population with advanced HF. These promising results require further investigation in a longer-term trial in patients with inotrope-dependent advanced HF.


Assuntos
Insuficiência Cardíaca , Milrinona , Humanos , Milrinona/farmacologia , Milrinona/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Estudos Prospectivos , Hemodinâmica , Débito Cardíaco , Cardiotônicos/uso terapêutico
9.
Anesthesiology ; 140(2): 240-250, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37905995

RESUMO

BACKGROUND: Positive end-expiratory pressure (PEEP) is commonly applied to avoid atelectasis and improve oxygenation in patients during general anesthesia but affects cardiac pressures, volumes, and loading conditions through cardiorespiratory interactions. PEEP may therefore alter stroke work, which is the area enclosed by the pressure-volume loop and corresponds to the external work performed by the ventricles to eject blood. The low-pressure right ventricle may be even more susceptible to PEEP than the left ventricle. The authors hypothesized that increasing levels of PEEP would reduce stroke work in both ventricles. METHODS: This was a prospective, observational, experimental study. Six healthy female pigs of approximately 60 kg were used. PEEP was stepwise increased from 0 to 5, 7, 9, 11, 13, 15, 17, and 20 cm H2O to cover the clinical spectrum of PEEP. Simultaneous, biventricular invasive pressure-volume loops, invasive blood pressures, and ventilator data were recorded. RESULTS: Increasing PEEP resulted in stepwise reductions in left (5,740 ± 973 vs. 2,303 ± 1,154 mmHg · ml; P < 0.001) and right (2,064 ± 769 vs. 468 ± 133 mmHg · ml; P < 0.001) ventricular stroke work. The relative stroke work reduction was similar between the two ventricles. Left ventricular ejection fraction, afterload, and coupling were preserved. On the contrary, PEEP increased right ventricular afterload and caused right ventriculo-arterial uncoupling (0.74 ± 0.30 vs. 0.19 ± 0.13; P = 0.01) with right ventricular ejection fraction reduction (64 ± 8% vs. 37 ± 7%, P < 0.001). CONCLUSIONS: A stepwise increase in PEEP caused stepwise reduction in biventricular stroke work. However, there are important interventricular differences in response to increased PEEP levels. PEEP increased right ventricular afterload leading to uncoupling and right ventricular ejection fraction decline. These findings may support clinical decision-making to further optimize PEEP as a means to balance between improving lung ventilation and preserving right ventricular function.


Assuntos
Função Ventricular Esquerda , Função Ventricular Direita , Humanos , Feminino , Animais , Suínos , Volume Sistólico , Estudos Prospectivos , Função Ventricular Direita/fisiologia , Respiração com Pressão Positiva , Débito Cardíaco
10.
Anesthesiology ; 140(5): 1002-1015, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38157435

RESUMO

BACKGROUND: Thermodilution is unreliable in veno-venous extracorporeal membrane oxygenation (VV-ECMO). Systemic oxygenation depends on recirculation fractions and ratios of extracorporeal membrane oxygenation (ECMO) flow to cardiac output. In a prospective in vitro simulation, this study assessed the diagnostic accuracy of a modified thermodilution technique for recirculation and cardiac output. The hypothesis was that this method provided clinically acceptable precision and accuracy for cardiac output and recirculation. METHODS: Two ECMO circuits ran in parallel: one representing a VV-ECMO and the second representing native heart, lung, and circulation. Both circuits shared the right atrium. Extra limbs for recirculation and pulmonary shunt were added. This study simulated ECMO flows from 1 to 2.5 l/min and cardiac outputs from 2.5 to 3.5 l/min with recirculation fractions (0 to 80%) and pulmonary shunts. Thermistors in both ECMO limbs and the pulmonary artery measured the temperature changes induced by cold bolus injections into the arterial ECMO limb. Recirculation fractions were calculated from the ratio of the areas under the temperature curve (AUCs) in the ECMO limbs and from partitioning of the bolus volume (flow based). With known partitioning of bolus volumes between ECMO and pulmonary artery, cardiac output was calculated. High-precision ultrasonic flow probes served as reference for Bland-Altman plots and linear mixed-effect models. RESULTS: Accuracy and precision for both the recirculation fraction based on AUC (bias, -5.4%; limits of agreement, -18.6 to 7.9%) and flow based (bias, -5.9%; limits of agreement, -18.8 to 7.0%) are clinically acceptable. Calculated cardiac output for all recirculation fractions was accurate but imprecise (RecirculationAUC: bias 0.56 l/min; limits of agreement, -2.27 to 3.4 l/min; and RecirculationFLOW: bias 0.48 l/min; limits of agreement, -2.22 to 3.19 l/min). Recirculation fraction increased bias and decreased precision. CONCLUSIONS: Adapted thermodilution for VV-ECMO allows simultaneous measurement of recirculation fraction and cardiac output and may help optimize patient management with severe respiratory failure.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Termodiluição/métodos , Estudos Prospectivos , Débito Cardíaco , Pulmão
11.
Pediatr Res ; 95(5): 1335-1345, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38177250

RESUMO

BACKGROUND: In the Fontan palliation for single ventricle heart disease (SVHD), pulmonary blood flow is non-pulsatile/passive, low velocity, and low shear, making viscous power loss a critical determinant of cardiac output. The rheologic properties of blood in SVHD patients are essential for understanding and modulating their limited cardiac output and they have not been systematically studied. We hypothesize that viscosity is decreased in single ventricle circulation. METHODS: We evaluated whole blood viscosity, red blood cell (RBC) aggregation, and RBC deformability to evaluate changes in healthy children and SVHD patients. We altered suspending media to understand cellular and plasma differences contributing to rheologic differences. RESULTS: Whole blood viscosity was similar between SVHD and healthy at their native hematocrits, while viscosity was lower at equivalent hematocrits for SVHD patients. RBC deformability is increased, and RBC aggregation is decreased in SVHD patients. Suspending SVHD RBCs in healthy plasma resulted in increased RBC aggregation and suspending healthy RBCs in SVHD plasma resulted in lower RBC aggregation. CONCLUSIONS: Hematocrit corrected blood viscosity is lower in SVHD vs. healthy due to decreased RBC aggregation and higher RBC deformability, a viscous adaptation of blood in patients whose cardiac output is dependent on minimizing viscous power loss. IMPACT: Patients with single ventricle circulation have decreased red blood cell aggregation and increased red blood cell deformability, both of which result in a decrease in blood viscosity across a large shear rate range. Since the unique Fontan circulation has very low-shear and low velocity flow in the pulmonary arteries, blood viscosity plays an increased role in vascular resistance, therefore this work is the first to describe a novel mechanism to target pulmonary vascular resistance as a modifiable risk factor. This is a novel, modifiable risk factor in this patient population.


Assuntos
Viscosidade Sanguínea , Agregação Eritrocítica , Deformação Eritrocítica , Técnica de Fontan , Humanos , Criança , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Masculino , Feminino , Hematócrito , Coração Univentricular/cirurgia , Coração Univentricular/fisiopatologia , Pré-Escolar , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/anormalidades , Débito Cardíaco , Adolescente , Eritrócitos
12.
Eur Radiol ; 34(3): 1825-1835, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37650970

RESUMO

OBJECTIVES: Left ventricle function directly impacts left atrial (LA) conduit function, and LA conduit strain is associated with exercise intolerance in patients with heart failure with preserved ejection fraction (HFpEF). Pulmonary capillary wedge pressure (PCWP) before and during exercise is the current gold standard for diagnosing HFpEF. Post-exercise ΔPCWP can lead to worse long-term outcomes. This study examined the correlation between LA strain and post-exercise ΔPCWP in patients with HFpEF. METHODS: We enrolled 100 subjects, including 74 with HFpEF and 26 with non-cardiac dyspnea, from November 2017 to December 2020. Subjects underwent echocardiography, invasive cardiac catheterization, and expired gas analysis at rest and during exercise. Arterial blood pressure, right atrial pressure, pulmonary artery pressure, and PCWP were recorded during cardiac catheterization. Cardiac output, stroke volume, pulmonary vascular resistance, pulmonary artery compliance, systemic vascular resistance, and LV stroke work were calculated using standard formulas. RESULTS: Exercise LA conduit strain significantly correlated with both post-exercise ΔPCWP (r = - 0.707, p < 0.001) and exercise PCWP (r = - 0.659; p < 0.001). Exercise LA conduit strain differentiated patients who did and did not meet the 2016 European Society of Cardiology HFpEF criteria with an area under the curve of 0.69 (95% confidence interval, 0.548-0.831) using a cutoff value of 14.25, with a sensitivity of 0.64 and a specificity of 0.68. CONCLUSIONS: Exercise LA conduit strain significantly correlates with post-exercise ΔPCWP and has a comparable power to identify patients with HFpEF. Additional studies are warranted to confirm the ability of LA conduit strain to predict long-term outcomes among patients with HFpEF. CLINICAL RELEVANCE STATEMENT: Exercise left atrial conduit strain was highly associated with the difference of post-exercise pulmonary capillary wedge pressure and may indicate increased mortality risk in patients with heart failure with preserved ejection fraction, and also has comparable diagnostic ability. KEY POINTS: • Left atrial conduit strain is associated with exercise intolerance in patients with heart failure with preserved ejection fraction. • Left atrial conduit strain during exercise can identify patients with heart failure with preserved ejection fraction. • Exercise left atrial conduit strain significantly correlates with the difference of pulmonary capillary wedge pressure during and before exercise which might predict the long-term outcomes of heart failure with preserved ejection fraction patients.


Assuntos
Insuficiência Cardíaca , Humanos , Volume Sistólico/fisiologia , Hemodinâmica , Débito Cardíaco/fisiologia , Pressão Propulsora Pulmonar/fisiologia , Função Ventricular Esquerda/fisiologia
13.
Curr Opin Crit Care ; 30(3): 251-259, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690954

RESUMO

PURPOSE OF REVIEW: To describe current and near future developments and applications of CO2 kinetics in clinical respiratory and cardiovascular monitoring. RECENT FINDINGS: In the last years, we have witnessed a renewed interest in CO2 kinetics in relation with a better understanding of volumetric capnography and its derived parameters. This together with technological advances and improved measurement systems have expanded the monitoring potential of CO2 kinetics including breath by breath continuous end-expiratory lung volume and continuous noninvasive cardiac output. Dead space has slowly been gaining relevance in clinical monitoring and prognostic evaluation. Easy to measure dead space surrogates such as the ventilatory ratio have demonstrated a strong prognostic value in patients with acute respiratory failure. SUMMARY: The kinetics of carbon dioxide describe many relevant physiological processes. The clinical introduction of new ways of assessing respiratory and circulatory efficiency based on advanced analysis of CO2 kinetics are paving the road to a long-desired goal in clinical monitoring of critically ill patients: the integration of respiratory and circulatory monitoring during mechanical ventilation.


Assuntos
Capnografia , Dióxido de Carbono , Humanos , Dióxido de Carbono/análise , Capnografia/métodos , Monitorização Fisiológica/métodos , Respiração Artificial/métodos , Cinética , Débito Cardíaco/fisiologia , Biomarcadores , Espaço Morto Respiratório/fisiologia
14.
BJOG ; 131(4): 463-471, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37735094

RESUMO

OBJECTIVE: We defined reference ranges for maternal cardiac output, systemic vascular resistance, and stroke volume measured in the third trimester of pregnancy using the Ultrasound Cardiac Output Monitor 1A. DESIGN: Based on data from the prospective PEACH (PreEclampsia, Angiogenesis, Cardiac dysfunction and Hypertension) cohort study. SETTING: Rigshospitalet and Hvidovre Hospital, Denmark. SAMPLE: Normotensive pregnant women aged 18-45 years with singleton pregnancies, enrolled in the PEACH study in 2016-2018. METHODS: We modelled cardiac output, systemic vascular resistance and stroke volume as a function of gestational age using multilevel linear models with fractional polynomials. MAIN OUTCOME MEASURES: Unconditional and conditional reference ranges for cardiovascular parameters measured in gestational weeks 28-40. RESULTS: Our study cohort included 405 healthy pregnant women who contributed 1210 cardiovascular function measurements for analysis. Maximum cardiac output and stroke volume values were measured in gestational weeks 30-32 and decreased over the third trimester, whereas systemic vascular resistance increased during the same period. We created reference ranges for eight combinations of maternal height, age and parity. We also created a simple calculator to allow for implementation of the reference ranges in clinical practice. CONCLUSIONS: Our reference ranges allow the use of a bedside ultrasound device to non-invasively assess cardiac function in pregnancy and identify women at risk of complications. The unconditional ranges allow clinicians to evaluate isolated measurements and identify women needing follow-up. The conditional ranges incorporate information from previous measurements and improve monitoring over time.


Assuntos
Gestantes , Feminino , Gravidez , Humanos , Terceiro Trimestre da Gravidez , Estudos de Coortes , Estudos Prospectivos , Valores de Referência , Débito Cardíaco
15.
Cardiology ; 149(2): 183-188, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37827127

RESUMO

BACKGROUND: Although assessment of cardiovascular hemodynamics during exercise can provide clinical insights, it is challenging to acquire it in clinical settings. OBJECTIVES: Accordingly, this preliminary study was to determine whether a novel elaboration on systolic time interval measures (eSTICO) method of quantifying cardiac output and stroke volume was comparable to those obtained using a validated soluble gas (open circuit CO measure [OpCircCO]) method or calculation based on oxygen consumption (oxygen consumption-based CO [VO2CO]) during exercise. METHODS: For the present study, 14 healthy subjects (male: n = 12, female: n = 2) performed incremental exercise on a recumbent cycle ergometer. At rest and during exercise, cardiac output (CO) was obtained via the eSTICO method, while the OpenCircCO and VO2CO measures were obtained at the last minute of each workload. RESULTS: At peak, there was no difference between eSTICO and OpCircCO (12.39 ± 3.06 vs. 13.96 ± 2.47 L/min, p > 0.05), while there was a slight difference between eSTICO and VO2CO (12.39 ± 3.06 vs. 14.28 ± 2.55 L/min, p < 0.05). When we performed correlation analysis with all subjects and all measures of CO at all WL, between eSTICO and OpenCircCO, there was a good relationship (r = 0.707, p < 0.001) with a Bland and Altman agreement analysis demonstrating a -1.6 difference (95% LoA: -6.3-3.5). Between eSTICO and VO2CO, we observed an r = 0.865 (p < 0.001) and a Bland and Altman agreement analysis with a -1.2 difference (95% LoA: -4.8-2.4). CONCLUSION: A novel exploitation of cardiac hemodynamics using systolic timing intervals may allow a relatively good assessment of CO during exercise in healthy adults.


Assuntos
Teste de Esforço , Adulto , Humanos , Masculino , Feminino , Sístole , Estudos de Viabilidade , Débito Cardíaco , Volume Sistólico
16.
Ultrasound Obstet Gynecol ; 63(2): 198-205, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37325858

RESUMO

OBJECTIVE: Maternal cardiac function plays a crucial role in placental function and development. The maternal hemodynamic changes in twin pregnancy are more pronounced than those in singleton pregnancy, presumably due to a greater plasma volume expansion. In view of the correlation between maternal cardiac and placental function, it is plausible that chorionicity could influence maternal cardiac function. The aim of this study was to compare the longitudinal maternal hemodynamic changes between uncomplicated dichorionic (DC) and monochorionic (MC) twin pregnancies and in comparison to singleton pregnancies. METHODS: Included in the study were 40 MC diamniotic and 35 DC diamniotic uncomplicated twin pregnancies. These were compared with a group of 294 healthy singleton pregnancies from a previous cross-sectional study. All participants underwent a hemodynamic evaluation using an Ultrasound Cardiac Output Monitor (USCOM®), at three different stages in pregnancy (11-15 weeks, 20-24 weeks and 29-33 weeks). The following parameters were recorded: mean arterial pressure (MAP), stroke volume (SV), stroke volume index (SVI), heart rate, cardiac output (CO), cardiac index (CI), systemic vascular resistance (SVR), systemic vascular resistance index (SVRI), stroke volume variation, Smith-Madigan inotropy index (INO) and potential-to-kinetic-energy ratio (PKR). RESULTS: In the first trimester, DC and MC twin pregnancies showed lower MAP, SVR and PKR and higher CO and SV in comparison to singleton pregnancy. In the second trimester, maternal CO (8.33 vs 7.30 L/min, P = 0.03) and CI (4.52 vs 4.00 L/min/m2 , P = 0.02) were significantly higher in MC compared with DC twin pregnancy. In the third trimester, compared with in singleton pregnancy, women with MC twin pregnancy showed significantly higher PKR (24.06 vs 20.13, P = 0.03) and SVRI (1837.20 vs 1698.48 dynes × s/cm5 /m2 , P = 0.03), and significantly lower SV (78.80 vs 88.80 mL, P = 0.01), SVI (42.79 vs 50.31 mL/m2 , P < 0.01) and INO (1.70 vs 1.87 W/m2 , P = 0.03); these differences were not observed between DC twin and singleton pregnancies. CONCLUSIONS: Maternal cardiovascular function undergoes significant change during uncomplicated twin pregnancy and chorionicity influences maternal hemodynamics. In both MC and DC twin pregnancy, hemodynamic changes are detectable as early as the first trimester, showing higher maternal CO and lower SVR compared with singleton pregnancy. In DC twin pregnancy, the maternal hemodynamics remain stable during the rest of pregnancy. In contrast, in MC twin pregnancy, the rise in maternal CO continues in the second trimester in order to sustain the greater placental growth. There is a subsequent crossover, with a reduction in cardiovascular performance during the third trimester. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Placenta , Gravidez de Gêmeos , Gravidez , Feminino , Humanos , Gravidez de Gêmeos/fisiologia , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Gêmeos Dizigóticos
17.
J Intensive Care Med ; 39(4): 341-348, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37769347

RESUMO

PURPOSE: Bedside transthoracic echocardiography (TTEcho) is a noninvasive cardiac output (CO) monitoring method that has grown recently. However, there are questions regarding its accuracy compared to invasive methods. We aimed to evaluate the agreement and correlation of TTEcho and pulse index continuous CO (PiCCO) monitor measurements for CO and systolic volume (SV) in critically ill patients. METHODS: This prospective experimental study included consecutive adult patients who required invasive hemodynamic monitoring admitted at an intensive care unit in the Federal District, Brazil, from January/2019 to January/2021. Correlation and agreement between SV and CO measurements by PiCCO and TTEcho were performed using the Spearman correlation and the Bland-Altman analysis. RESULTS: The study enrolled 29 patients, with adequate TTEcho evaluations in all patients. There were very strong correlations between CO-TTEcho and CO-PiCCO (r = 0.845, P < .001) and SV-TTEcho and SV-PiCCO (r = 0.800, P < .001). TTEcho estimations for CO and SV were feasible within the limits of agreement in 96.6% (28/29) compared to PiCCO. The mean difference between CO-PiCCO and CO-TTEcho was 0.250 L/min (limits of agreement: -1.083 to 1.583 L/min, percentage error: 21.0%), and between SV-PiCCO and SV-TTEcho was 2.000 mL (limits of agreement: -16.960 to 20.960, percentage error: 24.3%). The reduced cardiac index (CI) measurements by TTEcho showed an accuracy of 89.7% (95% IC: 72.6%-97.8%) and an F1 score of 92.7% (95% IC: 75.0%-98.0%), considering the CI-PiCCO as the gold standard. CONCLUSION: Echocardiographic measurements of CO and SV are comparable to measurements by PiCCO. These results reinforce echocardiography as a reliable tool to evaluate hemodynamics in critically ill patients.


Assuntos
Estado Terminal , Ecocardiografia , Adulto , Humanos , Volume Sistólico , Estudos Prospectivos , Débito Cardíaco , Monitorização Fisiológica/métodos
18.
J Intensive Care Med ; 39(7): 628-635, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38190576

RESUMO

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.


Assuntos
Artérias Carótidas , Hidratação , Veias Jugulares , Ultrassonografia Doppler , Humanos , Projetos Piloto , Masculino , Feminino , Hidratação/métodos , Pessoa de Meia-Idade , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos , Artérias Carótidas/diagnóstico por imagem , Idoso , Ressuscitação/métodos , Pressão Venosa Central/fisiologia , Estudos Retrospectivos , Adulto , Volume Sistólico/fisiologia , Débito Cardíaco/fisiologia , Serviço Hospitalar de Emergência , Hemodinâmica
19.
Eur J Pediatr ; 183(5): 2183-2192, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376594

RESUMO

We aimed to establish reference ranges for USCOM parameters in preterm infants, determine factors that affect cardiac output, and evaluate the measurement repeatability. This retro-prospective study was performed at Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. We included infants below 32 weeks of gestational age (GA) and/or 1500 g of birth weight (BW). We excluded infants with congenital heart diseases or hemodynamic instability. Measurements were performed at 3 ± 1, 7 ± 2, and 14 ± 2 postnatal days. We analyzed 204 measurements from 92 patients (median GA = 30.57 weeks, BW = 1360 g). The mean (SD) cardiac output (CO) was 278 (55) ml/min/kg, cardiac index (CI) was 3.1 (0.5) L/min/m2, and systemic vascular resistance (SVRI) was 1292 (294) d*s*cm-5/m2. CO presented a negative correlation with postmenstrual age (PMA), while SVRI presented a positive correlation with PMA. The repeatability coefficient was 31 ml/kg/min (12%).  Conclusion: This is the first study describing reference values for USCOM parameters in hemodynamically stable preterm infants and factors affecting their variability. Further studies to investigate the usefulness of USCOM for the longitudinal assessment of patients at risk for cardiovascular instability or monitoring the response to therapies are warranted. What is Known: • The ultrasonic cardiac output monitoring (USCOM) has been widely used on adult and pediatric patients and reference ranges for cardiac output (CO) by USCOM have been established in term infants. What is New: • We established reference values for USCOM parameters in very preterm and very-low-birth-weight infants; the reference ranges for CO by USCOM in the study population were 198-405 ml/kg/min. • CO normalized by body weight presented a significant negative correlation with postmenstrual age (PMA); systemic vascular resistance index presented a significant positive correlation with PMA.


Assuntos
Débito Cardíaco , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Débito Cardíaco/fisiologia , Masculino , Feminino , Valores de Referência , Estudos Prospectivos , Estudos Retrospectivos , Hemodinâmica/fisiologia , Reprodutibilidade dos Testes , Idade Gestacional , Monitorização Fisiológica/métodos , Resistência Vascular/fisiologia
20.
Eur J Pediatr ; 183(4): 1849-1855, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38276999

RESUMO

Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy.     Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes.      Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: •  In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.


Assuntos
Choque Séptico , Recém-Nascido , Humanos , Choque Séptico/diagnóstico por imagem , Choque Séptico/terapia , Ecocardiografia , Hemodinâmica , Débito Cardíaco/fisiologia , Ventrículos do Coração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA