Your browser doesn't support javascript.
loading
Deep-learning-based image reconstruction in dynamic contrast-enhanced abdominal CT: image quality and lesion detection among reconstruction strength levels.
Kaga, T; Noda, Y; Fujimoto, K; Suto, T; Kawai, N; Miyoshi, T; Hyodo, F; Matsuo, M.
Affiliation
  • Kaga T; Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan.
  • Noda Y; Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan. Electronic address: noda1031@gifu-u.ac.jp.
  • Fujimoto K; Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan.
  • Suto T; Department of Radiology, Gifu Municipal Hospital, Gifu, Japan.
  • Kawai N; Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan.
  • Miyoshi T; Department of Radiology Services, Gifu University Hospital, Gifu, Japan.
  • Hyodo F; Department of Radiology, Frontier Science for Imaging, Gifu University, Gifu, Japan.
  • Matsuo M; Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan.
Clin Radiol ; 76(9): 710.e15-710.e24, 2021 Sep.
Article in En | MEDLINE | ID: mdl-33879322
ABSTRACT

AIM:

To evaluate the use of deep-learning-based image reconstruction (DLIR) algorithms in dynamic contrast-enhanced computed tomography (CT) of the abdomen, and to compare the image quality and lesion conspicuity among the reconstruction strength levels. MATERIALS AND

METHODS:

This prospective study included 59 patients with 373 hepatic lesions who underwent dynamic contrast-enhanced CT of the abdomen. All images were reconstructed using four reconstruction algorithms, including 40% adaptive statistical iterative reconstruction-Veo (ASiR-V) and DLIR at low, medium, and high-strength levels (DLIR-L, DLIR-M, and DLIR-H, respectively). The signal-to-noise ratio (SNR) of the abdominal aorta, portal vein, liver, pancreas, and spleen and the lesion-to-liver contrast-to-noise ratio (CNR) were calculated and compared among the four reconstruction algorithms. The diagnostic acceptability was qualitatively assessed and compared among the four reconstruction algorithms and the conspicuity of hepatic lesions was compared between <5 and ≥5 mm lesions.

RESULTS:

The SNR of each anatomical structure (p<0.0001) and CNR (p<0.0001) were significantly higher in DLIR-H than the other reconstruction algorithms. Diagnostic acceptability was significantly better in DLIR-M than the other reconstruction algorithms (p<0.0001). The conspicuity of hepatic lesions was highest when using 40% ASiR-V and tended to lessen as the reconstruction strength level was getting higher in DLIR, especially in <5 mm lesions; however, all hepatic lesions could be detected.

CONCLUSIONS:

DLIR improved the SNR, CNR, and image quality compared with 40% ASiR-V, while making it possible to decrease lesion conspicuity using higher reconstruction strength.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiographic Image Interpretation, Computer-Assisted / Radiographic Image Enhancement / Tomography, X-Ray Computed / Contrast Media / Deep Learning / Abdominal Neoplasms Type of study: Diagnostic_studies / Observational_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Clin Radiol Year: 2021 Type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiographic Image Interpretation, Computer-Assisted / Radiographic Image Enhancement / Tomography, X-Ray Computed / Contrast Media / Deep Learning / Abdominal Neoplasms Type of study: Diagnostic_studies / Observational_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Clin Radiol Year: 2021 Type: Article Affiliation country: Japan