Your browser doesn't support javascript.
loading
Methods for dynamic synchrotron X-ray respiratory imaging in live animals.
Morgan, Kaye Susannah; Parsons, David; Cmielewski, Patricia; McCarron, Alexandra; Gradl, Regine; Farrow, Nigel; Siu, Karen; Takeuchi, Akihisa; Suzuki, Yoshio; Uesugi, Kentaro; Uesugi, Masayuki; Yagi, Naoto; Hall, Chris; Klein, Mitzi; Maksimenko, Anton; Stevenson, Andrew; Hausermann, Daniel; Dierolf, Martin; Pfeiffer, Franz; Donnelley, Martin.
Affiliation
  • Morgan KS; School of Physics and Astronomy, Monash University, Wellington Road, Clayton, VIC 3800, Australia.
  • Parsons D; Robinson Research Institute, University of Adelaide, SA 5006, Australia.
  • Cmielewski P; Robinson Research Institute, University of Adelaide, SA 5006, Australia.
  • McCarron A; Robinson Research Institute, University of Adelaide, SA 5006, Australia.
  • Gradl R; Institute for Advanced Study, Technische Universität München, Garching Germany.
  • Farrow N; Robinson Research Institute, University of Adelaide, SA 5006, Australia.
  • Siu K; School of Physics and Astronomy, Monash University, Wellington Road, Clayton, VIC 3800, Australia.
  • Takeuchi A; SPring-8, Japan Synchrotron Radiation Institute, Kouto, Hyogo, Japan.
  • Suzuki Y; SPring-8, Japan Synchrotron Radiation Institute, Kouto, Hyogo, Japan.
  • Uesugi K; SPring-8, Japan Synchrotron Radiation Institute, Kouto, Hyogo, Japan.
  • Uesugi M; SPring-8, Japan Synchrotron Radiation Institute, Kouto, Hyogo, Japan.
  • Yagi N; SPring-8, Japan Synchrotron Radiation Institute, Kouto, Hyogo, Japan.
  • Hall C; Imaging and Medical Beamline, The Australian Synchrotron - ANSTO, 800 Blackburn Road, Clayton, VIC 3168, Australia.
  • Klein M; Imaging and Medical Beamline, The Australian Synchrotron - ANSTO, 800 Blackburn Road, Clayton, VIC 3168, Australia.
  • Maksimenko A; Imaging and Medical Beamline, The Australian Synchrotron - ANSTO, 800 Blackburn Road, Clayton, VIC 3168, Australia.
  • Stevenson A; Imaging and Medical Beamline, The Australian Synchrotron - ANSTO, 800 Blackburn Road, Clayton, VIC 3168, Australia.
  • Hausermann D; Imaging and Medical Beamline, The Australian Synchrotron - ANSTO, 800 Blackburn Road, Clayton, VIC 3168, Australia.
  • Dierolf M; Chair of Biomedical Physics and Munich School of BioEngineering, Technische Universität München, 85748 Garching, Germany.
  • Pfeiffer F; Institute for Advanced Study, Technische Universität München, Garching Germany.
  • Donnelley M; Robinson Research Institute, University of Adelaide, SA 5006, Australia.
J Synchrotron Radiat ; 27(Pt 1): 164-175, 2020 Jan 01.
Article in En | MEDLINE | ID: mdl-31868749
ABSTRACT
Small-animal physiology studies are typically complicated, but the level of complexity is greatly increased when performing live-animal X-ray imaging studies at synchrotron and compact light sources. This group has extensive experience in these types of studies at the SPring-8 and Australian synchrotrons, as well as the Munich Compact Light Source. These experimental settings produce unique challenges. Experiments are always performed in an isolated radiation enclosure not specifically designed for live-animal imaging. This requires equipment adapted to physiological monitoring and test-substance delivery, as well as shuttering to reduce the radiation dose. Experiment designs must also take into account the fixed location, size and orientation of the X-ray beam. This article describes the techniques developed to overcome the challenges involved in respiratory X-ray imaging of live animals at synchrotrons, now enabling increasingly sophisticated imaging protocols.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Respiratory System / Radiography / Respiratory Mechanics / Synchrotrons Type of study: Diagnostic_studies Limits: Animals Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2020 Type: Article Affiliation country: Australia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Respiratory System / Radiography / Respiratory Mechanics / Synchrotrons Type of study: Diagnostic_studies Limits: Animals Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2020 Type: Article Affiliation country: Australia