Your browser doesn't support javascript.
loading
Automation of intracoronary continuous thermodilution for absolute coronary flow and microvascular resistance measurements.
Candreva, Alessandro; Gallinoro, Emanuele; Fernandez Peregrina, Estefania; Sonck, Jeroen; Keulards, Danielle C J; Van't Veer, Marcel; Mizukami, Takuya; Pijls, Nico H J; Collet, Carlos; De Bruyne, Bernard.
Affiliation
  • Candreva A; Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
  • Gallinoro E; Department of Cardiology, Zurich University Hospital, Zurich, Switzerland.
  • Fernandez Peregrina E; Department of Mechanical and Aerospace Engineering, PoliToBIO Med Lab, Politecnico di Torino, Turin, Italy.
  • Sonck J; Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
  • Keulards DCJ; Department of Translational Medical Sciences, University of Campania 'Luigi Vanvitelli', Naples, Italy.
  • Van't Veer M; Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
  • Mizukami T; Department of Interventional Cardiology, Hospital de la Santa Creu I Sant Pau, Barcelona, Spain.
  • Pijls NHJ; Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
  • Collet C; Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands.
  • De Bruyne B; Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Catheter Cardiovasc Interv ; 100(2): 199-206, 2022 08.
Article in En | MEDLINE | ID: mdl-35723684
AIM: Microvascular resistance reserve (MRR) as derived from continuous intracoronary thermodilution specifically quantifies microvasculature function. As originally described, the technique necessitates reinstrumentation of the artery and manual reprogramming of the infusion pump when performing resting and hyperemic measurements. To simplify and to render this procedure operator-independent, we developed a fully automated method. The aim of the present study is to validate the automated procedure against the originally described one. METHODS AND RESULTS: For the automated procedure, an infusion pump was preprogrammed to allow paired resting-hyperemic thermodilution assessment without interruption. To validate the accuracy of this new approach, 20 automated measurements were compared to those obtained in the same vessels with conventional paired resting-hyperemic thermodilution measurements (i.e., with a sensor pullback at each infusion rate and manual reprogramming of the infusion pump).  A close correlation between the conventional and the automated measuring technique was found for resting flow (Qrest : r = 0.89, mean bias = 2.52; SD = 15.47), hyperemic flow (Qhyper : r = 0.88, mean bias = -2.65; SD = 27.96), resting microvascular resistance (Rµ-rest : r = 0.90, mean bias = 52.14; SD = 228.29), hyperemic microvascular resistance Rµ-hyper : r = 0.92, mean bias = 12.95; SD = 57.80), and MRR (MRR: r = 0.89, mean bias = 0.04, SD = 0.59).  Procedural time was significantly shorter with the automated method (5'25″ ± 1'23″ vs. 4'36″ ± 0'33″, p = 0.013). CONCLUSION: Continuous intracoronary thermodilution-derived measurements of absolute flow, absolute resistance, and MRR can be fully automated. This further shortens and simplifies the procedure when performing paired resting-hyperemic measurements.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Thermodilution / Hyperemia Limits: Humans Language: En Journal: Catheter Cardiovasc Interv Journal subject: CARDIOLOGIA Year: 2022 Type: Article Affiliation country: Belgium

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Thermodilution / Hyperemia Limits: Humans Language: En Journal: Catheter Cardiovasc Interv Journal subject: CARDIOLOGIA Year: 2022 Type: Article Affiliation country: Belgium