Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.029
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr ; 271: 114086, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38705232

RESUMO

OBJECTIVE: To evaluate associations between neurologic outcomes and early measurements of basal ganglia (BG) and thalamic (Th) perfusion using color Doppler ultrasonography (CDUS) in infants with hypoxic-ischemic encephalopathy (HIE). STUDY DESIGN: Prospective study of infants with mild (n = 18), moderate (n = 17), and severe HIE (n = 14) and controls (n = 17). Infants with moderate-severe HIE received therapeutic hypothermia (TH). CDUS was performed at 24-36 hours and brain magnetic resonance imaging (MRI) at a median of 10 days. Development was followed through 2.5-5 years. The primary outcome was the association between BG and Th perfusion and brain MRI injury. Secondary analyses focused on associations between perfusion measurements and admission neurologic examinations, MRI scores in infants treated with TH, and motor and sensory disability, or death. An exploratory analysis assessed the accuracy of BG and Th perfusion to predict brain MRI injury in infants treated with TH. RESULTS: Increased BG and Th perfusion on CDUS was observed in infants with severe MRI scores and those with significant motor and neurosensory disability or death through 2.5-5 years (P < .05). Infants with severe HIE showed increased BG and Th perfusion (P < .005) compared with infants with moderate HIE. No differences were identified between the between the control and mild HIE groups. Th perfusion ≥0.237 cm/second (Area under the curve of 0.824) correctly classified 80% of infants with severe MRI scores. CONCLUSIONS: Early dynamic CDUS of the BG and Th is a potential biomarker of severe brain injury in infants with HIE and may be a useful adjunct to currently used assessments.


Assuntos
Gânglios da Base , Hipotermia Induzida , Hipóxia-Isquemia Encefálica , Imageamento por Ressonância Magnética , Tálamo , Ultrassonografia Doppler em Cores , Humanos , Gânglios da Base/diagnóstico por imagem , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Hipóxia-Isquemia Encefálica/terapia , Estudos Prospectivos , Masculino , Feminino , Ultrassonografia Doppler em Cores/métodos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Tálamo/diagnóstico por imagem , Lactente , Lesões Encefálicas/diagnóstico por imagem
2.
J Pediatr Hematol Oncol ; 46(3): e233-e240, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38408130

RESUMO

OBJECTIVE: To investigate superb microvascular imaging (SMI), a novel Doppler ultrasound technique that can visualize low-velocity microvascular flow, for assessing pediatric focal nodular hyperplasia (FNH). PATIENTS AND METHODS: Nine FNH lesions in 6 patients were enrolled. On SMI and color Doppler imaging (CDI), intralesional vascularity was assessed visually and categorized as typical spoke-wheel pattern (central vessel radiating from the center to the periphery), multifocal spoke-wheel pattern, and nonspecific pattern. We compared the vascular features of the lesions between SMI and CDI and evaluated vascular patterns according to lesion size. RESULTS: In terms of vascularity pattern, the typical spoke-wheel pattern of FNH was noted more frequently on SMI (67%) than on CDI (11%; P < 0.05). In addition, a multifocal spoke-wheel pattern was noted in all remaining lesions (33%) on SMI. On the contrary, a nonspecific vascular pattern was detected in the majority (78%) of CDI. Regarding the lesion size and vascularity on SMI, the typical spoke-wheel pattern was seen more frequently in the small FNH group than in the large FNH group. The intralesional vascular signal was detected more frequently on SMI (100%) than on CDI (89%). CONCLUSION: SMI is feasible in evaluating FNH in children and has a greater ability to demonstrate the spoke-wheel pattern than CDI.


Assuntos
Hiperplasia Nodular Focal do Fígado , Humanos , Criança , Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Hiperplasia Nodular Focal do Fígado/patologia , Meios de Contraste , Diagnóstico Diferencial , Ultrassonografia , Ultrassonografia Doppler em Cores/métodos
3.
Clin Radiol ; 79(4): e560-e566, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38336532

RESUMO

AIM: To compare the efficacy of quantitative contrast-enhanced ultrasonography (CEUS) analysis and colour Doppler ultrasound (CDU) in evaluating central retinal artery (CRA) microcirculation in patients with diabetes mellitus (DM). MATERIALS AND METHODS: In this prospective study, a total of 55 patients (98 eyes) with DM were enrolled as the study group. They were compared to 46 age-matched healthy volunteers (92 eyes) who were selected as the control group. Each patient underwent CDU and subsequent CEUS examination. CDU and quantitative CEUS parameters were evaluated. The diagnostic efficiency of the diagnostic performance of CEUS and CDU was evaluated and compared, and the scale thresholds of predictive indicators for the diagnosis of proliferative diabetic retinopathy (PDR) were evaluated using receiver operating characteristics (ROC) curve analyses. RESULTS: Group pairwise comparisons showed that the end diastolic velocity (EDV) and arrival time (AT) of CRA were significant predictors for PDR by CDU and by quantitative CEUS analysis, respectively (all p<0.05). The ROC curve analysis showed that the area under the curve value of AT was significantly higher than that of EDV (0.875 versus 0.634, p=0.0002). Accordingly, an AT cut-off value of 1.07 seconds resulted a sensitivity of 90.62 % and a specificity of 79.31 %. CONCLUSION: Quantitative CEUS analysis can improve the accuracy of clinical staging of diabetic retinopathy for the patients with DM, and the AT showed the best diagnostic efficiency.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Artéria Retiniana , Humanos , Artéria Retiniana/diagnóstico por imagem , Retinopatia Diabética/diagnóstico por imagem , Microcirculação , Estudos Prospectivos , Cor , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Meios de Contraste
4.
Clin Radiol ; 79(1): e48-e56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37932209

RESUMO

AIM: To evaluate the value of non-contrast micro-flow imaging (MFI) and high-definition micro-flow imaging (HD-MFI) in differentiating malignant and benign breast lesions. MATERIALS AND METHODS: One hundred and thirty-three patients with 138 breast lesions (80 benign and 58 malignant lesions) were examined using colour Doppler flow imaging (CDFI), MFI, and HD-MFI before biopsy, with blood flow signals graded into four types (grade 0, 1, 2, and 3) and penetrating vessels evaluated. The micro-vascular patterns of MFI and HD-MFI were evaluated and classified into five patterns: avascular, line-like, tree-like, root hair-like, and crab claw-like pattern. The diagnostic efficiency of micro-vascular patterns was analysed. Moreover, ultrasound Breast Imaging Reporting and Data System (BI-RADS) 4A lesions were also re-assessed according to the micro-vascular patterns of MFI or HD-MFI. RESULTS: The capability of detecting blood flow and penetrating vessels from high to low was HD-MFI, MFI, and CDFI, respectively (p<0.05). Rich blood flow signals, penetrating vessels, and root hair-like or crab claw-like pattern were more likely in malignant breast lesions, while few blood flow signals, tree-like pattern were mostly in benign lesions (p<0.05). The diagnostic efficiency of HD-MFI and MFI were higher than CDFI (p>0.05). MFI could reduce unnecessary biopsy of 52 US BI-RADS 4A lesions but with two malignancies missed, while 56 ultrasound BI-RADS 4A lesions could be downgraded by HD-MFI with none malignancies missed. CONCLUSIONS: MFI and HD-MFI can detect more blood flow in breast lesions than CDFI, and could help distinguish benign and malignant breast lesions. HD-MFI could reduce the unnecessary biopsy of US BI-RADS 4A lesions without missed malignancy.


Assuntos
Neoplasias da Mama , Neoplasias , Humanos , Feminino , Mama/diagnóstico por imagem , Mama/patologia , Ultrassonografia , Neoplasias/patologia , Ultrassonografia Doppler em Cores/métodos , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Ultrassonografia Mamária/métodos
5.
BMC Womens Health ; 24(1): 544, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39354424

RESUMO

OBJECTIVE: To exploit the combination diagnostic performance of serum microRNA-134-5p (miR-134-5p) and color Doppler ultrasound in patients with endometriosis patients. METHODS: Quantitative real time polymerase chain reaction (qRT-PCR) analysis was applied to measure relative abundance of miR-134-5p in serum of patients with endometriosis and gynecological benign diseases. Calculation of uterine artery blood flow parameters was conducted using Color Doppler ultrasound. Receiver operating characteristic (ROC) curve was established to evaluate the diagnostic capacity of miR-134-5p and Doppler parameters. Kaplan-Meier method was used for the analysis of recurrence-free survival rate. RESULTS: Compared with the control group, serum miR-134-5p expression was remarkably diminished in endometriosis patients (P < 0.001). End-diastolic velocity (EDV) and peak systolic velocity (PSV) were notably decreased in endometriosis patients compared with the control group (P < 0.001), while pulsatility index (PI) and resistance index (RI) were distinctly increased (P < 0.001). Serum miR-134-5p expression was positively correlated with EDV (r = 0.5777, P < 0.0001) and PSV (r = 0.6945, P < 0.0001), but negatively correlated with PI (r=-0.6382, P < 0.0001) and RI (r=-0.6247, P < 0.0001). The area under the ROC curve (AUC) of serum miR-134-5p combined with Doppler parameters was 0.905, with the sensitivity of 87.40%, and the specificity of 82.29%. The recurrence-free survival time was shorter in patients with low miR-134-5p expression than those with high miR-134-5p expression (P = 0.013). CONCLUSION: A better diagnostic value of endometriosis detection could be obtained when serum miR-134-5p was combined with Doppler parameters.


Assuntos
Endometriose , MicroRNAs , Ultrassonografia Doppler em Cores , Artéria Uterina , Humanos , Feminino , MicroRNAs/sangue , Ultrassonografia Doppler em Cores/métodos , Adulto , Endometriose/sangue , Endometriose/diagnóstico por imagem , Artéria Uterina/diagnóstico por imagem , Curva ROC , Velocidade do Fluxo Sanguíneo/fisiologia , Estudos de Casos e Controles , Biomarcadores/sangue , Relevância Clínica
6.
BMC Med Imaging ; 24(1): 10, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172706

RESUMO

BACKGROUND: Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) provide accurate vascular imaging information, but their use may be contraindicated. Color Doppler ultrasonography (CDU) provides simple, safe, noninvasive, and reproducible imaging. We therefore investigated the role of preoperative CDU combined with CTA and MRA in the quantification, typing, and diagnosis of carotid body tumors (CBTs). METHODS: We retrospectively analyzed patients with CBTs categorized into group A (type I [n = 1] and type II [n = 10]) or group B (type III [n = 56]) per the intraoperative Shamblin classification. CDU, CTA, and MRA characteristics of CBTs were observed, surgical results were correlated, and the diagnostic threshold of the CBT classification was calculated. RESULTS: CBTs were usually located at the common carotid artery bifurcation, encircling the carotid artery. An increased angle was found between the internal and external carotid arteries. On CDU, CBTs primarily presented as homogeneous hypoechoic masses with clear boundaries, rich flow signals, and a high-speed, low-resistance artery-like flow spectrum. CTA showed uniform or heterogeneous marked enhancement. MRA showed mixed T1 and slightly longer T2 signals and uniform or uneven obvious enhancement. With increases in the lesion size, amount of blood transfused, and operation time, the intraoperative classification level and possibility of skull-base invasion increased. When the maximum diameter of the lesion, the volume of the tumor, the distance between the upper margin of the tumor to the mastoid and the mandibular angle were 3.10 cm, 10.15 cm3, - 3.26 cm, and 0.57 cm, respectively, the largest Youden index was the best diagnostic boundary value for Shamblin type III tumors. CONCLUSIONS: CDU combined with CTA and MRA can accurately evaluate the size and classification of CBTs.


Assuntos
Tumor do Corpo Carotídeo , Angiografia por Tomografia Computadorizada , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética , Estudos Retrospectivos , Tumor do Corpo Carotídeo/patologia , Tumor do Corpo Carotídeo/cirurgia , Ultrassonografia Doppler em Cores/métodos
7.
BMC Med Imaging ; 24(1): 282, 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39434033

RESUMO

BACKGROUND: It is challenging to correctly identify and diagnose breast nonmass lesions. This study aimed to explore the multimodal ultrasound features associated with malignant breast nonmass lesions (NMLs), and evaluate their combined diagnostic performance. METHODS: This retrospective analysis was conducted on 573 breast NMLs, including 309 were benign and 264 were malignant, their multimodal ultrasound features (B-mode, color Doppler and strain elastography) were assessed by two experienced radiologists. Univariate and multivariate logistic regression analysises were used to explore multimodal ultrasound features associated with malignancy, and a nomogram was developed. Diagnostic performance and clinical utility were evaluated and validated by the receiver operating characteristic (ROC) curve, calibration curve and decision curve in the training and validation cohorts. RESULTS: Multimodal ultrasound features including linear (odds ratio [OR] = 4.69) or segmental distribution (OR = 7.67), posterior shadowing (OR = 3.14), calcification (OR = 7.40), hypovascularity (OR = 0.38), elasticity scored 4 (OR = 7.00) and 5 (OR = 15.77) were independent factors associated with malignant breast NMLs. The nomogram based on these features exhibited diagnostic performance in the training and validation cohorts were comparable to that of experienced radiologists, with superior specificity (89.4%, 89.5% vs. 81.2%) and positive predictive value (PPV) (89.2%, 90.4% vs. 82.4%). The nomogram also demonstrated good calibration in both training and validation cohorts (all P > 0.05). Decision curve analysis indicated that interventions guided by the nomogram would be beneficial across a wide range of threshold probabilities (0.05-1 in the training cohort and 0.05-0.93 in the validation cohort). CONCLUSIONS: The combined use of linear or segmental distribution, posterior shadowing, calcification, hypervascularity and high elasticity score, displayed as a nomogram, demonstrated satisfied diagnostic performance for malignant breast NMLs, which may contribute to the imaging interpretation and clinical management of tumors.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Nomogramas , Ultrassonografia Mamária , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Idoso , Curva ROC , Imagem Multimodal/métodos , Ultrassonografia Doppler em Cores/métodos
8.
BMC Med Imaging ; 24(1): 239, 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39272005

RESUMO

OBJECTIVE: We aimed to probe the diagnostic value of transvaginal color Doppler ultrasound (TV-CDU) parameters in cesarean scar pregnancy (CSP) and CSP sub-types, and the relevant factors affecting patients' surgical effects. METHODS: Seventy-five CSP patients (all requested termination of pregnancy) were selected as the observation group, and 75 normal pregnant women with a history of cesarean section were selected as the control group. All the study subjects underwent TV-CDU and their cesarean scar muscle (CSM) thickness, minimum sagittal muscle thickness and resistance index (RI) of blood flow in the anterior wall of the lower uterine segment were calculated. The diagnostic value of CSM, minimum sagittal muscle thickness, and RI for CSP and CSP sub-types was analyzed. The patients in the observation group were grouped into the effective group and the ineffective group according to whether the surgical treatment was effective or not, and the independent factors affecting CSP efficacy were analyzed. RESULTS: The observation group had lower CSM, minimum sagittal muscle thickness and RI than the control group. CSM, RI, and minimum sagittal thickness in patients with type II CSP were lower than those in patients with type I, and these indicators in patients with type III were lower than those in patients with type II. The area under the curve (AUC) of CSM, RI and minimum sagittal muscle thickness in combination for CSP diagnosis and the AUC for CSP sub-types were higher than those of each indicator alone. Gestational sac size and CSM were independent factors affecting CSP treatment. CONCLUSION: Changes in TV-CDU parameters facilitates CSP diagnosis after cesarean section. CSM, minimum sagittal muscle thickness changes, and RI in combination possesses high value for CSP diagnosis and CSP sub-types. Gestational sac size and CSM are independent factors affecting CSP treatment.


Assuntos
Cesárea , Cicatriz , Ultrassonografia Doppler em Cores , Humanos , Feminino , Gravidez , Cesárea/efeitos adversos , Cicatriz/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Adulto , Gravidez Ectópica/diagnóstico por imagem , Gravidez Ectópica/cirurgia , Estudos de Casos e Controles , Útero/diagnóstico por imagem , Útero/irrigação sanguínea
9.
BMC Ophthalmol ; 24(1): 89, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413884

RESUMO

BACKGROUND: To evaluate the changes in retrobulbar circulation after strabismus surgery and to assess the relationship of these changes with choroidal thickness (CT). METHODS: This prospective study included 26 eyes of 26 patients who underwent strabismus surgery and 15 eyes of 15 healthy individuals as control group. The patients who had single horizontal muscle surgery were included in Group 1 (n = 14); and those who had surgery on both horizontal muscles were included in Group 2 (n = 12). Peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) of ophthalmic artery (OA), posterior ciliary artery (PCA), and central retinal artery (CRA) were measured using Color Doppler Ultrasonography. Subfoveal CT was measured via Optical Coherence Tomography. All measurements were obtained preoperatively, at 1st week and 1st month after surgery. RESULTS: There were no differences regarding preoperative blood flow velocity parameters among the groups. OA RI increased significantly at 1st week and 1st month after surgery in Group 1 and 2 (P = 0.029 and P = 0.045, respectively). There was a significant increase in PCA PSV at 1st week in Group 1 (P = 0.002). There was no difference between the mean preoperative and postoperative CT among the 3 groups. A negative correlation between the percentage changes of CT and CRA EDV was found in Group 2 (P = 0.011). CONCLUSION: Single and double horizontal rectus muscle surgery have a measurable effect on retrobulbar hemodynamics but these changes do not correlate with CT.


Assuntos
Artéria Retiniana , Estrabismo , Humanos , Estudos Prospectivos , Órbita , Hemodinâmica/fisiologia , Artéria Retiniana/diagnóstico por imagem , Artéria Oftálmica , Velocidade do Fluxo Sanguíneo/fisiologia , Corioide , Ultrassonografia Doppler em Cores/métodos , Estrabismo/cirurgia
10.
BMC Ophthalmol ; 24(1): 64, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350897

RESUMO

OBJECTIVE: To evaluate the alterations in retrobulbar color Doppler imaging (CDI) parameters and retinal/choroidal optical coherence tomography angiography (OCTA) parameters and their association with the clinical activity and severity in thyroid-associated orbitopathy (TAO) patients. METHODS: In this study, the retrobulbar flow parameters including resistance index (RI), Pulsatile Index(PI), peak systolic velocity (PSV) and end diastolic velocity (EDV) in posterior ciliary artery (PCA), central retinal artery (CRA) and ophthalmic artery (OA) were determined by CDI. Moreover, the retina and choroidal vascularity including the superficial vessel density (SVD), deep vessel density (DVD), choroidal thickness (ChT) and choroidal vascularity, including total choroidal area (TCA), luminal area (LA), stromal area (SA) and Choroidal Vascularity Index (CVI), were determined by OCTA. All patients grouped as active TAO and inactive TAO based on Clinical activity score (CAS). We picked the severe eye among the subjects and compared all parameters between two groups. We analyzed the correlations among those parameters. RESULTS: There was a significant difference in CAS score, proptosis value, ChT, LA, CVI between patients with active TAO and inactive TAO. In the active group, PSV and EDV of PCA were significantly higher than the inactive group. On logistic regression analysis, CAS was closely associated with PSV-PCA. On multiple linear regression, proptosis value was closely associated with ChT, LA, SA and CVI. CONCLUSION: Choroidal vascularization and retrobulbar blood flow were concurrently higher in active TAO patients and several variables in choroid circulation was closely related to TAO clinical features.


Assuntos
Oftalmopatia de Graves , Humanos , Estudos Transversais , Órbita/diagnóstico por imagem , Artéria Oftálmica/diagnóstico por imagem , Corioide , Ultrassonografia Doppler em Cores/métodos , Velocidade do Fluxo Sanguíneo/fisiologia
11.
J Ultrasound Med ; 43(6): 1045-1051, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38356337

RESUMO

OBJECTIVES: The aim of this study was to establish the relationship of facial artery with nasolabial fold by color Doppler sonography and to determine facial artery variations and their relationship with age, gender, or hemifaces. METHODS: The study included 188 patients (94 women, 94 men) aged 18-60 years. Overall, 376 facial arteries in both hemifaces were evaluated for the course within nasolabial fold, symmetry, and relationship with gender. RESULTS: The mean age of the patients was 39.29 ± 12.81 years. Type A (55.7%) was the most common type in both hemifaces. There was no significant relationship between the course of facial artery and age (P > .05). Asymmetrical course of facial artery was more common in females (54.3%). In both genders, type A was the type with highest symmetry detected. CONCLUSIONS: Nasolabial fold is one of the important facial regions for filler injection. To prevent vascular injection, course of facial artery should be identified within the nasolabial fold. Type A was the most common type in both hemifaces and genders. Although the rates were close to each other, asymmetry in the course of the facial artery was observed in most of the patients. Ultrasonographic examination which is non-invasive and non-ionizing imaging method can be performed carefully before filler injection to determine vascular tissues.


Assuntos
Artérias , Face , Sulco Nasogeniano , Ultrassonografia Doppler em Cores , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Adolescente , Sulco Nasogeniano/diagnóstico por imagem , Adulto Jovem , Face/irrigação sanguínea , Face/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Artérias/diagnóstico por imagem , Fatores Sexuais
12.
J Ultrasound Med ; 43(11): 2015-2025, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39101721

RESUMO

This systematic review evaluated accuracy of ureteric jet angles on color Doppler sonography in diagnosing vesico-ureteric reflux (VUR) in children, using voiding cystourethrogram as the reference standard. Six databases were searched, yielding 13 eligible studies of an initial 429, 7 with comparable data. Risk of bias and applicability were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Most studies demonstrated a correlation between increasing jet angle and VUR severity, but reporting and techniques varied, preventing meta-analysis. Ureteric jet angle sonography may have potential as a VUR triaging tool. Further investigations with rigorous methodology are required. Funding support was obtained from Queensland University of Technology. PROSPERO Registration CRD42020159799.


Assuntos
Ultrassonografia Doppler em Cores , Ureter , Refluxo Vesicoureteral , Humanos , Refluxo Vesicoureteral/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Criança , Ureter/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Ultrasound Med ; 43(9): 1605-1610, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38747480

RESUMO

OBJECTIVES: To detect ultrasonographic anatomical alterations in all the skin layers in patients with vitiligo. METHODS: A prospective observational color Doppler ultrasound study was performed in nonsegmental face and/or neck vitiligo patients without a history of previous treatments. Two sites, a lesional area and a contralateral clinically healthy region, were ultrasonographically studied and compared in the same patient. All cases were studied in high-frequency (24 MHz) and ultra-high-frequency (70 MHz) ultrasound devices with the highest axial spatial resolution available in the market. Demographic data of the sample, ultrasound grayscale, and color Doppler features were recorded and analyzed. RESULTS: Ten patients met the study criteria (60% females; mean age 49 years). All cases presented ultrasonographic undulation of the epidermis in the affected zones vs 50% in the healthy control regions, being more prominent in the vitiligo areas. Eighty percent demonstrated intense hypoechoic thin plaques in the upper dermis (subepidermal). All vitiligo areas presented thickening and hypoechogenicity of the regional hair follicles and/or pilosebaceous units. Ninety percent showed prominent sebaceous glands, and 20% demonstrated a hypoechoic cap surrounding the sebaceous glands in the lesional areas. Dermal hypervascularity was detected in 100% of the affected regions and 40% of the clinically healthy areas. CONCLUSION: Ultrasound can identify subclinical inflammatory cutaneous patterns in the epidermis, dermis, hair follicles, pilosebaceous units, and sebaceous glands in vitiligo. This noninvasive information can support early detection, monitoring, and research, including the clinical trials of drugs used to manage this devastating disease.


Assuntos
Ultrassonografia Doppler em Cores , Vitiligo , Humanos , Vitiligo/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia Doppler em Cores/métodos , Adulto , Pele/diagnóstico por imagem , Idoso , Face/diagnóstico por imagem , Adulto Jovem
14.
J Ultrasound Med ; 43(8): 1375-1388, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38581195

RESUMO

OBJECTIVES: Our study aims to investigate the impact of B-mode ultrasound (B-US) imaging, color Doppler flow imaging (CDFI), strain elastography (SE), and patient age on the prediction of molecular subtypes in breast lesions. METHODS: Totally 2272 multimodal ultrasound imaging was collected from 198 patients. The ResNet-18 network was employed to predict four molecular subtypes from B-US imaging, CDFI, and SE of patients with different ages. All the images were split into training and testing datasets by the ratio of 80%:20%. The predictive performance on testing dataset was evaluated through 5 metrics including mean accuracy, precision, recall, F1-scores, and confusion matrix. RESULTS: Based on B-US imaging, the test mean accuracy is 74.50%, the precision is 74.84%, the recall is 72.48%, and the F1-scores is 0.73. By combining B-US imaging with CDFI, the results were increased to 85.41%, 85.03%, 85.05%, and 0.84, respectively. With the integration of B-US imaging and SE, the results were changed to 75.64%, 74.69%, 73.86%, and 0.74, respectively. Using images from patients under 40 years old, the results were 90.48%, 90.88%, 88.47%, and 0.89. When images from patients who are above 40 years old, they were changed to 81.96%, 83.12%, 80.5%, and 0.81, respectively. CONCLUSION: Multimodal ultrasound imaging can be used to accurately predict the molecular subtypes of breast lesions. In addition to B-US imaging, CDFI rather than SE contribute further to improve predictive performance. The predictive performance is notably better for patients under 40 years old compared with those who are 40 years old and above.


Assuntos
Neoplasias da Mama , Mama , Aprendizado Profundo , Técnicas de Imagem por Elasticidade , Ultrassonografia Mamária , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Ultrassonografia Mamária/métodos , Técnicas de Imagem por Elasticidade/métodos , Fatores Etários , Idoso , Mama/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Adulto Jovem , Valor Preditivo dos Testes , Algoritmos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Idoso de 80 Anos ou mais
15.
J Ultrasound Med ; 43(9): 1695-1709, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38837497

RESUMO

OBJECTIVE: This study aimed to validate the efficiency of Doppler ultrasonography for predicting the innominate, subclavian, and common carotid artery stenosis. METHODS: This retrospective multicenter study between 2013 and 2022 enrolled 636 patients who underwent carotid Doppler ultrasonography and subsequent digital subtraction angiography. And 58 innominate artery stenosis, 147 common carotid artery stenosis, and 154 subclavian artery stenosis were included. The peak systolic velocity at innominate, subclavian, and common carotid artery, and velocity ratios of innominate artery to common carotid artery, innominate artery to subclavian artery, and common carotid artery to internal carotid artery were measured or calculated. The threshold values were determined using receiver operating characteristic analysis. RESULTS: The threshold values of innominate artery stenosis were peak systolic velocity >206 cm/s (sensitivity: 82.8%; specificity: 91.4%) to predict ≥50% stenosis and >285 cm/s (sensitivity: 89.2%; specificity: 94.9%) to predict ≥70% stenosis. The threshold values of common carotid artery stenosis were peak systolic velocity >175 cm/s (sensitivity: 78.2%; specificity: 91.9%) to predict ≥50% stenosis and >255 cm/s (sensitivity: 87.1%; specificity: 87.2%) to predict ≥70% stenosis. The threshold values of subclavian artery stenosis were peak systolic velocity >200 cm/s (sensitivity: 68.2%; specificity: 84.4%) to predict ≥50% stenosis and >305 cm/s (sensitivity: 57.9%; specificity: 91.4%) to predict ≥70% stenosis. CONCLUSIONS: Symptomatic patients with ultrasonic parameters of velocity at innominate artery ≥206 cm/s, velocity at common carotid artery ≥175 cm/s, or velocity at subclavian artery ≥200 cm/s need to be considered for further verification and whether revascularization is necessary.


Assuntos
Tronco Braquiocefálico , Artéria Carótida Primitiva , Estenose das Carótidas , Sensibilidade e Especificidade , Artéria Subclávia , Ultrassonografia Doppler em Cores , Humanos , Feminino , Masculino , Estudos Retrospectivos , Tronco Braquiocefálico/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Pessoa de Meia-Idade , Idoso , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiopatologia , Ultrassonografia Doppler em Cores/métodos , Reprodutibilidade dos Testes
16.
Altern Ther Health Med ; 30(10): 188-194, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38330565

RESUMO

Objective: The goal of this study was to explore the application effect of preoperative computed tomography (CT) angiography and color ultrasound-assisted design of lower limb perforator flaps in the repair of lower limb soft tissue defects. Repair of soft tissue defects in the lower limbs is a challenging surgical task, and accurate preoperative location of vascular structures and detailed design of the surgical plan are crucial to the success of the surgery. This study aims to improve the accuracy and effectiveness of lower limb perforator flap repair surgery by introducing CT angiography and color ultrasound technology. Methods: Sixty-four patients who underwent lower limb soft tissue defect repair with perforator flaps were enrolled at our hospital from February 2020 to February 2023. According to their admission time, they were divided into two groups: 32 patients admitted before June 31, 2022, were included in the control group, and preoperative color Doppler ultrasound was used to assist in designing the lower limb perforator flap; 32 patients admitted after June 31, 2022, were included in the study group, and preoperative CT angiography and color Doppler ultrasound were used to assist in designing the lower limb perforator flap. Specifically, we conducted detailed records and analyzes of patients' age distribution, gender ratio, and relevant medical history. This demographic information will help reveal whether there are differences in the effectiveness of preoperative CT angiography and color ultrasound-assisted lower extremity perforator flap design among different patient groups. By considering these key factors, we can more accurately assess the actual utility of new technologies in different patient groups and provide more specific guidance for clinical practice.The therapeutic effects of the two groups of patients were recorded. The differences between the preoperative CT angiography measurements and intraoperative actual measurements of the study group were compared. Clinical indicators, sensory function in the graft area, flap survival rate, flap complication rate, and donor area complication rate were compared between the two groups. The satisfaction of patients in the two groups with the recovery of the surgical area was also compared. Results: The treatment success rate of the study group was higher than that of the control group (P < .05). There was no significant difference in the preoperative CT angiography measurements (shallow branch localization, shallow branch starting diameter, shallow branch length, deep branch starting diameter) and intraoperative actual measurements of the study group (P > .05). The operation time and intraoperative blood loss of the study group were shorter than those of the control group (P < .05), and there was no significant difference in flap harvesting area and length of hospital stay between the two groups (P > .05). There was a difference in sensory function in the graft area between the two groups, with a higher proportion of S4 grade in the study group and better recovery compared to the control group (P < .05). There was no significant difference in satisfaction evaluation between the two groups (P > .05). Conclusion: Preoperative CT angiography and color ultrasound-assisted design of lower limb perforator flaps have shown significant clinical advantages in repairing lower limb soft tissue defects, improving treatment effects and surgical efficiency. In clinical practice, this technology is expected to reduce surgical complexity, shorten surgical time, reduce the risk of intraoperative bleeding, and achieve effective defect repair while maintaining or improving the patient's sensory function.However, there are some limitations to the study, such as the relatively small sample size and single-center nature. Future research can optimize the operation process of this technology, expand the scope of research, and explore its application in the repair of soft tissue defects caused by specific causes. This technology may provide more precise and effective options for personalized treatment, especially for patients who need to preserve more sensory function.


Assuntos
Angiografia por Tomografia Computadorizada , Extremidade Inferior , Retalho Perfurante , Lesões dos Tecidos Moles , Humanos , Masculino , Feminino , Retalho Perfurante/irrigação sanguínea , Angiografia por Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Adulto , Extremidade Inferior/cirurgia , Extremidade Inferior/irrigação sanguínea , Lesões dos Tecidos Moles/cirurgia , Lesões dos Tecidos Moles/diagnóstico por imagem , Idoso , Ultrassonografia Doppler em Cores/métodos , Procedimentos de Cirurgia Plástica/métodos , Cuidados Pré-Operatórios/métodos
17.
J Appl Clin Med Phys ; 25(3): e14298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38373294

RESUMO

PURPOSE: Diagnosing Renal artery stenosis (RAS) presents challenges. This research aimed to develop a deep learning model for the computer-aided diagnosis of RAS, utilizing multimodal fusion technology based on ultrasound scanning images, spectral waveforms, and clinical information. METHODS: A total of 1485 patients received renal artery ultrasonography from Peking Union Medical College Hospital were included and their color doppler sonography (CDS) images were classified according to anatomical site and left-right orientation. The RAS diagnosis was modeled as a process involving feature extraction and multimodal fusion. Three deep learning (DL) models (ResNeSt, ResNet, and XCiT) were trained on a multimodal dataset consisted of CDS images, spectrum waveform images, and individual basic information. Predicted performance of different models were compared with senior physician and evaluated on a test dataset (N = 117 patients) with renal artery angiography results. RESULTS: Sample sizes of training and validation datasets were 3292 and 169 respectively. On test data (N = 676 samples), predicted accuracies of three DL models were more than 80% and the ResNeSt achieved the accuracy 83.49% ± 0.45%, precision 81.89% ± 3.00%, and recall 76.97% ± 3.7%. There was no significant difference between the accuracy of ResNeSt and ResNet (82.84% ± 1.52%), and the ResNeSt was higher than the XCiT (80.71% ± 2.23%, p < 0.05). Compared to the gold standard, renal artery angiography, the accuracy of ResNest model was 78.25% ± 1.62%, which was inferior to the senior physician (90.09%). Besides, compared to the multimodal fusion model, the performance of single-modal model on spectrum waveform images was relatively lower. CONCLUSION: The DL multimodal fusion model shows promising results in assisting RAS diagnosis.


Assuntos
Aprendizado Profundo , Obstrução da Artéria Renal , Humanos , Obstrução da Artéria Renal/diagnóstico por imagem , Angiografia , Ultrassonografia Doppler em Cores/métodos
18.
J Clin Ultrasound ; 52(8): 1166-1167, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39082283

RESUMO

MV-Flow is a tool enables to acquire spatially and temporally coherent data on low-speed blood flow information. In our case, it allowed a better definition of vein of Galen aneurysmal malformation morphology, venous drainage and feeder vessels than standard ultrasound techniques.


Assuntos
Ultrassonografia Pré-Natal , Malformações da Veia de Galeno , Humanos , Malformações da Veia de Galeno/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Feminino , Gravidez , Adulto , Veias Cerebrais/diagnóstico por imagem , Veias Cerebrais/anormalidades , Ultrassonografia Doppler em Cores/métodos
19.
J Clin Ultrasound ; 52(6): 809-812, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597286

RESUMO

Primary ovarian carcinoid (POC) is a very rare subset of ovarian tumors, presenting diagnostic challenges due to its inconclusive radiological imaging. In this case study, we present a 30-year-old nulliparous female with subfertility complaints and irregular menstrual cycles, who was initially misdiagnosed with an ovarian cyst. Subsequent comprehensive imaging, including Color Doppler, revealed high vascularity, and prompting suspicion of malignancy. Surgical resection and histopathological evaluation ultimately confirmed the presence of a rare Carcinoid tumor, insular type. This case emphasizes a multidisciplinary approach to the early detection and accurate diagnosis of POCs.


Assuntos
Tumor Carcinoide , Neoplasias Ovarianas , Humanos , Feminino , Tumor Carcinoide/diagnóstico por imagem , Neoplasias Ovarianas/diagnóstico por imagem , Adulto , Diagnóstico Diferencial , Ultrassonografia Doppler em Cores/métodos , Ovário/diagnóstico por imagem
20.
J Clin Ultrasound ; 52(4): 442-444, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38407455

RESUMO

We describe a rare case of Mondor disease of the superficial scrotal veins, which can clinically mimic acute testicular pathologies such as testicular torsion or epididymo-orchitis, and highlight the value of grayscale/Doppler ultrasound examination in distinguishing these entities, which have different management implications.


Assuntos
Escroto , Humanos , Masculino , Escroto/diagnóstico por imagem , Escroto/irrigação sanguínea , Diagnóstico Diferencial , Torção do Cordão Espermático/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Orquite/diagnóstico por imagem , Doença Aguda , Adulto , Veias/diagnóstico por imagem , Emergências , Ultrassonografia Doppler/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA