Your browser doesn't support javascript.
loading
Microanastomosis venosa mecánica coupler®: un importante aporte tecnológico a la microcirugía vascular / Coupler® venous mechanic microanastomosis: an important technological contribution to microvascular surgery
Andrades C., Patricio; Calderón G., María Elsa; Danilla E., Stefan; Erazo C., Cristian; Benítez S., Susana; Sepúlveda P., Sergio.
Affiliation
  • Andrades C., Patricio; Universidad de Chile. Hospital Clínico. Departamento de Cirugía. Santiago. CL
  • Calderón G., María Elsa; Universidad de Chile. Hospital Clínico. Departamento de Cirugía. Santiago. CL
  • Danilla E., Stefan; Universidad de Chile. Hospital Clínico. Departamento de Cirugía. Santiago. CL
  • Erazo C., Cristian; Universidad de Chile. Hospital Clínico. Departamento de Cirugía. Santiago. CL
  • Benítez S., Susana; Universidad de Chile. Hospital Clínico. Departamento de Cirugía. Santiago. CL
  • Sepúlveda P., Sergio; Universidad de Chile. Hospital Clínico. Departamento de Cirugía. Santiago. CL
Rev. chil. cir ; 66(1): 52-58, feb. 2014. ilus, tab
Article in Es | LILACS | ID: lil-705552
Responsible library: CL1.1
RESUMEN

Objetivo:

El objetivo del presente trabajo es dar a conocer la experiencia de nuestro grupo de Cirugía Plástica, en sutura mecánica microvascular utilizando el dispositivo Coupler® (Synovis Corp, Birmingham, AL) para las anastomosis venosas realizadas en pacientes sometidos microcirugía reconstructiva. Material y

Método:

Revisión retrospectiva de los últimos 48 colgajos libres operados entre marzo de 2009 y febrero de 2013. Todas las anastomosis microquirúrgicas venosas fueron realizadas con el dispositivo Coupler® y las anastomosis arteriales con sutura separada o continua de nylon 9-0 ó 10-0. Los datos recolectados fueron datos personales y médicos del paciente, localización del defecto, colgajo utilizado, diámetro de los vasos, anastomosis arterial, Coupler® utilizado, tiempo de anastomosis, complicaciones postoperatorias, trombosis arterial y trombosis venosa.

Resultados:

Fueron realizados 48 colgajos libres para reconstrucción de extremidad inferior (n = 25, 52,1 por ciento); cabeza-cuello (n = 15, 31 por ciento); mama (n = 5, 10,4 por ciento) y extremidad superior (n = 3, 6,3 por ciento). Los colgajos utilizados fueron Anterolateral de muslo o ALT (n = 25, 52,1 por ciento), Radial (n = 10, 20,8 por ciento), Perforante de Arteria Epigástrica Inferior o DIEP (n = 5, 10,4 por ciento), Dorsal Ancho (n = 2, 4,2 por ciento), Recto Abdominal (n = 2, 4,2 por ciento), Fíbula (n = 2, 4,2 por ciento), Escápula (n = 1, 2,1), y Gracilis (n = 1, 2,1 por ciento). El diámetro promedio del dispositivo Coupler® utilizado en el total de los casos fue de 2,51 +/- 0,46 mm. El tiempo promedio para la anastomosis venosa fue de 13,5 +/- 7,3 min. Un total de 4 colgajos se perdieron (8,3 por ciento), ninguno a causa de falla venosa.

Conclusiones:

El Coupler® venoso es un elemento seguro, efectivo y rápido para la realización de las anastomosis microquirúrgicas, es fácil de aprender y su implementación debiese ser considerada en todo centro donde se realice microcirugía.
ABSTRACT

Aim:

The aim of the present paper is to show the experience of the Plastic Surgery Division at the University of Chile Clinical Hospital, with the Coupler® anastomotic device (Synovis Corp, Birmingham, AL) for venous microanastomoses in patients undergoing reconstructive microsurgery. Material and

Methods:

A retrospective review of 48 consecutive patients with free flaps between March 2009 and in February 2013. All microsurgical venous anastomoses were performed with the Coupler® device and the arterial anastomoses with interrupted or continuous 9-0 or 10-0 nylon sutures. The collected data were personal and medical patient information, location of the defect, flap used, vessels diameter, arterial anastomoses, Coupler® used, time of anastomosis, postoperative complications, arterial and venous thrombosis.

Results:

A total of 48 free flaps were performed for reconstruction of lower extremity (n = 25, 52.1%); head-neck (n = 15, 31%); breast (n = 5, 10.4%) and upper extremity (n = 3, 6.3%). The flaps used were Anterolateral thigh or ALT (n = 25, 52.1%), Radial (n = 10, 20.8%), Deep Inferior Epigastric Artery Perforator or DIEP (n = 5, 10.4%), Latisimus Dorsi (n = 2, 4.2%), Rectus Abdominus (n = 2, 4.2%), Fibula (n = 2, 4.2%), Scapula (n = 1, 2.1%), and Gracilis (n = 1, 2.1%). The Coupler device average diameter used was 2.51 ± 0.46 mm. The average time for the venous anastomosis was 13.5 ± 7.3 minutes. A total of 4 flaps were lost (8.3%), none due to venous thrombosis.

Conclusions:

The Coupler® System for venous anastomoses is a safe, effective and quick method for microsurgical anastomoses, it is easy to learn and its implementation should be considered in every microvascular surgery center.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: LILACS Main subject: Surgical Flaps / Vascular Surgical Procedures / Anastomosis, Surgical / Microsurgery Type of study: Observational_studies Limits: Adult / Female / Humans / Male Language: Es Journal: Rev. chil. cir Journal subject: CIRURGIA GERAL Year: 2014 Type: Article Affiliation country: Chile

Full text: 1 Collection: 01-internacional Database: LILACS Main subject: Surgical Flaps / Vascular Surgical Procedures / Anastomosis, Surgical / Microsurgery Type of study: Observational_studies Limits: Adult / Female / Humans / Male Language: Es Journal: Rev. chil. cir Journal subject: CIRURGIA GERAL Year: 2014 Type: Article Affiliation country: Chile