Your browser doesn't support javascript.
loading
The resistance of absorbable sutures in fetal tissue and fluids.
Turk J Pediatr ; 31(3): 209-14, 1989.
Article in En | MEDLINE | ID: mdl-2518585
ABSTRACT
The resistance of three different types of absorbable suture materials was studied in three groups which simulated intrauterine conditions. In group I the sutures were incubated in the amnioallantoic cavity of chicken embryo (CE) and in group II in the fetal tissue of CE. For incubation of sutures in group III, human amniotic fluid collected during cesarean section operations in the thirty-eighth week of pregnancy was used. We discovered that chromic catgut had a lower resistance in fetal tissue than in fetal fluid (p less than 0.01), which could be an important point in the selection of fetal dermal sutures. In vitro incubation in human amniotic fluid did not effect the known rate of loss of chromic catgut, proglactin 910 and polydioxanone.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Sutures / Fetus Type of study: Diagnostic_studies / Evaluation_studies Limits: Animals Language: En Journal: Turk J Pediatr Year: 1989 Type: Article
Search on Google