In the last 20 years, the role of ultrashort pulsed lasers in ophthalmology has become increasingly important. However, it is still impossible to guide ultra-short laser pulses with standard glass fibres. The highly energetic femtosecond pulses would destroy the fibre material, and non-linear dispersion effects would significantly change beam parameters. In contrast, photonic crystal fibres mainly guide the laser pulses in air, so that absorption and dispersive pulse broadening have essentially no effect. This article compares classical beam guidance with mirrors, lenses and prisms with photonic crystal fibres and describes the underlying concepts and the current state of technology. A classical mirror arm possesses more variable optical properties, while the HCF (Hollow-Core Photonic Crystal Fibre) must be matched in terms of the laser energy and the laser spectrum. In contrast, the HCF has more advantages in respect of handling, system integration and costs. For applications based on photodisruptive laser-tissue interaction, the relatively low damage threshold of photonic crystal fibres compared to classic beam guiding systems is unacceptable. If, however, pulsed laser radiation has a sufficiently low peak intensity, e.g. as used for plasma-induced ablation, photonic crystal fibres can definitely be considered as an alternative solution to classic beam guidance.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Refractometry / Ophthalmologic Surgical Procedures / Laser Therapy / Fiber Optic Technology / Lasers / Lenses Type of study: Guideline Language: De Journal: Klin Monbl Augenheilkd Year: 2017 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Refractometry / Ophthalmologic Surgical Procedures / Laser Therapy / Fiber Optic Technology / Lasers / Lenses Type of study: Guideline Language: De Journal: Klin Monbl Augenheilkd Year: 2017 Type: Article