Your browser doesn't support javascript.
loading
[Application of liquid chip-mass spectrometry technology for screening serum biomarker proteins in lung squamous cell carcinoma].
Bu, Li-Na; Yang, Shuan-Ying; Du, Jie; Nan, Yan-Dong; Lin, Xiu-Li; Zheng, Hua-Dong; Huo, Shu-Fen; Shang, Wen-Li; Liu, Yan-Feng.
Affiliation
  • Bu LN; Department of Respiratory Medicine, Second Affiliated Hospital of Medical School, Xi'an Jiaotong University, Xi'an 710004, China.
Zhonghua Yi Xue Za Zhi ; 89(24): 1662-6, 2009 Jun 23.
Article in Zh | MEDLINE | ID: mdl-19957521
OBJECTIVE: To screen the serum biomarker proteins of lung squamous cell carcinoma (SCCs) by liquid chip-mass spectrometry technology. METHODS: All serum samples, including 34 SCCs, 46 benign lung diseases (BLDs) and 44 healthy individuals, were analyzed by CLINPROT system in order to study the serum protein expression profiles. Then the discriminatory proteins were detected by FlexAnalysis 3.0 software. Biomarkers were identified by liquid chromatography-tandem mass spectrometry (LCMS/MS). RESULTS: Comparing the differential serum expression proteins between SCCs and healthy individuals, and SCCs and BLDs respectively. Ninety-six differential protein peaks [mass-to-charge ration (M/Z) between 800 and 10 000] were found between SCCs and healthy individuals. In these protein peaks, the expression of protein peaks at 4054.13 M/Z and 4267.46 M/Z had the largest difference between them. The two protein peaks could accurately separate SCCs from healthy individuals by the frame of axes. Similarly, 99 differential protein peaks were automatically detected between SCCs and BLDs. In these protein peaks, the expression of protein peaks at 5065.27 M/Z and 4054.02 M/Z had the largest difference between them. The two protein peaks could accurately separate SCCs from BLDs by the frame of axes. Identified by LC-MS/MS, 1778 M/Z and 1865 M/Z might be assayed jointly and corresponded to complements C3 fragment or C3f precursor. CONCLUSIONS: Differential protein expressions existed between SCCs versus healthy individuals and SCCs versus BLD patients. It is feasible to screen the diagnostic serum biomarkers of SCC with a high sensitivity and specificity by using CLINPROT system.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Squamous Cell / Biomarkers, Tumor / Lung Neoplasms Type of study: Diagnostic_studies / Observational_studies / Screening_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: Zh Journal: Zhonghua Yi Xue Za Zhi Year: 2009 Type: Article Affiliation country: China
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Squamous Cell / Biomarkers, Tumor / Lung Neoplasms Type of study: Diagnostic_studies / Observational_studies / Screening_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: Zh Journal: Zhonghua Yi Xue Za Zhi Year: 2009 Type: Article Affiliation country: China