Your browser doesn't support javascript.
loading
Flattening filter for Gaussian-shaped monochromatic X-ray beams: an application to breast computed tomography.
Donato, Sandro; Arfelli, Fulvia; Brombal, Luca; Longo, Renata; Pinto, Andrea; Rigon, Luigi; Dreossi, Diego.
Affiliation
  • Donato S; Department of Physics, University of Trieste, 34127 Trieste, Italy.
  • Arfelli F; Department of Physics, University of Trieste, 34127 Trieste, Italy.
  • Brombal L; Department of Physics, University of Trieste, 34127 Trieste, Italy.
  • Longo R; Department of Physics, University of Trieste, 34127 Trieste, Italy.
  • Pinto A; Department of Medicine, Surgery and Health Sciences, University of Trieste, 34127 Trieste, Italy.
  • Rigon L; Department of Physics, University of Trieste, 34127 Trieste, Italy.
  • Dreossi D; Elettra-Sincrotrone Trieste SCpA, 34149 Trieste, Italy.
J Synchrotron Radiat ; 27(Pt 2): 503-506, 2020 Mar 01.
Article in En | MEDLINE | ID: mdl-32153291
The vertical intensity distribution of synchrotron-based X-ray beams usually has a Gaussian profile encompassing large intensity variations. For biomedical imaging applications this may entail sub-optimal dose distributions and large fluctuations in terms of image noise. Commonly, planar metallic filters coupled with absorbing slits systems are applied to adjust the delivered flux and to limit intensity variations, respectively. The latter results in a reduction of the effective beam size. A flattening filter that counterbalances the transverse inhomogeneity, while retaining a sufficient flux, has been developed in the context of a monochromatic phase-contrast breast computed tomography application, ongoing at the Elettra synchrotron facility. The implementation of the new filtration system results in homogeneous intensity (hence dose) distribution and signal-to-noise ratio across the imaged volume. Finally, and most importantly, it allows a wider portion of the beam to be used, directly translating into a major (∼40%) reduction of the overall scan time for samples requiring a field of view larger than the beam size (i.e. multiple translation steps).
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Breast Neoplasms / Tomography, X-Ray Computed Limits: Female / Humans Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2020 Type: Article Affiliation country: Italy

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Breast Neoplasms / Tomography, X-Ray Computed Limits: Female / Humans Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2020 Type: Article Affiliation country: Italy