Microanastomosis venosa mecánica coupler®: un importante aporte tecnológico a la microcirugía vascular / Coupler® venous mechanic microanastomosis: an important technological contribution to microvascular surgery
Rev. chil. cir
; 66(1): 52-58, feb. 2014. ilus, tab
Article
in Es
| LILACS
| ID: lil-705552
Responsible library:
CL1.1
RESUMEN
Objetivo:
El objetivo del presente trabajo es dar a conocer la experiencia de nuestro grupo de Cirugía Plástica, en sutura mecánica microvascular utilizando el dispositivo Coupler® (Synovis Corp, Birmingham, AL) para las anastomosis venosas realizadas en pacientes sometidos microcirugía reconstructiva. Material yMétodo:
Revisión retrospectiva de los últimos 48 colgajos libres operados entre marzo de 2009 y febrero de 2013. Todas las anastomosis microquirúrgicas venosas fueron realizadas con el dispositivo Coupler® y las anastomosis arteriales con sutura separada o continua de nylon 9-0 ó 10-0. Los datos recolectados fueron datos personales y médicos del paciente, localización del defecto, colgajo utilizado, diámetro de los vasos, anastomosis arterial, Coupler® utilizado, tiempo de anastomosis, complicaciones postoperatorias, trombosis arterial y trombosis venosa.Resultados:
Fueron realizados 48 colgajos libres para reconstrucción de extremidad inferior (n = 25, 52,1 por ciento); cabeza-cuello (n = 15, 31 por ciento); mama (n = 5, 10,4 por ciento) y extremidad superior (n = 3, 6,3 por ciento). Los colgajos utilizados fueron Anterolateral de muslo o ALT (n = 25, 52,1 por ciento), Radial (n = 10, 20,8 por ciento), Perforante de Arteria Epigástrica Inferior o DIEP (n = 5, 10,4 por ciento), Dorsal Ancho (n = 2, 4,2 por ciento), Recto Abdominal (n = 2, 4,2 por ciento), Fíbula (n = 2, 4,2 por ciento), Escápula (n = 1, 2,1), y Gracilis (n = 1, 2,1 por ciento). El diámetro promedio del dispositivo Coupler® utilizado en el total de los casos fue de 2,51 +/- 0,46 mm. El tiempo promedio para la anastomosis venosa fue de 13,5 +/- 7,3 min. Un total de 4 colgajos se perdieron (8,3 por ciento), ninguno a causa de falla venosa.Conclusiones:
El Coupler® venoso es un elemento seguro, efectivo y rápido para la realización de las anastomosis microquirúrgicas, es fácil de aprender y su implementación debiese ser considerada en todo centro donde se realice microcirugía.ABSTRACT
Aim:
The aim of the present paper is to show the experience of the Plastic Surgery Division at the University of Chile Clinical Hospital, with the Coupler® anastomotic device (Synovis Corp, Birmingham, AL) for venous microanastomoses in patients undergoing reconstructive microsurgery. Material andMethods:
A retrospective review of 48 consecutive patients with free flaps between March 2009 and in February 2013. All microsurgical venous anastomoses were performed with the Coupler® device and the arterial anastomoses with interrupted or continuous 9-0 or 10-0 nylon sutures. The collected data were personal and medical patient information, location of the defect, flap used, vessels diameter, arterial anastomoses, Coupler® used, time of anastomosis, postoperative complications, arterial and venous thrombosis.Results:
A total of 48 free flaps were performed for reconstruction of lower extremity (n = 25, 52.1%); head-neck (n = 15, 31%); breast (n = 5, 10.4%) and upper extremity (n = 3, 6.3%). The flaps used were Anterolateral thigh or ALT (n = 25, 52.1%), Radial (n = 10, 20.8%), Deep Inferior Epigastric Artery Perforator or DIEP (n = 5, 10.4%), Latisimus Dorsi (n = 2, 4.2%), Rectus Abdominus (n = 2, 4.2%), Fibula (n = 2, 4.2%), Scapula (n = 1, 2.1%), and Gracilis (n = 1, 2.1%). The Coupler device average diameter used was 2.51 ± 0.46 mm. The average time for the venous anastomosis was 13.5 ± 7.3 minutes. A total of 4 flaps were lost (8.3%), none due to venous thrombosis.Conclusions:
The Coupler® System for venous anastomoses is a safe, effective and quick method for microsurgical anastomoses, it is easy to learn and its implementation should be considered in every microvascular surgery center.Key words
Full text:
1
Collection:
01-internacional
Database:
LILACS
Main subject:
Surgical Flaps
/
Vascular Surgical Procedures
/
Anastomosis, Surgical
/
Microsurgery
Type of study:
Observational_studies
Limits:
Adult
/
Female
/
Humans
/
Male
Language:
Es
Journal:
Rev. chil. cir
Journal subject:
CIRURGIA GERAL
Year:
2014
Type:
Article
Affiliation country:
Chile