Your browser doesn't support javascript.
loading
Feasibility, Safety, and Short-Term Outcomes of Transcatheter Patent Ductus Arteriosus Closure in Premature Infants on High-Frequency Jet Ventilation.
Shibbani, Kamel; Mohammad Nijres, Bassel; McLennan, Daniel; Bischoff, Adrianne Rahde; Giesinger, Regan; McNamara, Patrick J; Klein, Jonathan; Windsor, Jimmy; Aldoss, Osamah.
Affiliation
  • Shibbani K; Division of Pediatric Cardiology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • Mohammad Nijres B; Division of Pediatric Cardiology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • McLennan D; Division of Pediatric Cardiology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • Bischoff AR; Division of Neonatology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • Giesinger R; Division of Neonatology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • McNamara PJ; Division of Pediatric Cardiology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • Klein J; Division of Neonatology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • Windsor J; Division of Neonatology Stead Family Children's Hospital University of Iowa Iowa City IA.
  • Aldoss O; Division of Pediatric Anesthesia University of Iowa Carver College of Medicine Iowa City IA.
J Am Heart Assoc ; 11(10): e025343, 2022 05 17.
Article in En | MEDLINE | ID: mdl-35574958
Background Prolonged exposure to a hemodynamically significant patent ductus arteriosus (PDA) is associated with major morbidity, particularly in infants born at <27 weeks' gestation. High-frequency jet ventilation (HFJV) is a standard of care at our center. There are no data about transcatheter PDA closure while on HFJV. The aim of this study was to assess the feasibility, safety, and outcomes of HFJV during transcatheter PDA closure. Methods and Results This is a retrospective cohort study of premature infants undergoing transcatheter device closure on HFJV. The primary outcome was successful device placement. Secondary outcomes included procedure time, fluoroscopy time and dose, time off unit, device complications, need for escalation in respiratory support, and 7-day survival. Subgroup comparative evaluation of patients managed with HFJV versus a small cohort of patients managed with conventional mechanical ventilation was performed. Thirty-eight patients were included in the study. Median age and median weight at PDA device closure for the HFJV cohort were 32 days (interquartile range, 25.25-42.0 days) and 1115 g (interquartile range, 885-1310 g), respectively. There was successful device placement in 100% of patients. There were no device complications noted. The time off unit and the procedure time were not significantly different between the HFJV group and the conventional ventilation group. Infants managed by HFJV had shorter median fluoroscopy times (4.5 versus 6.1 minutes; P<0.05) and no increased risk of adverse respiratory outcomes. Conclusions Transcatheter PDA closure in premature infants on HFJV is a safe and effective approach that does not compromise device placement success rate and does not lead to secondary complications.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: High-Frequency Jet Ventilation / Ductus Arteriosus, Patent Type of study: Observational_studies / Risk_factors_studies Limits: Humans / Infant / Newborn Language: En Journal: J Am Heart Assoc Year: 2022 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: High-Frequency Jet Ventilation / Ductus Arteriosus, Patent Type of study: Observational_studies / Risk_factors_studies Limits: Humans / Infant / Newborn Language: En Journal: J Am Heart Assoc Year: 2022 Type: Article