Hard X-ray self-seeding commissioning at PAL-XFEL.
Min, Chang Ki; Nam, Inhyuk; Yang, Haeryong; Kim, Gyujin; Shim, Chi Hyun; Ko, Jun Ho; Cho, Myung Hoon; Heo, Hoon; Oh, Bonggi; Suh, Young Jin; Kim, Min Jae; Na, Donghyun; Kim, Changbum; Kim, Yongsam; Chun, Sae Hwan; Lee, Jae Hyuk; Kim, Jangwoo; Kim, Sunam; Eom, Intae; Kim, Seung Nam; Koo, Tae Yeong; Rah, Seungyu; Shvyd'ko, Yuri; Shu, Deming; Kim, Kwang Je; Terentyev, Sergey; Blank, Vladimir; Kang, Heung Sik.
Affiliation
  • Min CK; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Nam I; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Yang H; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim G; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Shim CH; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Ko JH; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Cho MH; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Heo H; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Oh B; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Suh YJ; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim MJ; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Na D; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim C; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim Y; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Chun SH; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Lee JH; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim J; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim S; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Eom I; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Kim SN; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Koo TY; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Rah S; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
  • Shvyd'ko Y; Argonne National Laboratory, Argonne, IL 60439-4815, USA.
  • Shu D; Argonne National Laboratory, Argonne, IL 60439-4815, USA.
  • Kim KJ; Argonne National Laboratory, Argonne, IL 60439-4815, USA.
  • Terentyev S; Technological Institute for Superhard and Novel Carbon Materials, Troitsk, Moscow 142190, Russian Federation.
  • Blank V; Technological Institute for Superhard and Novel Carbon Materials, Troitsk, Moscow 142190, Russian Federation.
  • Kang HS; Pohang Accelerator Laboratory, Pohang, Gyeongbuk 37673, Republic of Korea.
J Synchrotron Radiat ; 26(Pt 4): 1101-1109, 2019 Jul 01.
Article in En | MEDLINE | ID: mdl-31274433
ABSTRACT
A wake monochromator based on a large-area diamond single crystal for hard X-ray self-seeding has been successfully installed and commissioned in the hard X-ray free-electron laser (FEL) at the Pohang Accelerator Laboratory with international collaboration. For this commissioning, the self-seeding was demonstrated with a low bunch charge (40 pC) and the nominal bunch charge (180 pC) of self-amplified spontaneous emission (SASE) operation. The FEL pulse lengths were estimated as 7 fs and 29.5 fs, respectively. In both cases, the average spectral brightness increased by more than three times compared with the SASE mode. The self-seeding experiment was demonstrated for the first time using a crystal with a thickness of 30 µm, and a narrow bandwidth of 0.22 eV (full width at half-maximum) was obtained at 8.3 keV, which confirmed the functionality of a crystal with such a small thickness. In the nominal bunch-charge self-seeding experiment, the histogram of the intensity integrated over a 1 eV bandwidth showed a well defined Gaussian profile, which is evidence of the saturated FEL and a minimal electron-energy jitter (∼1.2 × 10-4) effect. The corresponding low photon-energy jitter (∼2.4 × 10-4) of the SASE FEL pulse, which is two times lower than the Pierce parameter, enabled the seeding power to be maximized by maintaining the spectral overlap between SASE FEL gain and the monochromator.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2019 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2019 Type: Article