Your browser doesn't support javascript.
loading
An In Vivo Comparison: Novel Mesh Suture Versus Traditional Suture-Based Repair in a Rabbit Tendon Model.
Janes, Lindsay E; Mioton, Lauren M; Fracol, Megan E; Ko, Jason H.
Affiliation
  • Janes LE; Division of Plastic and Reconstructive Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL.
  • Mioton LM; Division of Plastic and Reconstructive Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL.
  • Fracol ME; Division of Plastic and Reconstructive Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL.
  • Ko JH; Division of Plastic and Reconstructive Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL.
J Hand Surg Glob Online ; 4(1): 32-39, 2022 Jan.
Article in En | MEDLINE | ID: mdl-35415598
Purpose: Despite advancements in surgical techniques, suture pull-though and rupture continue to limit the early range of motion and functional rehabilitation after flexor tendon repairs. The aim of this study was to evaluate a suturable mesh compared with a commonly used braided suture in an in vivo rabbit intrasynovial tendon model. Methods: Twenty-four New Zealand female rabbits (3-4 kg) were injected with 2 units/kg botulinum toxin evenly distributed into 4 sites in the left calf. After 1 week, the animals underwent surgical tenotomy of the flexor digitorum tendon and were randomized to repair with either 2-0 Duramesh suturable mesh or to 2-0 Fiberwire using a 2-strand modified Kessler and 6-0 polypropylene running epitendinous suture. Rabbits were killed at 2, 4, and 9 weeks after surgery. Results: Grouping across time points, 58.3% (7 of 12) of Duramesh repairs were found to be intact for the explant compared with 16.7% (2 of 12) of Fiberwire repairs (P = .09). At 2 weeks, the mean Duramesh repairs were significantly stronger than the Fiberwire repairs with a mean failure load of 50.7 ± 12.7 N compared to 14.8 ± 18.3 N (P = .02). The load supported by the Duramesh repairs at 2 weeks (mean 50.7 ± 12.7 N) was similar to the load supported by both Fiberwire (52.2 ± 13.6 N) and Duramesh (57.6 ± 22.3 N) at 4 weeks. The strength of repair between Fiberwire and Duramesh at 4 weeks and 9 weeks was not significantly different. Conclusions: The 2-strand tendon repair with suturable mesh achieved significantly greater strength at 2 weeks than the conventional suture material. Future studies should evaluate the strength of repair prior to 2 weeks to determine the strength curve for this novel suture material. Clinical Relevance: This study evaluates the utility of a novel suturable mesh for flexor tendon repair in an in vivo rabbit model compared with conventional suture material.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Clinical_trials Language: En Journal: J Hand Surg Glob Online Year: 2022 Type: Article