Your browser doesn't support javascript.
loading
Biopsy channel of the endoscope as a potential source of infectious droplets during GI endoscopy.
Coughlan, Mark F; Sawhney, Mandeep S; Pleskow, Douglas K; Khan, Umar; Silva-Santisteban, Andy; Ahmed, Awais; Zhang, Xuejun; Glyavina, Maria; Chen, Liming; Upputuri, Paul K; Zakharov, Yuri N; Zhang, Lei; Qiu, Le; Perelman, Lev T.
Affiliation
  • Coughlan MF; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Sawhney MS; Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Pleskow DK; Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Khan U; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Silva-Santisteban A; Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Ahmed A; Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Zhang X; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Glyavina M; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Chen L; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Upputuri PK; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Zakharov YN; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Zhang L; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Qiu L; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Perelman LT; Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA; Biological and Biomedical Sciences Program, Harvard University, Boston, Massachusetts, USA.
Gastrointest Endosc ; 96(5): 764-770, 2022 11.
Article in En | MEDLINE | ID: mdl-35724696
BACKGROUND AND AIMS: During endoscopy, droplets with the potential to transmit infectious diseases are known to emanate from a patient's mouth and anus, but they may also be expelled from the biopsy channel of the endoscope. The main goal of our study was to quantify droplets emerging from the biopsy channel during clinical endoscopy. METHODS: A novel light-scattering device was used to measure droplets emanating from the biopsy channel. An endoscopy model was created, and in vitro measurements were carried out during air insufflation, air and water suctioning, and the performance of biopsy sampling. Similar measurements were then made on patients undergoing endoscopy, with all measurements taking place over 2 days to minimize variation. RESULTS: During in vitro testing, no droplets were observed at the biopsy channel during air insufflation or air and water suctioning. In 3 of 5 cases, droplets were observed during biopsy sampling, mostly when the forceps were being removed from the endoscope. In the 22 patients undergoing routine endoscopy, no droplets were observed during air insufflation and water suctioning. Droplets were detected in 1 of 11 patients during air suctioning. In 9 of 18 patients undergoing biopsy sampling and 5 of 6 patients undergoing snare polypectomies, droplets were observed at the biopsy channel, mostly when instruments were being removed from the endoscope. CONCLUSIONS: We found that the biopsy channel may be a source of infectious droplets, especially during the removal of instruments from the biopsy channel. When compared with droplets reported from the mouth and anus, these droplets were larger in size and therefore potentially more infectious.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Communicable Diseases / Endoscopes Limits: Humans Language: En Journal: Gastrointest Endosc Year: 2022 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Communicable Diseases / Endoscopes Limits: Humans Language: En Journal: Gastrointest Endosc Year: 2022 Type: Article Affiliation country: United States