Development of a high-performance liquid chromatographic method for the quantification of chlorpyrifos, pyridostigmine bromide, N,N-diethyl-m-toluamide and their metabolites in rat plasma and urine.
Abu-Qare, A W; Abou-Donia, M B.
Affiliation
  • Abu-Qare AW; Department of Pharmacology and Cancer Biology, Duke University Medical Center, Durham, NC 27710, USA.
J Chromatogr B Biomed Sci Appl ; 754(2): 533-8, 2001 Apr 25.
Article in En | MEDLINE | ID: mdl-11339298
ABSTRACT
A method was developed for the separation and quantification of the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate), its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate) and TCP (3,5,6-trichloro-2-pyridinol), the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide), its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), and its metabolites m-toluamide and m-toluic acid in rat plasma and urine. The method is based on using solid-phase extraction and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 210 and 280 nm. The compounds were separated using a gradient of 1-85% acetonitrile in water (pH 3.20) at a flow-rate ranging between 1 and 1.7 ml/min over a period of 15 min. The retention times ranged from 5.4 to 13.2 min. The limits of detection ranged between 20 and 150 ng/ml, while the limits of quantitation were between 150 and 200 ng/ml. Average percentage recovery of five spiked plasma samples was 80.2+/-7.9, 74.9+/-8.5, 81.7+/-6.9, 73.1+/-7.8, 74.3+/-8.3, 80.8+/-6.6, 81.6+/-7.3 and 81.4+/-6.5, and from urine 79.4+/-6.9, 77.8+/-8.4, 83.3+/-6.6, 72.8+/-9.0, 76.3+/-7.7, 83.4+/-7.9, 81.6+/-7.9 and 81.8+/-6.8 for chlorpyrifos, chlorpyrifos-oxon, TCP, pyridostigmine bromide, N-methyl-3-hydroxypyridinium bromide, DEET, m-toluamide and m-toluic acid, respectively. The relationship between peak areas and concentration was linear over a range between 200 and 2000 ng/ml.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Pyridostigmine Bromide / Chromatography, High Pressure Liquid / DEET / Chlorpyrifos Limits: Animals Language: En Journal: J Chromatogr B Biomed Sci Appl Journal subject: QUIMICA CLINICA Year: 2001 Type: Article Affiliation country: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Pyridostigmine Bromide / Chromatography, High Pressure Liquid / DEET / Chlorpyrifos Limits: Animals Language: En Journal: J Chromatogr B Biomed Sci Appl Journal subject: QUIMICA CLINICA Year: 2001 Type: Article Affiliation country: United States