Your browser doesn't support javascript.
loading
Fluorescent polydopamine based molecularly imprinted sensor for ultrafast and selective detection of p-nitrophenol in drinking water.
Xu, Yeqing; Huang, Ting; Meng, Minjia; Yan, Yongsheng.
Affiliation
  • Xu Y; Institute of Green Chemistry and Chemical Technology, Advanced Chemical Engineering Laboratory of Green Materials and Energy of Jiangsu Province, School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China.
  • Huang T; Institute of Green Chemistry and Chemical Technology, Advanced Chemical Engineering Laboratory of Green Materials and Energy of Jiangsu Province, School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China.
  • Meng M; Institute of Green Chemistry and Chemical Technology, Advanced Chemical Engineering Laboratory of Green Materials and Energy of Jiangsu Province, School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China. mmj@ujs.edu.cn.
  • Yan Y; Institute of Green Chemistry and Chemical Technology, Advanced Chemical Engineering Laboratory of Green Materials and Energy of Jiangsu Province, School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China. yys@ujs.edu.cn.
Mikrochim Acta ; 189(1): 25, 2021 12 11.
Article in En | MEDLINE | ID: mdl-34897555
ABSTRACT
A highly effective fluorescent molecularly imprinted sensor (F-PDA-MIS) based on fluorescent polydopamine (F-PDA) was successfully synthesized for selective and ultrafast detection of p-nitrophenol (P-NP) in drinking water. F-PDA with abundant surface functional groups has been artfully modified to firstly serve as both fluorescent monomer and functional monomer in the synthesis of a uniform luminous F-PDA-MIS, which can greatly improve the detection efficiency. As expected, F-PDA-MIS had an obvious emission wavelength of 535 nm with the optimal excitation wavelength at 400 nm. Specially, F-PDA-MIS could detect P-NP in the range 100 to 1100 nM with much lower detection limit of 24.2 nM within 120 s compared with other conventional imprinted fluorescent sensors based on pure quantum dots (QDs) or dyes. This excellent test phenomenon is mainly ascribed to the rapid electron transfer between F-PDA and P-NP. Satisfactory recovery of 98.0-104% for mineral water and 98.6-106% for boiling water were obtained with relative standard deviations (RSDs) of 2.7-3.4% and 2.6-3.5% respectively. The detection reliability of F-PDA-MIS was verified by the comparison with high-performance liquid chromatography (HPLC-UV). Consequently, F-PDA as a fluorescence functional monomer has been shown to be a possible strategy to effectively improve the detection limit and shorten response time of the target determination in water..
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Water Pollutants, Chemical / Drinking Water / Fluorescent Dyes / Molecularly Imprinted Polymers / Indoles / Nitrophenols Type of study: Diagnostic_studies Language: En Journal: Mikrochim Acta Year: 2021 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Water Pollutants, Chemical / Drinking Water / Fluorescent Dyes / Molecularly Imprinted Polymers / Indoles / Nitrophenols Type of study: Diagnostic_studies Language: En Journal: Mikrochim Acta Year: 2021 Type: Article Affiliation country: China