Your browser doesn't support javascript.
loading
Modification of a polyethersulfone membrane with a block copolymer brush of poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) and a branched polypeptide chain of Arg-Glu-Asp-Val.
Niu, Xiaoqin; Li, Dan; Chen, Yuhong; Ran, Fen.
Affiliation
  • Niu X; College of Petrochemical Technology, Lanzhou University of Technology Lanzhou 730050 P. R. China chenyh@lut.cn.
  • Li D; School of Material Science and Engineering, Lanzhou University of Technology Lanzhou 730050 Gansu P. R. China.
  • Chen Y; College of Petrochemical Technology, Lanzhou University of Technology Lanzhou 730050 P. R. China chenyh@lut.cn.
  • Ran F; State Key Laboratory of Advanced Processing and Recycling of Non-ferrous Metals, Lanzhou University of Technology Lanzhou 730050 P. R. China ranfen@163.com ranfen@lut.cn.
RSC Adv ; 9(44): 25274-25284, 2019 Aug 13.
Article in En | MEDLINE | ID: mdl-35530106
ABSTRACT
Polyethersulfone (PES) has good thermal stability, superior pH, chlorine tolerance, and excellent chemical resistance; however, the hydrophilicity and biocompatibility of PES need to be improved for its real applications. In this study, we report a surface modification method for the preparation of a functional PES membrane with hydrophilic polymer chains (MPC and GMA) via surface-initiated electrochemically-mediated atom-transfer radical polymerization (SI-eATRP) technology, and the Arg-Glu-Asp-Val polypeptide groups (REDV) were immobilized onto the modified membrane by a ring-opening reaction. XPS and SEM were used to analyze the chemical composition and morphology of the modified membrane surfaces, confirming that the hydrophilic polymer chains MPC and GMA and the polypeptide group REDV were successfully grafted onto the PES membrane surface. The static water contact angle decreased from 89° to 50-65°, and the hydrophilic property of the modified membrane was enhanced. The water flux increased from 4.29 L m-2 h-1 for the pristine PES membrane to 25 L m-2 h-1 for the modified membrane with PGMA chains grafted on it and REDV functional groups immobilized on it; note that the antifouling tests showed that all the modified membranes had the higher flux recovery ratio values (FRR) of above 80% than the pristine PES membrane (about 60%), and the APTT for the modified membrane increased from 46 s to 93 s, indicating that these modified membranes could be applied in the separation and blood purification fields.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2019 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2019 Type: Article