Your browser doesn't support javascript.
loading
Comparative evaluation of 19 reverse transcription loop-mediated isothermal amplification assays for detection of SARS-CoV-2.
Dong, Yajuan; Wu, Xiuming; Li, Shenwei; Lu, Renfei; Li, Yingxue; Wan, Zhenzhou; Qin, Jianru; Yu, Guoying; Jin, Xia; Zhang, Chiyu.
Affiliation
  • Dong Y; Shanghai Public Health Clinical Center, Fudan University, Shanghai, 201508, China.
  • Wu X; College of Life Sciences, Henan Normal University, Xinxiang, 453007, China.
  • Li S; Pathogen Discovery and Evolution Unit, Institut Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai, China.
  • Lu R; Tobacco Research Institute, Chinese Academy of Agricultural Sciences, Qingdao, Shandong, 266101, China.
  • Li Y; Shanghai International Travel Healthcare Center, Shanghai, 200335, China.
  • Wan Z; Clinical Laboratory, Nantong Third Hospital Affiliated To Nantong University, Nantong, 226006, China.
  • Qin J; Shanghai Public Health Clinical Center, Fudan University, Shanghai, 201508, China.
  • Yu G; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China.
  • Jin X; Medical Laboratory of Taizhou Fourth People's Hospital, Taizhou, 225300, China.
  • Zhang C; College of Life Sciences, Henan Normal University, Xinxiang, 453007, China.
Sci Rep ; 11(1): 2936, 2021 02 03.
Article in En | MEDLINE | ID: mdl-33536475
ABSTRACT
Coronavirus disease 2019 (COVID-19) caused by SARS-CoV-2 has caused a global pandemics. To facilitate the detection of SARS-CoV-2 infection, various RT-LAMP assays using 19 sets of primers had been developed, but never been compared. We performed comparative evaluation of the 19 sets of primers using 4 RNA standards and 29 clinical samples from COVID-19 patients. Six of 15 sets of primers were firstly identified to have faster amplification when tested with four RNA standards, and were further subjected to parallel comparison with the remaining four primer sets using 29 clinical samples. Among these 10 primer sets, Set-4 had the highest positive detection rate of SARS-CoV-2 (82.8%), followed by Set-10, Set-11, and Set-13 and Set-17 (75.9%). Set-14 showed the fastest amplification speed (Tt value < 8.5 min), followed by Set-17 (Tt value < 12.5 min). Based on the overall detection performance, Set-4, Set-10, Set-11, Set-13, Set-14 and Set-17 that target Nsp3, S, S, E, N and N gene regions of SARS-CoV-2, respectively, were determined to be better than the other primer sets. Two RT-LAMP assays with the Set-4 primers in combination with any one of four other primer sets (Set-14, Set-10, Set-11, and Set-13) were recommended to be used in the COVID-19 surveillance.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: RNA, Viral / Nucleic Acid Amplification Techniques / SARS-CoV-2 / COVID-19 Type of study: Diagnostic_studies / Guideline / Prognostic_studies Limits: Humans Language: En Journal: Sci Rep Year: 2021 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: RNA, Viral / Nucleic Acid Amplification Techniques / SARS-CoV-2 / COVID-19 Type of study: Diagnostic_studies / Guideline / Prognostic_studies Limits: Humans Language: En Journal: Sci Rep Year: 2021 Type: Article Affiliation country: China