A Wolter imager on the Z machine to diagnose warm x-ray sources.
Fein, J R; Ampleford, D J; Vogel, J K; Kozioziemski, B; Walton, C C; Wu, M; Ball, C R; Ames, A; Ayers, J; Bell, P; Bourdon, C J; Bradley, D; Bruni, R; Dunham, G S; Gard, P D; Johnson, D; Kilaru, K; Kirtley, C; Lake, P W; Maurer, A; Nielsen-Weber, L; Pickworth, L A; Pivovaroff, M J; Ramsey, B; Roberts, O J; Rochau, G A; Romaine, S; Sullivan, M.
Affiliation
  • Fein JR; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Ampleford DJ; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Vogel JK; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Kozioziemski B; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Walton CC; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Wu M; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Ball CR; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Ames A; Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, Massachusetts 02138, USA.
  • Ayers J; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Bell P; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Bourdon CJ; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Bradley D; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Bruni R; Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, Massachusetts 02138, USA.
  • Dunham GS; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Gard PD; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Johnson D; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Kilaru K; Universities Space Research Association, 320 Sparkman Drive, Huntsville, Alabama 35805, USA.
  • Kirtley C; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Lake PW; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Maurer A; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Nielsen-Weber L; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Pickworth LA; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Pivovaroff MJ; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Ramsey B; NASA-Marshall Spaceflight Center, Huntsville, Alabama 35811, USA.
  • Roberts OJ; Universities Space Research Association, 320 Sparkman Drive, Huntsville, Alabama 35805, USA.
  • Rochau GA; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
  • Romaine S; Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, Massachusetts 02138, USA.
  • Sullivan M; Sandia National Laboratories, 1515 Eubank Blvd SE, Albuquerque, New Mexico 87123, USA.
Rev Sci Instrum ; 89(10): 10G115, 2018 Oct.
Article in En | MEDLINE | ID: mdl-30399891
ABSTRACT
A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm3 field-of-view and measured 60-300-µm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. We provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.