Your browser doesn't support javascript.
loading
Cucurbituril and zwitterionic surfactant-based matrix solid-phase dispersion microextraction to simultaneously determine terpenoids from Radix Curcumae.
Chen, Yan; Zhen, Xiao-Ting; Yu, Ya-Ling; Shi, Min-Zhen; Cao, Jun; Zheng, Hui; Ye, Li-Hong.
Affiliation
  • Chen Y; College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, P. R. China.
  • Zhen XT; College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, P. R. China.
  • Yu YL; College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, P. R. China.
  • Shi MZ; College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, P. R. China.
  • Cao J; College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, P. R. China.
  • Zheng H; College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, P. R. China.
  • Ye LH; Department of Traditional Chinese Medicine, Hangzhou Red Cross Hospital, Hangzhou, P. R. China.
J Sep Sci ; 44(7): 1361-1370, 2021 Apr.
Article in En | MEDLINE | ID: mdl-33432733
ABSTRACT
A rapid, efficient, and environmentally friendly matrix solid-phase dispersion microextraction was established to determine and quantify terpenoids in Radix Curcumae using ultra-high-performance liquid chromatography with a diode array detector. Various parameters affecting the extraction were investigated in detail, such as the grinding time, amount of adsorbent, type and concentration of elution solvent, and pH. The optimization of single-factor and response surface methodology was performed to confirm the best conditions in this procedure. The final optimized conditions were obtained by applying 70 mg of cucurbituril as adsorbent, 149 s as the optimum grinding time, and 228 mM of 3-(N,N-dimethylpalmitylammonio)propanesulfonate aqueous solution (pH 6.5) as the optimal elution solvent. The validated method showed a satisfactory linear range of 0.10-10 µg/mL for curdione and furanodiene, 0.01-10 µg/mL for isocurcumenol and germacrone, and 0.05-10 µg/mL for furanodienone, while the correlation coefficients ranged from 0.9945 to 0.9970. The recoveries of the investigated analytes at two spiked concentration levels (0.1 and 1.0 µg/mL) ranged from 96.53 to 104.60%. In addition, this method displayed acceptable reproducibility (relative standard deviation ≤ 3.66%). The results showed that the newly proposed matrix solid-phase dispersion microextraction method was successfully applied to analyze curdione, isocurcumenol, furanodienone, germacrone and furanodiene in Radix Curcumae samples.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Surface-Active Agents / Terpenes / Curcuma / Macrocyclic Compounds / Solid Phase Microextraction Language: En Journal: J Sep Sci Year: 2021 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Surface-Active Agents / Terpenes / Curcuma / Macrocyclic Compounds / Solid Phase Microextraction Language: En Journal: J Sep Sci Year: 2021 Type: Article