Photoscreeners in the pediatric eye office: compared testability and refractions on high-risk children.
Peterseim, Mae Millicent W; Papa, Carrie E; Wilson, M Edward; Cheeseman, Edward W; Wolf, Bethany J; Davidson, Jennifer D; Trivedi, Rupal H.
Affiliation
  • Peterseim MM; Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina. Electronic address: petersem@musc.edu.
  • Papa CE; Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina.
  • Wilson ME; Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina.
  • Cheeseman EW; Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina.
  • Wolf BJ; Department of Public Health Sciences, Medical University of South Carolina, Charleston, South Carolina.
  • Davidson JD; Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina.
  • Trivedi RH; Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina.
Am J Ophthalmol ; 158(5): 932-8, 2014 Nov.
Article in En | MEDLINE | ID: mdl-25089352
PURPOSE: To compare refractive data and testability of Spot (PediaVision) and Plusoptix A09 (Plusoptix, Inc) photoscreeners and to compare each device with traditional cycloplegic retinoscopy. DESIGN: Prospective, interventional case series. METHODS: After informed consent, patients underwent testing with the Spot and Plusoptix photoscreeners before their examination by a pediatric ophthalmologist masked to the results. Data including testability and estimated refractions were entered into a Research Electronic Data Capture database for statistical analysis. RESULTS: A total of 265 children were enrolled (mean age, 6.0 ± 3.4 years). Both devices produced a computer printout result in 250 (94.3%) of the patients. The Spot photoscreener provided a refractive estimate in all computer printouts, whereas the Plusoptix, used binocularly, provided a refractive estimate in 75.2% (188/250) of the printouts. Compared with cycloplegic retinoscopy, both devices underestimated hyperopia or overestimated myopia (-1.35 diopters [D] and -0.64 D, Spot and Plusoptix, respectively) and overestimated astigmatism (0.36 D and 0.32 D, Spot and Plusoptix, respectively). The intraclass correlation coefficient for spherical equivalents indicated good agreement between cycloplegic retinoscopy and Spot (0.806) and excellent agreement between cycloplegic retinoscopy and Plusoptix (0.898). CONCLUSIONS: The Spot photoscreener provided refractive data on a greater percentage of children. The photorefractors correlated with cycloplegic retinoscopy refractive findings for sphere and spherical equivalents, but underestimated hyperopia or overestimated myopia and overestimated astigmatism. The binocular refractions of Plusoptix agreed more closely with the refractions of our pediatric ophthalmologists.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Refraction, Ocular / Refractive Errors / Vision Screening Type of study: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Language: En Journal: Am J Ophthalmol Year: 2014 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Refraction, Ocular / Refractive Errors / Vision Screening Type of study: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Language: En Journal: Am J Ophthalmol Year: 2014 Type: Article