Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int Heart J ; 62(6): 1257-1264, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34789643

RESUMO

Catheter ablation is a treatment modality which has been increasingly used for cardiac arrhythmias. However, it is not complication-free, and cardiac perforation is one of its most life-threatening complications. As surgery is usually not the first-line treatment for this emergent episode, there were only very few sporadic surgical reports in the literature. This systemic review primarily aims to collect different surgical approaches for catheter-induced cardiac perforation to help surgeons manage this kind of uncommon and critical patients. Of the 452 initially screened articles, 22 studies (38 patients) were included in the systemic review. Of all the included patients, 84% (32/38) were found to have pericardial effusion acutely following catheter-related procedures, and 16% (6/38) experienced delayed-onset episodes. Regarding the surgical procedures, four patients underwent removal of clots only, eight patients underwent suture repair of the left ventricle (LV), nine patients underwent suture repair of the right ventricle (RV), five patients underwent suture repair of the LA, and four patients underwent sutureless repair of the LV and pulmonary vein (LV 1, RV 1, pulmonary vein 1). In addition to repair of perforation sites, the concomitant combined procedures included repair of intercostal vessels (complication of pericardiocentesis) for one patient, cryoablation for two patients, and maze procedure for one patient. For cardiac perforation following catheter ablation or electrophysiology study, although the majority of the patients are treated with pericardiocentesis and medical management at first, cardiovascular surgeons have to prepare to take over if the bleeding is persistent or if the cardiac tamponade is not relieved.


Assuntos
Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Traumatismos Cardíacos/cirurgia , Traumatismos Cardíacos/etiologia , Humanos , Veias Pulmonares/lesões , Veias Pulmonares/cirurgia , Suturas
2.
BMC Cardiovasc Disord ; 20(1): 48, 2020 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-32013865

RESUMO

BACKGROUND: Three-dimensional electroanatomic mapping systems have demonstrated a significant reduction in radiation exposure during radiofrequency catheter ablation procedures. We aimed to investigate the safety, feasibility and efficacy of a completely zero-fluoroscopy approach for catheter ablation of supraventricular tachycardia using the Ensite NavX navigation system compared with a conventional fluoroscopy approach. METHODS: A multicenter prospective non-randomized registry study was performed in seven centers from January 2013 to February 2018. Consecutive patients referred for catheter ablation of supraventricular tachycardia were assigned either to a completely zero-fluoroscopic approach (ZF) or conventional fluoroscopy approach (CF) according to the operator's preference. Patients with atrial tachycardia were excluded. RESULTS: Totally, 1020 patients were enrolled in ZF group; 2040 patients ablated by CF approach were selected for controls. There was no significant difference between the zero-fluoroscopy group and conventional fluoroscopy group as to procedure time (60.3 ± 20.3 vs. 59.7 ± 22.6 min, P = 0.90), immediate success rate of procedure (98.8% vs. 99.2%, P = 0.22), arrhythmia recurrence (0.4% vs. 0.5%, P = 0.85), total success rate of procedure (98.4% vs. 98.8%, P = 0.39) or complications (1.1% vs. 1.5%, P = 0.41). Compared with the conventional fluoroscopy approach, the zero-fluoroscopy approach provided similar outcomes without compromising the safety or efficacy of the procedure. CONCLUSION: The completely zero-fluoroscopy approach demonstrated safety and efficacy comparable to a conventional fluoroscopy approach for catheter ablation of supraventricular tachycardia, and mitigated radiation exposure to both patients and operators. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT03042078; first registered February 3, 2017; retrospectively registered.


Assuntos
Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Cirurgia Assistida por Computador/instrumentação , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Adulto , Ablação por Cateter/efeitos adversos , China , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Recidiva , Sistema de Registros , Fatores de Risco , Cirurgia Assistida por Computador/efeitos adversos , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
Pediatr Cardiol ; 41(4): 709-715, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31974716

RESUMO

Children with ventricular pre-excitation are at risk for sudden death. This retrospective pediatric study identified patients > 8 years of age who had undergone electrophysiology study (EPS). Our primary objective was to determine the performance characteristics of non-invasive risk stratification. Subjects were separated into two groups. Group 1 was asymptomatic or had non-specific symptoms (palpitations, chest pain, and light headedness) without documented supraventricular tachycardia (SVT). Group 2 had syncope, documented SVT, or a life-threatening event. As a secondary aim, we tested whether patients with severe symptoms had a shorter time from the date of diagnosis to the date of invasive risk stratification. Among 93 patients with an average age of 14.2 years, 25 patients had documented SVT, 6 had syncope, and 1 had a life-threatening event. The sensitivity of non-invasive risk stratification was 7%. The specificity was 91%. The positive predictive valve was 14% and the negative predictive value was 84%. Even patients with severe symptoms commonly underwent non-invasive risk stratification prior to EPS, albeit at a lower rate (Group 1, 98%; Group 2 84%, p = 0.02). The median time to EPS was 4.2 months (Group 1) and 4.5 months (Group 2, p = 0.63). Non-invasive risk stratification was a poor predictor of invasive risk stratification. Cardiologists should counsel families about the limitations of non-invasive risk stratification and consider starting with invasive risk stratification and possible ablation. Counterintuitively, severe symptoms were not associated with a shorter time to electrophysiology study.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Síndromes de Pré-Excitação/diagnóstico , Taquicardia Supraventricular/diagnóstico , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade
4.
Am Heart J ; 207: 76-82, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30487072

RESUMO

BACKGROUND: Traditionally, insertable cardiac monitor (ICM) procedures have been performed in the cardiac catheterization (CATH) or electrophysiology (EP) laboratory. The introduction of the miniaturized Reveal LINQ ICM has led to simplified and less invasive procedures, affording hospitals flexibility in planning where these procedures occur without compromising patient safety or outcomes. METHODS: The present analysis of the ongoing, prospective, observational, multicenter Reveal LINQ Registry sought to provide real-world feasibility and safety data regarding the ICM procedure performed in the CATH/EP lab or operating room and to compare it with insertions performed outside of these traditional hospital settings. Patients included had at least a 30-day period after the procedure to account for any adverse events. RESULTS: We analyzed 1222 patients (58.1% male, age 61.0 ± 17.1 years) enrolled at 18 centers in the US, 17 centers in Middle East/Asia, and 15 centers in Europe. Patients were categorized into 2 cohorts according to the location of the procedure: in-lab (CATH lab, EP lab, or operating room) (n = 820, 67.1%) and out-of-lab (n = 402, 32.9%). Several differences were observed regarding baseline and procedure characteristics. However, no significant differences in the occurrence of procedure-related adverse events (AEs) were found; of 19 ICM/procedure-related AEs reported in 17 patients (1.4%), 11 occurred in the in-lab group (1.3%) and 6 in the out-of-lab group (1.5%) (P = .80). CONCLUSIONS: This real-world analysis demonstrates the feasibility of performing Reveal LINQ ICM insertion procedures outside of the traditional hospital settings without increasing the risk of infection or other adverse events.


Assuntos
Cateterismo Cardíaco/estatística & dados numéricos , Unidades de Cuidados Coronarianos/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/métodos , Salas Cirúrgicas/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Europa (Continente) , Ásia Oriental , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Miniaturização , Segurança do Paciente , Estudos Prospectivos , Sistema de Registros , Estados Unidos , Adulto Jovem
5.
J Cardiovasc Electrophysiol ; 30(8): 1287-1293, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31240813

RESUMO

AIMS: Acute cardiac tamponade (ACT) is the most common life-threatening complication of interventional electrophysiology. Urgent drainage by percutaneous pericardiocentesis and anticoagulation reversal are required. Immediate direct transfusion of the blood volume aspirated from the pericardial space to the patient has been rarely described. This study was designed to assess the efficacy and safety of immediate direct autologous blood transfusion (AutoBT). METHODS: A retrospective case series of direct AutoBT performed for ACT was collected. Urgent drainage by percutaneous pericardiocentesis and immediate direct AutoBT were performed to achieve hemodynamic stabilization without a cell-saver system. RESULTS: Twenty-two electrophysiology centers were contacted to participate in the case series. Fourteen centers reported not to use direct AutoBT. Three centers reported using direct AutoBT with the cell-saver system. Fourteen cases of immediate direct AutoBT without cell-saver system were included from the five remaining centers. Electrophysiological procedures were performed for ventricular tachycardia (n = 5), atrial fibrillation (n = 5), atrial tachycardia (n = 2), left accessory pathway (n = 1), and premature ventricular contraction (n = 1) with transseptal (n = 9), retroaortic (n = 4), and/or epicardial access (n = 4). Pericardial drainage was performed by percutaneous pericardiocentesis for 13 patients and via the transseptal sheath for one patient. Surgical hemostasis was required for seven patients. The mean volume of autologous blood directly transfused was 1207 ± 963 mL. Direct AutoBT permitted to resume the procedure in four patients. No major complication related to the use of AutoBT occurred. CONCLUSION: Direct AutoBT without a cell-saver system is a feasible, safe, and useful technique for salvage therapy in ACT in interventional electrophysiology.


Assuntos
Arritmias Cardíacas/terapia , Transfusão de Sangue Autóloga , Cateterismo Cardíaco/efeitos adversos , Tamponamento Cardíaco/terapia , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Transfusão de Sangue Autóloga/efeitos adversos , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/fisiopatologia , Estudos de Viabilidade , Feminino , França , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Pericardiocentese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Terapia de Salvação , Fatores de Tempo , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 30(9): 1602-1609, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31190453

RESUMO

INTRODUCTION: Emerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration-approved AliveCor Kardia device in patients with CIEDs. METHODS AND RESULTS: We prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1). CONCLUSION: The AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Frequência Cardíaca , Aplicativos Móveis , Marca-Passo Artificial , Tecnologia de Sensoriamento Remoto/instrumentação , Smartphone , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Artefatos , Estimulação Cardíaca Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Tecnologia de Sensoriamento Remoto/efeitos adversos , Reprodutibilidade dos Testes , Fatores de Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo
7.
J Cardiovasc Electrophysiol ; 30(11): 2397-2404, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31424119

RESUMO

AIMS: The use of electroanatomical mapping (EAM) systems can reduce radiation exposure (RX) and it can also completely eliminate the use of RX. Radiation exposure related to conventional radiofrequency ablation procedures can have a stochastic and deterministic effect on health. The main aim of this study was to evaluate the safety and feasibility of an entirely nonfluoroscopic approach to catheter ablation (CA) using EAM CARTO3. METHODS: In 2011 we started an RX-minimization programme in all procedures using the CARTO system with the deliberate intention to not resort to the aid of RX unless strictly necessary. We divided procedures into two groups (group 1: from 2011 to 2013; group 2: from 2014 to 2017). The only exclusion criteria were the need for transseptal puncture, and nonidiopathic ventricular tachycardia (VT). RESULTS: From a total of 525 procedures, we performed CA entirely without RX in 78.5% of cases. From 2011 to 2013, we performed CA without RX in 38.5% of cases; from 2014 to 2017, we performed 96.2% of cases with zero RX. The use of RX was significantly reduced in group 2 (group 2: 1.4 ± 19.6 seconds vs group 1: 556.92 ± 520.76 seconds; P < .001). These differences were irrespective of arrhythmia treatment. There were no differences between the two groups in acute success, complications, or duration of procedures. CONCLUSION: CA of supraventricular tachycardia and VT entirely without RX, guided by the CARTO system, is safe, feasible, and effective. After an adequate learning curve, CA can be performed entirely without RX.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Cirurgia Assistida por Computador , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Competência Clínica , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Cirurgia Assistida por Computador/instrumentação , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
8.
J Cardiovasc Nurs ; 34(6): 517-527, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31441801

RESUMO

BACKGROUND: There are only limited data about peri-interventional pain during cardiac electrophysiological procedures without analgosedation. In this study, peri-interventional pain and recollection of it after the intervention were evaluated. METHODS: A total of 101 patients (43 electrophysiological/ablation procedures and 58 device surgeries) reported pain on a numerical rating scale (NRS; 0-10) before (pre), during (peri), and after (post) the intervention. Maximum pain (maxNRS) and the average of pain (meanNRS) were used for statistical analysis. Peri-interventional pain was compared with postinterventional data of the recollection of peri-interventional pain (peri-post). Patients were allocated into 2 groups (with 51 and 50 patients, respectively) to evaluate the mode of patient-staff interaction on pain recollection. Depressive, anxiety, and somatic symptom scales (Patient Health Questionnaire-15, Generalized Anxiety Disorder-7, and Patient Health Questionnaire-15) were used to analyze their influence on pain recollection. RESULTS: In total, 49.6% of patients (n = 50) complained of moderate to severe pain (maxNRS) at least once during the procedure. The comparison between peri and peri-post data revealed the following (median (range)-maxNRS, peri: 3 (0-10) versus peri-post: 4 (0-9) (ns), and meanNRS, peri: 1.4 (0-7) versus peri-post: 2.0 (0-6) (ns). The mode of patient-staff interaction had no influence on pain. No effect was found for psychosocial factor concerning pain and the recollection of pain. The results of the linear regression showed no influence of low-dose midazolam on recollection of pain. CONCLUSION: Half of the patients reported moderate to severe pain at least once during cardiac electrophysiological procedures without analgosedation. However, on average, patients reported only low pain levels. Postinterventional derived data on discomfort reflect the peri-interventional situation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Dor Processual/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Processual/epidemiologia , Questionário de Saúde do Paciente , Projetos Piloto , Estudos Prospectivos
9.
J Pak Med Assoc ; 69(1): 68-71, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30623915

RESUMO

OBJECTIVE: To review 10 years of clinical practice of cardiac electrophysiology study and radiofrequency catheter ablation in the treatment of supraventricular tachycardia. METHODS: The retrospective chart review was conducted at the National Institute of Cardiovascular Diseases, Karachi, and comprised records of all patients who underwent electrophysiological study and / or radiofrequency catheter ablation from January2007 to December 2016. SPSS 21 was used for data analysis. RESULTS: Of the 627 patients, 335(53.4%) were females. The overall mean age was 40.99}13.59 years. The major indication for procedure was supraventricular tachycardia 376(59.97%). Final electrophysiological study diagnosis was typical slow fast atrioventricular nodal re-entrant tachycardia in 303(48.3%) patients. The overall success rate was 472(75.3%). Procedure-related complications were reported in 25(4%) patients, and there was 1(0.15%) mortality. CONCLUSIONS: Cardiac electrophysiology studies and radiofrequency catheter ablation were found to be an effective and safe method for diagnosis and treatment of supraventricular tachycardia.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia por Reentrada no Nó Sinoatrial , Taquicardia Supraventricular , Síndrome de Wolff-Parkinson-White , Adulto , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Diagnóstico Diferencial , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Paquistão/epidemiologia , Taquicardia por Reentrada no Nó Sinoatrial/diagnóstico , Taquicardia por Reentrada no Nó Sinoatrial/epidemiologia , Taquicardia por Reentrada no Nó Sinoatrial/terapia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/terapia , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/epidemiologia , Síndrome de Wolff-Parkinson-White/terapia
10.
Prof Inferm ; 72(3): 181-186, 2019.
Artigo em Italiano | MEDLINE | ID: mdl-31883569

RESUMO

INTRODUCTION: Coronary interventions and electrophysiology procedures may be painful both during and shortly after the procedure. AIM: To assess the onset of pain and anxiety in patient undergoing coronary interventions and electrophysiology procedures; to describe the administration (frequency, timing, dosage and outcomes) of analgesics and anxiolytics before, during and after the procedure. METHODS: A descriptive multicenter study was carried out. Pain and anxiety were measured with a 10-point visual analogue scale (VAS) before, during, after the procedure and for the following 24 hours. Patient were asked to rate their satisfaction for the information received and pain control. RESULTS: Data on 230 patients were collected. The most performed procedure was the transradial coronary catheterization (68.7%). The pacemaker/defibrillator implantation resulted the most painful procedure (median 4, IQR 3-6) and also the most anxious (median 5, IQR 2-6). 13 Patients received an analgesic during the procedure for a low-to-severe pain; during the following 24 hours 34 patients (5 undergoing transradial coronary catheterization and 29 the implant of pacemaker/cardiac-defibrillator) suffered from severe pain and with the exception of 5, all requested pain relief. Satisfaction for pain control was inadequate for patients who underwent electrophysiology procedures and 55 patients would have needed more information on pain. CONCLUSION: Pain control and patient satisfaction may be improved, pre-procedural anxiety needs more attention and better information on the procedure should be provided.


Assuntos
Analgésicos/administração & dosagem , Ansiolíticos/administração & dosagem , Ansiedade/prevenção & controle , Dor Processual/prevenção & controle , Idoso , Ansiedade/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Masculino , Medição da Dor , Dor Processual/epidemiologia , Dor Processual/psicologia , Satisfação do Paciente
11.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29064134

RESUMO

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Assuntos
Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional/prevenção & controle , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Proteção , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
12.
Europace ; 19(7): 1198-1203, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28201731

RESUMO

Introduction: Advances in 3D electroanatomic-mapping technologies have resulted in a safe and effective profile of radiofrequency (RF) catheter ablation. The aim of this study was to evaluate a different catheter ablation approach in patients with left-sided accessory pathways (APs). Methods and results: From January 2015 to December 2015, 30 patients (median age 11 years, median weight 45 kg) with manifest or concealed left-sided APs underwent RF catheter ablation with a new protocol. All procedures were performed with the CARTO UNIVU™ system, integrating electroanatomic maps with fluoroscopic views. A 7 Fr ablation catheter was inserted into the right femoral vein and advanced into the right atrium. Geometrical reconstruction and activation map of the right atrium, tricuspid annulus, and coronary sinus were acquired. The ablation catheter was then inserted into the left femoral artery and advanced through the aorta and aortic valve, creating an activation map of the mitral annulus. Catheter ablation was targeted to the site of the earliest activation. No complications occurred. The median procedure and fluoroscopy times were 130 min and 6 s, with a median fluoroscopy dose 0.5 mGy. An average of two catheters was used. Long-term success rate was 97% (29/30) at a median follow-up of 9.6 months. This approach reduced fluoroscopy time, dose and number of catheters used compared with manifest or concealed left-sided AP ablation using CARTO 3™ (P < 0.05). Conclusions: This new ablation protocol seems to be promising in reducing fluoroscopy exposure and number of catheters used during left-sided AP ablation in children.


Assuntos
Feixe Acessório Atrioventricular , Arritmias Cardíacas/cirurgia , Técnicas Eletrofisiológicas Cardíacas/métodos , Radiografia Intervencionista/métodos , Potenciais de Ação , Adolescente , Fatores Etários , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Criança , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Masculino , Duração da Cirurgia , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
13.
Europace ; 19(3): 458-464, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26896467

RESUMO

AIMS: Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. METHODS AND RESULTS: Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. CONCLUSIONS: This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Imageamento por Ressonância Magnética , Animais , Artefatos , Cateterismo Cardíaco/efeitos adversos , Cateteres Cardíacos/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Estudos de Viabilidade , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Teste de Materiais , Modelos Animais , Imagens de Fantasmas , Valor Preditivo dos Testes , Carneiro Doméstico , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
14.
Europace ; 18(9): 1406-10, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26589627

RESUMO

AIMS: This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. METHODS AND RESULTS: From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose-area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). CONCLUSION: The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Cineangiografia/métodos , Angiografia Coronária/métodos , Técnicas Eletrofisiológicas Cardíacas , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Adulto , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Cineangiografia/efeitos adversos , Angiografia Coronária/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 26(5): 527-31, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25684120

RESUMO

BACKGROUND: Despite growing attention to performance and quality measures, national standards for reporting of outcomes after all electrophysiology (EP) procedures have not yet been developed. We sought to characterize the incidence and timing of adverse events up to 30 days after EP procedures at a tertiary academic medical center. METHODS AND RESULTS: We prospectively followed all patients undergoing EP procedures between January 2010 and September 2012. All were followed for 30 days postprocedure either in clinic or by telephone. Major complications were defined as events related to the procedure that led to prolongation of hospital stay or readmission, required additional procedural intervention, or resulted in death or significant injury. These were further categorized as intraprocedure, postprocedure, or postdischarge events. Seven EP physicians collectively adjudicated whether complications were directly related to the procedure. A total of 3,213 procedures were performed. Major complications occurred in 2.2% of patients; 49% of these events occurred after discharge. Death occurred in 0.6% of patients; 73% of these deaths were found to be secondary to worsening of the patient's underlying comorbid conditions and unrelated to the procedure. CONCLUSIONS: When considering national standards for reporting outcomes of all EP procedures, continued follow-up after discharge is important. In our cohort, half of major complications occurring within 30 days occurred after discharge. In addition, three-quarters of deaths within 30 days were not directly related to the procedure and caution should be used in using all-cause mortality as an outcome measure for EP procedures.


Assuntos
Centros Médicos Acadêmicos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cateterismo Cardíaco/mortalidade , Ablação por Cateter/mortalidade , Técnicas Eletrofisiológicas Cardíacas/mortalidade , Complicações Pós-Operatórias/mortalidade , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/normas , Ablação por Cateter/efeitos adversos , Ablação por Cateter/normas , Causas de Morte , Comorbidade , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/normas , Humanos , Incidência , Tempo de Internação , Readmissão do Paciente , Complicações Pós-Operatórias/diagnóstico , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Estudos Prospectivos , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Virginia
16.
Pacing Clin Electrophysiol ; 38(10): 1173-80, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26137999

RESUMO

INTRODUCTION: There are several methods to induce ventricular fibrillation (VF) during defibrillation threshold (DFT) testing. Delivering a shock at a critical time during the T wave (T-shock) is the conventional approach, while delivering a constant direct current voltage (DC stim) from the implantable cardioverter defibrillator is an alternative method. Only a few reports compare VF induction methods. The purpose of this study was to evaluate the effects and safety of DC stim versus T-shock. METHODS: We retrospectively investigated 414 consecutive patients undergoing DFT testing. We compared the two groups (DC stim and T-shock) with respect to clinical characteristics, electrocardiogram (ECG) changes, and complications. RESULTS: Ventricular arrhythmia, including ventricular tachycardia (VT) and VF, was induced by DC stim in 93 patients or T-shock in 321 patients. No more than three attempts were performed during one procedure. There was no significant difference in the baseline ECG, induced tachycardia cycle length (TCL), or complications between the two groups. However, the induced TCL was significantly shorter than the clinical TCL regardless of induction method (P = 0.001). Five patients suffered major complications (i.e., electromechanical dissociation or incessant VT). A history of atrial fibrillation was significantly greater in patients with major complications than the others (80% vs 24%, P = 0.004), and was an independent predictor on multivariate analysis. CONCLUSIONS: There is no significant difference in induced TCL or complications between the DC stim and T-shock. The induced TCL is significantly shorter than clinical TCL regardless of induction method.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Estimulação Elétrica/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Disfunção Ventricular Esquerda/epidemiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Limiar Diferencial , Estimulação Elétrica/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , São Francisco/epidemiologia , Distribuição por Sexo , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Fibrilação Ventricular/epidemiologia
17.
Europace ; 16(7): 946-64, 2014 07.
Artigo em Inglês | MEDLINE | ID: mdl-24792380

RESUMO

Despite the advent of non-fluoroscopic technology, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies over ablation interventions to device implantation. Moreover, many patients receive additional X-ray imaging, such as cardiac computed tomography and others. More and more complex procedures have the risk to increase the radiation exposure, both for the patients and the operators. The professional lifetime attributable excess cancer risk may be around 1 in 100 for the operators, the same as for a patient undergoing repetitive complex procedures. Moreover, recent reports have also hinted at an excess risk of brain tumours among interventional cardiologists. Apart from evaluating the need for and justifying the use of radiation to assist their procedures, physicians have to continuously explore ways to reduce the radiation exposure. After an introduction on how to quantify the radiation exposure and defining its current magnitude in electrophysiology compared with the other sources of radiation, this position paper wants to offer some very practical advice on how to reduce exposure to patients and staff. The text describes how customization of the X-ray system, workflow adaptations, and shielding measures can be implemented in the cath lab. The potential and the pitfalls of different non-fluoroscopic guiding technologies are discussed. Finally, we suggest further improvements that can be implemented by both the physicians and the industry in the future. We are confident that these suggestions are able to reduce patient and operator exposure by more than an order of magnitude, and therefore think that these recommendations are worth reading and implementing by any electrophysiological operator in the field.


Assuntos
Cateterismo Cardíaco/normas , Técnicas Eletrofisiológicas Cardíacas/normas , Exposição Ocupacional/normas , Implantação de Prótese/normas , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista/normas , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Fluoroscopia/normas , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Saúde Ocupacional/normas , Segurança do Paciente/normas , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Lesões por Radiação/etiologia , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/instrumentação , Medição de Risco , Fatores de Risco , Fluxo de Trabalho
18.
Pacing Clin Electrophysiol ; 37(6): 781-90, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24697803

RESUMO

Administration of intravenous sedation (IVS) has become an integral component of procedural cardiac electrophysiology. IVS is employed in diagnostic and ablation procedures for transcutaneous treatment of cardiac arrhythmias, electrical cardioversion of arrhythmias, and the insertion of implantable electronic devices including pacemakers, defibrillators, and loop recorders. Sedation is frequently performed by nursing staff under the supervision of the proceduralist and in the absence of specialist anesthesiologists. The sedation requirements vary depending on the nature of the procedure. A wide range of sedation techniques have been reported with sedation from the near fully conscious to levels approaching that of general anesthesia. This review examines the methods employed and outcomes associated with reported sedation techniques. There is a large experience with the combination of benzodiazepines and narcotics. These drugs have a broad therapeutic range and the advantage of readily available reversal agents. More recently, the use of propofol without serious adverse events has been reported. The results provide a guide regarding the expected outcomes of these approaches. The complication rate and need for emergency assistance is low in reported series where sedation is administered by nonspecialist anesthesiology staff.


Assuntos
Anestesia Geral/métodos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Hipnóticos e Sedativos/administração & dosagem , Dor/etiologia , Dor/prevenção & controle , Humanos
19.
Vestn Khir Im I I Grek ; 173(5): 23-6, 2014.
Artigo em Russo | MEDLINE | ID: mdl-25823330

RESUMO

The standard transvenous electrocardiostimulation (ECS) is currently used in many specialized hospitals. The authors offered and launched systematic application of simple but available technique of epymiocardiac ECS using pericardoscopy since middle of 80th. According to this principle, the authors developed some diversities of manipulation which are distinctive due to their availability, reliability and supersafety. The method could be recommended for wide-spread usage in practice because of high efficacy, few complications and absence of fatal outcomes in correct intervention. Described methods used in treatment of considerable quantity of patients and adapted to real work conditions of public health hospitals.


Assuntos
Arritmias Cardíacas/terapia , Técnicas Eletrofisiológicas Cardíacas , Complicações Pós-Operatórias , Toracoscopia , Arritmias Cardíacas/diagnóstico , Pesquisa Comparativa da Efetividade , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Humanos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Reprodutibilidade dos Testes , Toracoscopia/efeitos adversos , Toracoscopia/métodos
20.
Genes (Basel) ; 15(3)2024 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-38540339

RESUMO

Popeye domain-containing (POPDC) proteins selectively bind cAMP and mediate cellular responses to sympathetic nervous system (SNS) stimulation. The first discovered human genetic variant (POPDC1S201F) is associated with atrioventricular (AV) block, which is exacerbated by increased SNS activity. Zebrafish carrying the homologous mutation (popdc1S191F) display a similar phenotype to humans. To investigate the impact of POPDC1 dysfunction on cardiac electrophysiology and intracellular calcium handling, homozygous popdc1S191F and popdc1 knock-out (popdc1KO) zebrafish larvae and adult isolated popdc1S191F hearts were studied by functional fluorescent analysis. It was found that in popdc1S191F and popdc1KO larvae, heart rate (HR), AV delay, action potential (AP) and calcium transient (CaT) upstroke speed, and AP duration were less than in wild-type larvae, whereas CaT duration was greater. SNS stress by ß-adrenergic receptor stimulation with isoproterenol increased HR, lengthened AV delay, slowed AP and CaT upstroke speed, and shortened AP and CaT duration, yet did not result in arrhythmias. In adult popdc1S191F zebrafish hearts, there was a higher incidence of AV block, slower AP upstroke speed, and longer AP duration compared to wild-type hearts, with no differences in CaT. SNS stress increased AV delay and led to further AV block in popdc1S191F hearts while decreasing AP and CaT duration. Overall, we have revealed that arrhythmogenic effects of POPDC1 dysfunction on cardiac electrophysiology and intracellular calcium handling in zebrafish are varied, but already present in early development, and that AV node dysfunction may underlie SNS-induced arrhythmogenesis associated with popdc1 mutation in adults.


Assuntos
Bloqueio Atrioventricular , Cálcio , Adulto , Animais , Humanos , Cálcio/metabolismo , Peixe-Zebra/genética , Peixe-Zebra/metabolismo , Nó Atrioventricular/metabolismo , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Bloqueio Atrioventricular/complicações , Arritmias Cardíacas/genética , Doença do Sistema de Condução Cardíaco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA