Your browser doesn't support javascript.
loading
Radiolabeling of Preformed Niosomes with [99mTc]: In Vitro Stability, Biodistribution, and In Vivo Performance.
Almasi, Ameneh; Shahhosseini, Soraya; Haeri, Azadeh; Daha, Fariba Johari; Geramifar, Parham; Dadashzadeh, Simin.
Affiliation
  • Almasi A; Department of Pharmaceutics and Nanotechnology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Shahhosseini S; Department of Pharmaceutical Chemistry and Radiopharmacy, School of Pharmacy and Protein Technology Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran. s_shahoseini@sbmu.ac.ir.
  • Haeri A; Department of Pharmaceutics and Nanotechnology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Daha FJ; Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Geramifar P; Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  • Dadashzadeh S; Department of Pharmaceutics and Nanotechnology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran. sdadashzadeh@sbmu.ac.ir.
AAPS PharmSciTech ; 19(8): 3859-3870, 2018 Nov.
Article in En | MEDLINE | ID: mdl-30291544
ABSTRACT
Nanocarriers radiolabeled with [99mTc] can be used for diagnostic imaging and radionuclide therapy, as well as tracking their pharmacokinetic and biodistribution characteristics. Due to the advantages of niosomes as an ideal drug delivery system, in this study, the radiolabeling procedure of niosomes by [99mTc]-HMPAO complexes was investigated and optimized. Glutathione (GSH)-loaded niosomes were prepared using a thin-film hydration method. To label the niosomes with [99mTc], the preformed GSH-loaded niosomes were incubated with the [99mTc]-HMPAO complex and were characterized for particle size, size distribution, zeta potential, morphology, and radiolabeling efficiency (RE). The effects of GSH concentration, incubation time, incubation temperature, and niosomal composition on RE were investigated. The biodistribution profile and in vivo SPECT/CT imaging of the niosomes and free [99mTc]-HMPAO were also studied. Based on the results, all vesicles had nano-sized structure (160-235 nm) and negative surface charge. Among the different experimental conditions that were tested, including various incubation times, incubation temperatures, and GSH concentrations, the optimum condition that resulted in a RE of 92% was 200-mM GSH and 15-min incubation at 40°C. The in vitro release study in plasma showed that about 20% of radioactivity was released after 24 h, indicating an acceptable radiolabeling stability in plasma. The biodistribution of niosomes was clearly different from the free radiolabel. Niosomes carrying radionuclide were successfully used for tracking the in vivo disposition of these carriers and SPECT/CT imaging in rats. Furthermore, biodistribution studies in tumor-bearing mice revealed higher tumor accumulation of the niosomal formulation as compared with [99mTc]-HMPAO.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Technetium Tc 99m Exametazime / Liposomes Type of study: Prognostic_studies Limits: Animals / Female / Humans / Male Language: En Journal: AAPS PharmSciTech Journal subject: FARMACOLOGIA Year: 2018 Type: Article Affiliation country: Iran

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Technetium Tc 99m Exametazime / Liposomes Type of study: Prognostic_studies Limits: Animals / Female / Humans / Male Language: En Journal: AAPS PharmSciTech Journal subject: FARMACOLOGIA Year: 2018 Type: Article Affiliation country: Iran