On the Reliability of Suction Measurements for Skin Characterization.
Mueller, Bettina; Elrod, Julia; Distler, Oliver; Schiestl, Clemens; Mazza, Edoardo.
Affiliation
  • Mueller B; Institute for Mechanical Systems, ETH Zurich, Leonhardstrasse 21, Zürich 8092, Switzerland.
  • Elrod J; Department of Surgery, University Children's Hospital Zurich, Steinwiesstrasse 75, Zürich 8032, Switzerland; Children's Research Center (CRC), University Children's Hospital Zurich, Steinwiesstrasse 75, Zürich 8032, Switzerland.
  • Distler O; Department of Rheumatology, University Hospital Zurich, Gloriastrasse 25, Zurich 8091, Switzerland.
  • Schiestl C; Department of Surgery, University Children's Hospital Zurich, Steinwiesstrasse 75, Zürich 8032, Switzerland; Children's Research Center (CRC), University Children's Hospital Zurich, Steinwiesstrasse 75, Zürich 8032, Switzerland.
  • Mazza E; Institute for Mechanical Systems, ETH Zurich, Leonhardstrasse 21, Zürich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland.
J Biomech Eng ; 143(2)2021 02 01.
Article in En | MEDLINE | ID: mdl-32601661
ABSTRACT
in vivo skin characterization methods were shown to be useful in the detection of microstructural alterations of the dermis due to skin diseases. Specifically, the diagnostic potential of skin suction has been widely explored, yet measurement uncertainties prevented so far its application in clinical assessment. In this work, we analyze specific factors influencing the reliability of suction measurements. We recently proposed a novel suction device, called Nimble, addressing the limitations of existing instruments, and applied it in clinical trials quantifying mechanical differences between healthy skin and scars. Measurements were performed with the commercial device Cutometer and with the new device. A set of new suction measurements was carried out on scar tissue and healthy skin, and FE-based inverse analysis was applied to determine corresponding parameters of a hyperelastic-viscoelastic material model. FE simulations were used to rationalize differences between suction protocols and to analyze specific factors influencing the measurement procedure. Tissue stiffness obtained from Cutometer measurements was significantly higher compared to the one from Nimble measurements, which was shown to be associated with the higher deformation levels in the Cutometer and the nonlinear mechanical response of skin. The effect of the contact force exerted on skin during suction measurements was quantified, along with an analysis of the effectiveness of a corresponding correction procedure. Parametric studies demonstrated the inherently higher sensitivity of displacement- over load-controlled suction measurements, thus rationalizing the superior ability of the Nimble to distinguish between tissues.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Skin Type of study: Guideline / Prognostic_studies Limits: Adult / Humans Language: En Journal: J Biomech Eng Year: 2021 Type: Article Affiliation country: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Skin Type of study: Guideline / Prognostic_studies Limits: Adult / Humans Language: En Journal: J Biomech Eng Year: 2021 Type: Article Affiliation country: Switzerland