Your browser doesn't support javascript.
loading
A novel shortened electrospun nanofiber modified with a 'concentrated' polymer brush.
Yoshikawa, Chiaki; Zhang, Kun; Zawadzak, Ewelina; Kobayashi, Hisatoshi.
Affiliation
  • Yoshikawa C; World Premier International Center for Materials Nanoarchitectonics, National Institute for Materials Science, Tsukuba, Ibaraki 305-0044, Japan.
  • Zhang K; World Premier International Center for Materials Nanoarchitectonics, National Institute for Materials Science, Tsukuba, Ibaraki 305-0044, Japan.
  • Zawadzak E; World Premier International Center for Materials Nanoarchitectonics, National Institute for Materials Science, Tsukuba, Ibaraki 305-0044, Japan.
  • Kobayashi H; Bomaterials Center, National Institute for Materials Science, Tsukuba, Ibaraki 305-0047, Japan; CREST, JST, Sanbancho, Chiyoda, Tokyo 102-0075, Japan.
Sci Technol Adv Mater ; 12(1): 015003, 2011 Feb.
Article in En | MEDLINE | ID: mdl-27877380
ABSTRACT
We report the fabrication of shortened electrospun polymer fibers with a well-defined concentrated polymer brush. We first prepared electrospun nanofibers from a random copolymer of styrene and 4-vinylbenzyl 2-bromopropionate, with number-average molecular weight Mn=105 200 and weight-average molecular weight Mw=296 700 (Mw/Mn=2.82). The fibers had a diameter of 593±74 nm and contained initiating sites for surface-initiated atom transfer radical polymerization (SI-ATRP). Then, SI-ATRP of hydrophilic styrene sodium sulfonate (SSNa) was carried out in the presence of a free initiator and the hydrophobic fibers. Gel permeation chromatography confirmed that Mn and Mw/Mn values were almost the same for free polymers and graft polymers. Mn agreed well with the theoretical prediction, and Mw/Mn was relatively low (<1.3) in all the examined cases, indicating that this polymerization proceeded in a living manner. Using the values of the graft amount measured by Fourier transform infrared spectroscopy, the surface area, and Mn, we calculated the graft density σ as 0.22 chains nm-2. This value was nearly equal to the density obtained on silicon wafers (σ=0.24 chains nm-2), which is categorized into the concentrated brush regime. Finally, we mechanically cut the fibers with a concentrated poly(SSNa) brush by a homogenizer. With increasing cutting time, the fiber length became shorter and more homogenous (11±17 µm after 3 h). The shortened fibers exhibited excellent water dispersibility owing to the hydrophilic poly(SSNa) brush layer.