Your browser doesn't support javascript.
loading
Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation.
Imamura, Teruhiko; Kinugawa, Koichiro; Fujino, Takeo; Inaba, Toshiro; Maki, Hisataka; Hatano, Masaru; Kinoshita, Osamu; Nawata, Kan; Kyo, Shunei; Ono, Minoru.
Affiliation
  • Imamura T; Department of Therapeutic Strategy for Heart Failure, Graduate School of Medicine, University of Tokyo.
Circ J ; 79(1): 104-11, 2015.
Article in En | MEDLINE | ID: mdl-25381791
ABSTRACT

BACKGROUND:

Predicting the occurrence of aortic insufficiency (AI) during left ventricular assist device (LVAD) support has remained unsolved. METHODS AND

RESULTS:

We enrolled 52 patients who had received continuous flow LVAD (14 axial and 38 centrifugal pumps) and who been followed for ≥6 months between Jun 2006 and Dec 2013. Native aortic valve (AV) opening was observed in 18 patients (35%) with improved LV systolic function, and none of them had AI. On multivariate logistic regression analysis preoperative shorter heart failure duration was the only independent predictor of postoperative native AV opening (P=0.042; odds ratio [OR], 0.999). Of the remaining 34 patients (65%) with closed AV, 11 had AI with enlargement of the aortic root and narrow pulse pressure. Among those with closed AV, axial pump use (n=13) was the only significant predictor of the development of AI (P=0.042; OR, 4.950). Patients with AI had lower exercise capacity and a higher readmission rate than those without AI during 2-year LVAD support (55% vs. 8%; P<0.001).

CONCLUSIONS:

Native AV opening during LVAD support is profoundly associated with reversal of LV systolic function, especially in patients with preoperative shorter heart failure duration. Among those in whom the native AV remains closed, low pulsatility of axial flow pump may facilitate aortic root remodeling and post-LVAD AI development that results in worse clinical outcome.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve / Aortic Valve Insufficiency / Postoperative Complications / Heart-Assist Devices / Ventricular Dysfunction, Left / Heart Failure Type of study: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Circ J Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2015 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve / Aortic Valve Insufficiency / Postoperative Complications / Heart-Assist Devices / Ventricular Dysfunction, Left / Heart Failure Type of study: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Circ J Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2015 Type: Article