Your browser doesn't support javascript.
loading
The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine.
Purgat, Krystian; Koska, Izabella; Kubalczyk, Pawel.
Affiliation
  • Purgat K; Department of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163 Pomorska Str., 90-236 Lodz, Poland.
  • Koska I; Department of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163 Pomorska Str., 90-236 Lodz, Poland.
  • Kubalczyk P; Doctoral School of Exact and Natural Sciences, University of Lodz, 12/16 Banacha Str., 90-237 Lodz, Poland.
Molecules ; 26(18)2021 Sep 20.
Article in En | MEDLINE | ID: mdl-34577158
ABSTRACT
Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with field amplified sample injection (FASI). The off-line SDME protocol consists of the following

steps:

urine dilution with 0.2 mol/L, pH 8.2 phosphate buffer (12, v/v), chloroform addition, drop formation and extraction of HTL. The pre-concentration of HTL inside a separation capillary was performed by FASI. For sample separation, the 0.1 mol/L pH 4.75 phosphate buffer served as the background electrolyte, and HTL was detected at 240 nm. A standard fused-silica capillary (effective length 55.5 cm, 75 µm id) and a separation voltage of 21 kV (~99 µA) were used. Electrophoretic separation was completed within 7 min, whereas the LOD and LOQ for HTL were 0.04 and 0.1 µmol/L urine, respectively. The calibration curve in urine was linear in the range of 0.1-0.5 µmol/L, with R2 = 0.9991. The relative standard deviation of the points of the calibration curve varied from 2.4% to 14.9%. The intra- and inter-day precision and recovery were 6.4-10.2% (average 6.0% and 6.7%) and 94.9-102.7% (average 99.7% and 99.5%), respectively. The analytical procedure was successfully applied to the analysis of spiked urine samples obtained from apparently healthy volunteers.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electrophoresis, Capillary / Liquid Phase Microextraction / Homocysteine Limits: Female / Humans / Male Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2021 Type: Article Affiliation country: Poland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electrophoresis, Capillary / Liquid Phase Microextraction / Homocysteine Limits: Female / Humans / Male Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2021 Type: Article Affiliation country: Poland