Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.696
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Biol Chem ; 300(3): 105735, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336298

RESUMO

One of the independent risk factors for atrial fibrillation is diabetes mellitus (DM); however, the underlying mechanisms causing atrial fibrillation in DM are unknown. The underlying mechanism of Atrogin-1-mediated SK2 degradation and associated signaling pathways are unclear. The aim of this study was to elucidate the relationship among reactive oxygen species (ROS), the NF-κB signaling pathway, and Atrogin-1 protein expression in the atrial myocardia of DM mice. We found that SK2 expression was downregulated comitant with increased ROS generation and enhanced NF-κB signaling activation in the atrial cardiomyocytes of DM mice. These observations were mimicked by exogenously applicating H2O2 and by high glucose culture conditions in HL-1 cells. Inhibition of ROS production by diphenyleneiodonium chloride or silencing of NF-κB by siRNA decreased the protein expression of NF-κB and Atrogin-1 and increased that of SK2 in HL-1 cells with high glucose culture. Moreover, chromatin immunoprecipitation assay demonstrated that NF-κB/p65 directly binds to the promoter of the FBXO32 gene (encoding Atrogin-1), regulating the FBXO32 transcription. Finally, we evaluated the therapeutic effects of curcumin, known as a NF-κB inhibitor, on Atrogin-1 and SK2 expression in DM mice and confirmed that oral administration of curcumin for 4 weeks significantly suppressed Atrogin-1 expression and protected SK2 expression against hyperglycemia. In summary, the results from this study indicated that the ROS/NF-κB signaling pathway participates in Atrogin-1-mediated SK2 regulation in the atria of streptozotocin-induced DM mice.


Assuntos
Diabetes Mellitus Experimental , Átrios do Coração , Proteínas Musculares , NF-kappa B , Espécies Reativas de Oxigênio , Proteínas Ligases SKP Culina F-Box , Transdução de Sinais , Canais de Potássio Ativados por Cálcio de Condutância Baixa , Animais , Camundongos , Fibrilação Atrial/etiologia , Fibrilação Atrial/genética , Fibrilação Atrial/metabolismo , Fibrilação Atrial/fisiopatologia , Linhagem Celular , Imunoprecipitação da Cromatina , Curcumina/farmacologia , Curcumina/uso terapêutico , Diabetes Mellitus Experimental/induzido quimicamente , Diabetes Mellitus Experimental/complicações , Diabetes Mellitus Experimental/tratamento farmacológico , Regulação da Expressão Gênica/efeitos dos fármacos , Glucose/farmacologia , Átrios do Coração/metabolismo , Átrios do Coração/fisiopatologia , Peróxido de Hidrogênio/farmacologia , Hiperglicemia/genética , Hiperglicemia/metabolismo , Proteínas Musculares/genética , Proteínas Musculares/metabolismo , Miocárdio , Miócitos Cardíacos , NF-kappa B/antagonistas & inibidores , NF-kappa B/metabolismo , Proteólise , Espécies Reativas de Oxigênio/metabolismo , RNA Interferente Pequeno , Proteínas Ligases SKP Culina F-Box/genética , Proteínas Ligases SKP Culina F-Box/metabolismo , Canais de Potássio Ativados por Cálcio de Condutância Baixa/genética , Canais de Potássio Ativados por Cálcio de Condutância Baixa/metabolismo
2.
Am Heart J ; 273: 61-71, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38685463

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in patients with heart failure (HF) and is associated with worse clinical outcomes. We evaluated the relationship between AF and longitudinal changes in health-related quality of life (HRQoL) measured by Kansas City Cardiomyopathy Questionnaire (KCCQ) in both HF with preserved (HFpEF) and reduced ejection fraction (HFrEF). METHODS: This is a post-hoc analysis of the TOPCAT and HF-ACTION trials. The effect of AF on KCCQ overall summary scores (OSS), in both trials, was examined using a mixed effects regression model. Patients were divided into 3 groups according to AF status at baseline: patients with a history of AF but no AF detected on ECG at enrollment (Hx AF group), patients with history of AF and AF detected on ECG at enrollment (ECG AF group) and patients with post-randomization new-onset AF (New AF group). RESULTS: In TOPCAT, among 1,710 patients with KCCQ data available, AF was associated with a significantly lower KCCQ-OSS (-3.98; 95% CI -7.21: -0.74) at 48 months, with a significant AF status by time interaction (P = .03). In HF-ACTION, among 1,814 patients with available KCCQ data, AF was associated with a significantly lower KCCQ-OSS (-3.67; 95% CI -6.21: -1.41) at 24 months but there was no significant AF status by time interaction. In both trials, the type of AF was not associated with significant changes in KCCQ-OSS score. CONCLUSION: Ιn patients with both HFpEF and HFrEF, AF was independently associated with worse HRQoL measured by KCCQ.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Volume Sistólico , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/complicações , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/complicações , Volume Sistólico/fisiologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Eletrocardiografia , Inquéritos e Questionários
3.
J Cardiovasc Electrophysiol ; 35(6): 1121-1128, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38536760

RESUMO

INTRODUCTION: Postoperative atrial fibrillation (POAF) is common following open heart surgery, and is associated with significant morbidity. Medications used for ventricular rate control of POAF may not be effective in controlling rapid ventricular rates during the postoperative period because of increased sympathetic tone. The purpose of this study was to develop nonpharmacologic rate control of POAF by atrioventricular node (AVN) fat pad stimulation using clinically available temporary pacing wires in the canine sterile pericarditis model. METHODS: We studied 10 sterile pericarditis dogs in the closed-chest state on postoperative days 1-3. The AVN fat pad stimulation (amplitude 2-15 mA; frequency 20 Hz; pulse width 0.03-0.2 ms) was performed during sustained POAF (>5 min). We measured ventricular rate and inefficient ventricular contractions during sustained POAF and compared it with and without AVN fat pad stimulation. Also, the parameters of AVN fat pad stimulation to achieve a rate control of POAF were measured over the postoperative days. RESULTS: Eleven episodes of sustained POAF were induced in 5/10 sterile pericarditis dogs in the closed-chest state on postoperative days 1-2. During POAF, the AVN fat pad stimulation decreased the ventricular rate from 178 ± 52 bpm to 100 ± 8 bpm in nine episodes. Nonpharmacologic rate control therapy successfully controlled the ventricular rate and eliminated inefficient ventricular contractions during POAF for the duration of the AVN fat pad stimulation. The AVN fat pad stimulation output remained relatively stable over the postoperative days. CONCLUSION: During sustained POAF, nonpharmacologic rate control by AVN fat pad stimulation effectively and safely controlled rapid ventricular rates throughout the postoperative period.


Assuntos
Fibrilação Atrial , Modelos Animais de Doenças , Frequência Cardíaca , Pericardite , Animais , Cães , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Pericardite/fisiopatologia , Pericardite/diagnóstico , Estimulação Cardíaca Artificial , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Masculino , Fatores de Tempo , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Tecido Adiposo/fisiopatologia , Complicações Pós-Operatórias/etiologia
4.
J Cardiovasc Electrophysiol ; 35(5): 975-983, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38482937

RESUMO

INTRODUCTION: Lesion size index (LSI) was introduced with the use of Tacticath™ and as a surrogate of lesion quality. The metric used to achieve the predetermined values involves combined information of contact force (CF), power and radiofrequency time. Rapid atrial pacing (RAP) and high-frequency low-tidal volume ventilation (HFLTV) independently or in combination improve catheter stability and CF and quality of lesions. Data of the impact of body weight adjusted HFLTV ventilation strategy associated with RAP in the lesion metrics still lacking. The study aimed to compare the results of high-power short-duration (HPSD) atrial fibrillation ablation using simultaneous weight adjusted HFLTV and RAP and standard ventilation (SV) protocol. METHODS: Prospective, nonrandomized study with 136 patients undergoing de novo ablation divided into two groups; 70 in RAP (100 ppm) + HFLTV with 4 mL/kg of tidal volume and 25 breaths/min (group A) and 66 patients with SV in intrinsic sinus rhythm (group B). Ablation using 50 W, CF of 5-10 g/10-20 g and 40 mL/minute flow rate on the posterior and anterior left atrial wall, respectively. RESULTS: No procedure-related complications. Group A: Mean LSI points 70 ± 16.5, mean total lower LSI 3.4 ± 0.5, mean total higher LSI 8.2 ± 0.4 and mean total LSI 5.6 ± 0.6. Anterior and posterior wall mean total LSI was 6.0 ± 0.4 and 4.2 ± 0.3, respectively. Mean local impedance drop (LID) points were 118.8 ± 28.4, mean LID index (%) 12.9 ± 1.5, and mean LID < 12% points 55.9 ± 23.8. Anterior and posterior wall mean total LID index were 13.6 ± 2.0 and 11.9 ± 1.7, respectively. Recurrence in 11 (15.7%) patients. Group B: Mean LSI points 56 ± 2.7, mean total lower LSI 2.9 ± 0.7, mean total higher LSI 6.9 ± 0.9, and mean total LSI 4.8 ± 0.8. Anterior and posterior wall mean total LSI was 5.1 ± 0.3 and 3.5 ± 0.5, respectively. Mean LID points were 111.4 ± 21.5, mean LID index (%) 11.4 ± 1.2, and mean LID < 12% points 54.9 ± 25.2. Anterior and posterior wall mean total LID index were 11.8 ± 1.9 and 10.3 ± 1.7, respectively. Recurrence in 14 (21.2%) patients. Mean follow up was 15.2 ± 4.4 months. CONCLUSION: Weight adjusted HFLTV ventilation with RAP HPSD ablation produced lower recurrence rate and better LSI and LID parameters in comparison to SV and intrinsic sinus rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Volume de Ventilação Pulmonar , Humanos , Feminino , Projetos Piloto , Masculino , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Frequência Cardíaca , Estimulação Cardíaca Artificial , Peso Corporal
5.
J Cardiovasc Electrophysiol ; 35(5): 984-993, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38486082

RESUMO

INTRODUCTION: Little is known about very early atrial fibrillation (AF) ablation after first AF detection. METHODS: We evaluated patients with AF ablation <4 months from newly diagnosed paroxysmal AF (NEWPaAF) and newly diagnosed persistent AF (NEWPeAF). We compared the two patient populations and compared ablation outcomes to those undergoing later ablation. RESULTS: Ablation was done <4 months from AF diagnosis in 353 patients (135 = paroxysmal, 218 = persistent). Early ablation outcome was best for NEWPaAF versus NEWPeAF for initial (p = 0.030) but not final (p = 0.102) ablation. Despite recent AF diagnosis in both groups, they were clinically quite different. NEWPaAF patients were younger (64.3 ± 13.0 vs. 67.3 ± 10.9, p = 0.0020), failed fewer drugs (0.39 vs. 0.60, p = 0.007), had smaller LA size (4.12 ± 0.58 vs. 4.48 ± 0.59 cm, p < 0.0001), lower BMI (28.8 ± 5.0 vs. 30.3 ± 6.0, p = 0.016), and less CAD (3.7% vs. 11.5%, p = 0.007), cardiomyopathies (2.2% vs. 22.9%, p = 0.0001), hypertension (46.7% vs. 67.4%, p < 0.0001), diabetes (8.1% vs. 17.4%, p = 0.011) and sleep apnea (20.0% vs. 30.3%, p = 0.031). For NEWPaAF, early ablation AF-free outcome was no better than later ablation (p = 0.314). For NEWPeAF, AF-free outcomes were better for early ablation than later ablation (p < 0.0001). Delaying ablation allowed more strokes/TIAs in both AF types (paroxysmal p = 0.014, persistent p < 0.0001). CONCLUSIONS: Patients presenting for early ablation after newly diagnosed persistent AF have more pre-existing comorbidities and worse initial ablation outcomes than patients with NEWPaAF. For NEWPaAF, there was no advantage to early ablation, as long as the AF remained paroxysmal. For NEWPeAF, early ablation gave better outcomes than later ablation and they should undergo early ablation. For both AF types, waiting was associated with more neurologic events, suggesting all patients should consider earlier ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Masculino , Ablação por Cateter/efeitos adversos , Feminino , Pessoa de Meia-Idade , Fatores de Tempo , Idoso , Fatores de Risco , Resultado do Tratamento , Frequência Cardíaca , Tempo para o Tratamento , Potenciais de Ação , Estudos Retrospectivos
6.
J Cardiovasc Electrophysiol ; 35(6): 1095-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38511484

RESUMO

INTRODUCTION: In cryoballoon ablation (CBA) procedures, transseptal access (TSA) is generally achieved using a standard sheath and needle system that is exchanged for the cryoballoon delivery sheath and dilator over a long wire. Sheath exchange has been related with air embolic events. Recently, an integrated dilator-needle system assembled to the cryoballoon sheath was introduced. We aimed to evaluate the efficacy and safety of an integrated TSA tool compared with the traditional approach in atrial fibrillation CBA procedures. METHODS: Patients scheduled for CBA procedures were randomized 1:1 to traditional TSA (t-TSA) or integrated TSA (i-TSA). TSA time was defined as time from superior vena cava to LA insertion of the cryoballoon delivery sheath, after sheath exchange (t-TSA) or directly (i-TSA). RESULTS: Ninety-seven patients (76 males, mean age 59 ± 10 years) were randomized, 48 patients underwent t-TSA, and 49 i-TSA. Mean TSA time was 5 min 59 s ± 5 min 36 s in the t-TSA group and 2 min 59 s ± 2 min 14 s in the i-TSA group (p < .001). Total fluoroscopy time, skin-to-skin procedure time, and LA dwell time were respectively 15 ± 6, 69 ± 16, and 44 ± 12 min in the t-TSA group and 13 ± 6, 65 ± 15, and 43 ± 11 min in the i-TSA group (p = ns). No clinically significant acute complications related to TSA were noted in both cohorts. CONCLUSION: This is the first randomized study comparing both TSA approaches. TSA in CBA procedures using this integrated tool enables a safe and efficient workflow, reducing TSA time and avoiding sheath exchange.


Assuntos
Fibrilação Atrial , Criocirurgia , Desenho de Equipamento , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Cateteres Cardíacos , Duração da Cirurgia , Agulhas , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Estudos Prospectivos , Frequência Cardíaca , Potenciais de Ação
7.
J Cardiovasc Electrophysiol ; 35(6): 1150-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38566579

RESUMO

INTRODUCTION: Proactive esophageal cooling has been FDA cleared to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures. Data suggest that procedure times for RF pulmonary vein isolation (PVI) also decrease when proactive esophageal cooling is employed instead of luminal esophageal temperature (LET) monitoring. Reduced procedure times may allow increased electrophysiology (EP) lab throughput. We aimed to quantify the change in EP lab throughput of PVI cases after the introduction of proactive esophageal cooling. METHODS: EP lab throughput data were obtained from three EP groups. We then compared EP lab throughput over equal time frames at each site before (pre-adoption) and after (post-adoption) the adoption of proactive esophageal cooling. RESULTS: Over the time frame of the study, a total of 2498 PVIs were performed over a combined 74 months, with cooling adopted in September 2021, November 2021, and March 2022 at each respective site. In the pre-adoption time frame, 1026 PVIs were performed using a combination of LET monitoring with the addition of esophageal deviation when deemed necessary by the operator. In the post-adoption time frame, 1472 PVIs were performed using exclusively proactive esophageal cooling, representing a mean 43% increase in throughput (p < .0001), despite the loss of two operators during the post-adoption time frame. CONCLUSION: Adoption of proactive esophageal cooling during PVI ablation procedures is associated with a significant increase in EP lab throughput, even after a reduction in total number of operating physicians in the post-adoption group.


Assuntos
Ablação por Cateter , Esôfago , Veias Pulmonares , Humanos , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Resultado do Tratamento , Hipotermia Induzida , Fatores de Risco , Duração da Cirurgia , Técnicas Eletrofisiológicas Cardíacas , Fluxo de Trabalho , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino
8.
J Cardiovasc Electrophysiol ; 35(6): 1061-1068, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38501564

RESUMO

INTRODUCTION: The relationships between baseline tissue local impedance (LI), contact force (CF), atrial fibrosis, and atrial rhythm are uninvestigated in a clinical setting. We compared the relationship of LI and CF between atrial fibrillation (AF) and sinus rhythm (SR) accounting for the effects of atrial fibrosis as assessed by bipolar voltage and LI. METHODS: Patients undergoing persistent AF ablation were recruited. LI was recorded referenced to patient blood pool (LIr) and concurrent to changes in CF, with data collected at the same locations in AF and SR. RESULTS: Twenty patients were recruited. 109 locations were sampled obtaining 1903 data points (SR: 966, AF: 937). CF correlated strongly with LI (repeated measures correlation = 0.64). The relationship between CF and LIr was logarithmic. Rhythm and CF had a significant main (both p < .0005) and interaction effect (p = .022) on tissue LI: AF demonstrated higher LIr values than SR for similar CF. Bipolar voltage had no effect on the relationship of CF to LIr in either rhythm. Assessing fibrosis using LIr showed an interaction effect with CF for LIr in SR and AF, (SR: p < .0005, AF: p = .01), with increased fibrosis showing lesser change in LIr per gram of CF. CONCLUSIONS: CF and rhythm significantly affect the measured LIr of LA myocardium. Optimal catheter-tissue coupling may be better achieved with higher levels of CF and in AF rather than SR. Atrial fibrosis, as assessed by LIr but not bipolar voltage, affected the CF-LI relationship.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Função do Átrio Esquerdo , Ablação por Cateter , Fibrose , Átrios do Coração , Frequência Cardíaca , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Átrios do Coração/fisiopatologia , Idoso , Fatores de Tempo , Técnicas Eletrofisiológicas Cardíacas , Impedância Elétrica , Valor Preditivo dos Testes , Resultado do Tratamento , Remodelamento Atrial
9.
J Cardiovasc Electrophysiol ; 35(6): 1165-1173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38571287

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is often performed under general anaesthesia (GA) or deep sedation. Anaesthetic availability is limited in many centers, and deep sedation is prohibited in some countries without anaesthetic support. Very high-power short duration (vHPSD-90W/4 s) PVI using the Q-Dot catheter is generally well tolerated under mild conscious sedation (MCS) though an understanding of catheter stability and long-term effectiveness is lacking. We analyzed lesion metrics and 12-month freedom from atrial arrythmia with this approach. METHODS: Our approach to radiofrequency (RF) PVI under MCS is standardized and includes a single catheter approach with a steerable sheath. We identified patients undergoing Q-Dot RF PVI between March 2021 and December 2022 in our center, comparing those undergoing vHPSD ablation under MCS (90W/MCS) against those undergoing 50 W ablation under GA (50 W/GA) up to 12 months of follow-up. Data were extracted from clinical records and the CARTO system. RESULTS: Eighty-three patients met our inclusion criteria (51 90W/MCS; 32 50 W/GA). Despite shorter ablation times (353 vs. 886 s; p < .001), the 90 W/MCS group received more lesions (median 87 vs. 58, p < .001), resulting in similar procedure times (149.3 vs. 149.1 min; p = .981). PVI was achieved in all cases, and first pass isolation rates were similar (left wide antral circumferential ablation [WACA] 82.4% vs. 87.5%, p = .758; right WACA 74.5% vs. 78.1%, p = .796; 90 W/MCS vs. 50 W/GA respectively). Analysis of 6647 ablation lesions found similar mean impedance drops (10.0 ± 1.9 Ω vs. 10.0 ± 2.2 Ω; p = .989) and mean contact force (14.6 ± 2.0 g vs. 15.1 ± 1.6 g; p = .248). Only median 2.5% of lesions in the 90 W/MCS cohort failed to achieve ≥ 5 Ω drop. In the 90 W/MCS group, there were no procedural related complications, and 12-month freedom from atrial arrhythmia was observed in 78.4%. CONCLUSION: vHPSD PVI is feasible under MCS, with encouraging acute and long-term procedural outcomes. This provides a compelling option for centers with limited anaesthetic support.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Sedação Consciente , Frequência Cardíaca , Veias Pulmonares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fatores de Tempo , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Cateteres Cardíacos , Intervalo Livre de Progressão , Fatores de Risco
10.
J Cardiovasc Electrophysiol ; 35(5): 1007-1016, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468346

RESUMO

INTRODUCTION: Cather ablation (CA) is a well-recognized treatment alternative for atrial fibrillation (AF) patients despite more than 20% ablation-treated patients suffering from AF recurrence. The underlying mechanism of AF recurrence postablation is probably associated with high cardiac parasympathetic activity, which can be assessed with deceleration capacity (DC) of heart rate. Given that the relationship between DC and AF recurrence is still controversial, this systematic review and meta-analysis was performed to investigate the characteristics of DC in patients with and without AF recurrence, evaluating the prognostic value of DC in AF patients after CA. METHODS: A literature search was systematically performed in the Embase, PubMed, Web of Science, China National Knowledge Infrastructure (CNKI), and Wanfang databases until October 01, 2023. The observational studies reporting either the pre- and postablation DC in both recurrence and non-recurrence groups or the ratios based on DC for predicting AF recurrence were mainly included. Weighted mean differences (WMD) or odds ratios (OR) based on DC would be calculated with a random-effect model, if heterogeneity estimated with the I2 index and Q statistic was significant (I2 > 50% or p < .05); otherwise, a fixed-effect model would be utilized. RESULTS: A total of eight observational studies involving 914 AF patients treated with radiofrequency or cryoballoon ablation were included in this study. Ablation-treated patients with AF recurrence had the higher DC postablation in relation to those without recurrence (WMD, 1.00; 95% confidence interval [CI], 0.33-1.67; p < .01), which was present up to 3 months of follow-up (WMD, 1.54; 95% CI, 1.11-1.96; p < .01), whereas there was no statistical significance in DC before ablation between recurrence and non-recurrence groups (WMD, 0.34; 95% CI, -0.12 to 0.79; p = .15). The high DC postablation was a risk factor for AF recurrence in ablation-treated patients (OR, 2.17; 95% CI, 1.44-3.25; p < .01). CONCLUSION: The high DC postablation was associated with the risk of AF recurrence, suggesting that DC may act as a prognostic indicator in AF patients treated with CA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Desaceleração , Frequência Cardíaca , Valor Preditivo dos Testes , Recidiva , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 35(5): 886-894, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38433316

RESUMO

INTRODUCTION: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using power-controlled ablation catheters with conventional power ranges was the norm. There has been increased adoption of a high-power and very high-power short-duration ablation practice propelled by the availability of the temperature-controlled radiofrequency QDOT MICRO catheter. METHODS: There are fundamental differences in biophysics between very high-powered temperature guided ablation and conventional ablation strategy that may impact patient outcomes. The catheter's design and ablation modes offer flexibility in technique while accommodating the individual operator's clinical discretion and preference to deliver a durable, transmural, and contiguous lesion set. RESULTS: Here, we provide recommendations for 3 different workflows using the QDOT MICRO catheter in a step-by-step manner for pulmonary vein isolation based on our cumulative experience as early adopters of the technology and the data available in the scientific literature. CONCLUSIONS: With standardization, temperature-controlled ablation with the QDOT MICRO catheter provides operators the flexibility of implementing different ablation strategies to ensure durable contiguous pulmonary vein isolation depending on patient characteristics.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Desenho de Equipamento , Veias Pulmonares , Humanos , Potenciais de Ação , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/instrumentação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Temperatura , Fatores de Tempo , Resultado do Tratamento , Fluxo de Trabalho
12.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de Progressão
13.
J Cardiovasc Electrophysiol ; 35(6): 1140-1149, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38561951

RESUMO

INTRODUCTION: The presence of low-voltage zones (LVZs) in the left atrium (LA) is associated with the recurrence of atrial fibrillation (AF) following pulmonary vein isolation (PVI). However, there is variability and conflict in the data regarding predictors of LVZs as reported in previous studies. The objective of this study was to identify predictors for the presence of LVZs in a cohort of patients with persistent AF. METHODS: The study prospectively enrolled 439 patients with persistent AF who were scheduled for ablation. Voltage map of the LA was collected using a multipolar catheter. An LVZ was defined as an area of ≥3 cm2 exhibiting a peak-to-peak bipolar voltage of <0.5 mV. RESULTS: The mean age of the cohort was 65.3 ± 8.6 years and 26.4% were female. Additionally, 25.7% had significant LVZs, most frequently located in the anterior wall of the LA. Multivariable analysis identified the following independent predictors for LVZ: advanced age (OR [odds ratio] = 1.08, 95% CI [confidence interval] = 1.03-1.13, p = .002); female sex (OR = 4.83, 95% CI = 2.66-8.76, p < .001); coronary artery disease (CAD) (OR = 3.20, 95% CI = 1.32-7.77, p = .01) and enlarged LA diameter (OR = 1.10, 95% CI = 1.04-1.17, p = .001). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve for the final model was 0.829. CONCLUSION: Approximately 25% of the patients with persistent AF had LVZs. Advanced age, female sex, CAD, and a larger LA were independent predictors for LVZs with the model demonstrating a very good AUC for the ROC curve. These findings hold the potential to be used to tailor the ablation procedure for the individual patient.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Valor Preditivo dos Testes , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Medição de Risco , Fatores Sexuais , Fatores de Tempo , Fatores Etários
14.
J Cardiovasc Electrophysiol ; 35(6): 1078-1082, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38509774

RESUMO

INTRODUCTION: Percutaneous left atrial appendage occlusion (LAAO) is traditionally performed under general anesthesia with trans-esophageal echocardiography guidance. Intracardiac echo (ICE)-guided LAAO closure is increasing in clinical use. The ICE catheter is crossed into LA via interatrial septum (IAS) after the septum is dilated with LAAO delivery sheath. This step can be time-consuming and requires significant ICE catheter manipulation, which increases the risk of cardiac perforation. Pre-emptive septal balloon dilation can potentially help with ICE advancement in the LA. We sought to evaluate the effect of pre-dilation of the IAS with an 8 mm balloon on the ease of crossing the ICE catheter, fluoroscopy time for crossing, and overall procedure time. METHODS: The Piedmont LAAO registry was used to identify consecutive patients who underwent LAAO. The initial 25 patients in whom balloon dilation of the IAS was performed served as the experimental cohort, and the 25 consecutive patients before that in whom balloon dilation was not performed served as controls. In the experimental group, after a trans-septal puncture, the sheath was retracted to the right atrium with a guidewire still in the LA. An 8 × 40 mm Evercoss™ over the wire balloon was inflated across the IAS. The ICE catheter was then crossed into the LA using the fluoroscopic landmark of the guide wire and the ICE imaging. The sheath was then advanced along the ICE catheter via the transseptal puncture (TSP) and the procedure continued. Follow-up compputed tomography imaging was obtained at 4-8 weeks. RESULTS: Each group consisted of 25 patients. There were no significant differences in baseline characteristics. All procedures were performed successfully under conscious sedation and ICE guidance. There was a significant reduction in the overall procedure time, fluoroscopy time, and time for transseptal puncture to ICE in LA. There was no difference in the size of the acute residual interatrial shunt, as measured via ICE, or the size and presence of iatrogenic ASD at follow-up. CONCLUSION: Balloon dilation of TSP is safe and is associated with increased efficiency in ICE-guided LAAO procedures.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Sistema de Registros , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ultrassonografia de Intervenção , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Septo Interatrial/diagnóstico por imagem , Valor Preditivo dos Testes
15.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38556747

RESUMO

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Assuntos
Fibrilação Atrial , Criocirurgia , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/instrumentação , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Átrios do Coração/cirurgia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Potenciais de Ação , Frequência Cardíaca , Fatores de Tempo , Estudos Retrospectivos , Recidiva , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia
16.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468182

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Vasos Coronários/diagnóstico por imagem , Oclusão do Apêndice Atrial Esquerdo , Desenho de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
17.
J Cardiovasc Electrophysiol ; 35(6): 1156-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38566599

RESUMO

INTRODUCTION: Left atrial (LA) low voltage areas (LVA) are a controversial target in atrial fibrillation ablation procedures. However, LVA and LA volume are good predictors of arrhythmia recurrence in ablation-naïve patients. Their predictive value in progressively diseased pre-ablated atria is uncertain. METHODS: Consecutive patients with recurrent atrial fibrillation (AF) or atrial tachycardia (AT), who were scheduled for repeat LA ablation, were enrolled in the prospective Bernau ablation registry between 2016 and 2020. All patients received a complete LA ultrahigh-density map before ablation. Maps were analyzed for LA size, LVA percentage and distribution. The predictive value of demographic, anatomic, and mapping variables on AF recurrence was analyzed. RESULTS: 160 patients (50.6% male, 1.3 pre-ablations, 60% persistent AF) with complete LA voltage maps were included. Mean follow-up time was 16 ± 11 months. Mean recorded electrograms (EGMs) per map were 9754 ± 5808, mean LA volume was 176.1 ± 35.9 ml and mean rate of LVAs <0.5 mV was 30.6% ± 23.1%. During follow-up recurrence rate of AF or AT >30 s was 55.6%. Patients with recurrence had a significant higher percentage of LVAs (40.0% vs. 18.8%, p < .001) but no relevant difference in LA volume (172 vs. 178 mL, p = .299). ROC curves revealed LVA as a good predictor for recurrence (AUC = 0.79, p < .001) and a cut-off of 22% LVAs with highest sensitivity (73.0%) and specificity (71.8%). Based on this cut off, event free survival was significantly higher in the Low LVA group (p < .01). CONCLUSION: Total LVA percentage has a good predictive power on arrhythmia recurrence in a cohort of advanced scarred left atria in repeat procedures independent of the applied ablation strategy. Left atrial volume seems to have minor impact on the rhythm outcome in our study cohort.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Função do Átrio Esquerdo , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Frequência Cardíaca , Valor Preditivo dos Testes , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Fatores de Risco , Fatores de Tempo , Estudos Prospectivos , Reoperação , Medição de Risco , Resultado do Tratamento , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Remodelamento Atrial
18.
J Cardiovasc Electrophysiol ; 35(6): 1203-1211, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38606650

RESUMO

INTRODUCTION: Heart failure patients with a history of atrial fibrillation (AF) and ventricular tachycardia/ventricular fibrillation (VT/VF) are known to have worse outcomes. However, there are limited data on the temporal relationship between development of these arrhythmias and the risk of subsequent congestive heart failure (CHF) exacerbation and death. METHODS: The study cohort comprised 5511 patients implanted with an implantable cardioverter-defibrillator (ICD) in landmark clinical trials (MADIT-II, MADIT-RISK, MADIT-CRT, MADIT-RIT, and RAID) who were in sinus rhythm at enrollment. Multivariate cox analysis was performed to evaluate the time-dependent association between development of in-trial device detected AF and VT/VF with subsequent CHF exacerbation and death. RESULTS: Multivariate analysis showed that AF occurrence and VT/VF occurrence were both associated with a similar magnitude of risk for subsequent CHF exacerbation (HR = 1.73 and 1.87 respectively, p < .001 for both). In contrast, only in-trial VT/VF was associated with a significant > two-fold increase in the risk of subsequent mortality (HR = 2.13, p < .001) whereas AF occurrence was not associated with a significant mortality increase after adjustment for in-trial VT/VF (HR = 1.36, p = .096). CONCLUSION: Our findings from a large cohort of ICD recipients enrolled in landmark clinical trials show that device detected AF and VT/VF can be used to identify patients with increased risk for CHF exacerbation and mortality. These findings suggest a need for early intervention in CHF patients who develop device-detected atrial and ventricular tachyarrhythmias.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Masculino , Feminino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Idoso , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fibrilação Atrial/mortalidade , Fatores de Risco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia , Fibrilação Ventricular/etiologia , Fatores de Tempo , Medição de Risco , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Resultado do Tratamento
19.
Microvasc Res ; 154: 104685, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38593952

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) is frequently observed in atrial fibrillation (AF), the most commonly sustained arrhythmia. Nevertheless, an in-depth prognostic significance of CMD in AF is lacking. We aimed to provide insight into the predictive impact of CMD assessed by a novel non-invasive coronary angiography-derived index of microcirculatory resistance (caIMR) for major adverse events (MACE) in AF patients. METHOD: This study included patients with AF who underwent invasive coronary angiography due to suspected cardiac ischemia and did not exhibit obstructive epicardial coronary artery disease (≤50 % stenosis). The caIMR was prospectively evaluated, and the optimal cutoff value for predicting MACE was determined through ROC analysis. RESULT: A total of 463 patients with AF were enrolled. During a median of 33 months of follow-up, 111 (23.97 %) patients had MACE endpoints. The best caIMR cutoff value was 39.28. In patients with MACE, both the mean caIMR and the prevalence of elevated caIMR (caIMR>39.28) were significantly higher compared to those without MACE. An elevated caIMR was linked to a higher risk of MACE (log-rank P < 0.001) and emerged as an independent predictor of clinical outcomes (HR: 4.029; 95 % CI: 2.529-6.418; P < 0.001). In addition, the risk of MACE was higher in high caIMR patients with non-paroxysmal AF (log-rank P < 0.001) and no catheter ablation (log-rank P < 0.001). CONCLUSION: Elevated caIMR is common and showed a vital independent prognostic significance in AF patients. In addition to well-known risk factors, assessment of microvascular function can be a feasible approach for early prevention and a therapeutic target in AF patients.


Assuntos
Fibrilação Atrial , Angiografia Coronária , Circulação Coronária , Vasos Coronários , Microcirculação , Valor Preditivo dos Testes , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Prognóstico , Medição de Risco , Fatores de Tempo , Estudos Prospectivos , Resistência Vascular , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/complicações
20.
Eur J Clin Invest ; 54(6): e14175, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38308431

RESUMO

BACKGROUND: There is no defined cause for cryptogenic stroke/embolic stroke of undetermined source (CS-ESUS). As atrial fibrillation (AF) develops in a significant proportion of these patients, it has been suggested that left atrial (LA) myopathy may predispose to CS-ESUS. We investigated alterations in echocardiographic measures of LA size and function in patients with CS-ESUS. METHODS: A systematic literature review and meta-analysis was performed. PubMed, EMBASE, Cochrane Library, Web of Science and SCOPUS were searched for articles published between 1 January 1990 and 10 February 2023. All observational studies of adult CS-ESUS patients with LA volume or function measurements performed by transthoracic echocardiogram were included. Individual random effects meta-analyses were performed on LA measurements in the CS-ESUS patients using subgroup analysis of comparator groups. RESULTS: We included 29 articles with 3927 CS-ESUS patients. Analysis of weighted mean differences showed CS-ESUS patients had altered LA structure and function parameters, with a larger maximum indexed LA volume, reduced LA emptying fraction and/or LA reservoir strain, compared to healthy controls and noncardioembolic stroke patients. Conversely, CS-ESUS patients had a smaller left atrium with better function, compared to cardioembolic stroke patients and CS-ESUS patients who subsequently developed atrial fibrillation. CONCLUSIONS: LA volume and function are altered in CS-ESUS patients compared to healthy controls and other stroke aetiologies. An underlying atrial myopathy in a subset of CS-ESUS patients may be involved in both thrombogenesis and dysrhythmia (specifically AF). While LA functional assessment is not currently recommended following stroke, it may offer an opportunity for recurrent stroke risk stratification.


Assuntos
Fibrilação Atrial , Ecocardiografia , AVC Embólico , Átrios do Coração , Humanos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , AVC Embólico/fisiopatologia , AVC Embólico/etiologia , AVC Embólico/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Função do Átrio Esquerdo/fisiologia , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/fisiopatologia , Acidente Vascular Cerebral/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA