Your browser doesn't support javascript.
loading
Assessing the Impact of Punch Geometries on Tablet Capping Using a Newly Proposed Capping Index.
Patel, Vivek D; Patel, Devang B; Sturgis, John C; Queensen, Kevin; Sedlock, Robert; Haware, Rahul V.
Affiliation
  • Patel VD; Natoli Scientific, A Division of Natoli Engineering Company, Inc., 100 Emlen Way, Suite # 104-108, Telford, PA-18969, USA.
  • Patel DB; Natoli Scientific, A Division of Natoli Engineering Company, Inc., 100 Emlen Way, Suite # 104-108, Telford, PA-18969, USA.
  • Sturgis JC; Natoli Scientific, A Division of Natoli Engineering Company, Inc., 100 Emlen Way, Suite # 104-108, Telford, PA-18969, USA.
  • Queensen K; Natoli Engineering Company, Inc., Saint Charles, MO, 63304, USA.
  • Sedlock R; Natoli Scientific, A Division of Natoli Engineering Company, Inc., 100 Emlen Way, Suite # 104-108, Telford, PA-18969, USA.
  • Haware RV; Natoli Scientific, A Division of Natoli Engineering Company, Inc., 100 Emlen Way, Suite # 104-108, Telford, PA-18969, USA. rhaware@natoli.com.
Pharm Res ; 40(12): 2935-2945, 2023 Dec.
Article in En | MEDLINE | ID: mdl-37380906
ABSTRACT

PURPOSE:

Increased tablet anisotropy could lead to increased tablet capping propensity. Tooling design variables such as cup depth could serve as a key player for inducing tablet anisotropy.

METHODS:

A new capping index (CI) consisting of the ratio of compact anisotropic index (CAI) and material anisotropic index (MAI) is proposed to evaluate tablet capping propensity as a function of punch cup depth. CAI is the ratio of axial to radial breaking force. MAI is the ratio of axial to radial Young's modulus. The impact of various punch cup depths [flat face, flat face beveled edge, flat face radius edge, standard concave, shallow concave, compound concave, deep concave, and extra deep concave] on the capping propensity of model acetaminophen tablets was studied. Tablets were manufactured at 50, 100, 200, 250, and 300 MPa compression pressure at 20 RPM on different cup depth tools using Natoli NP-RD30 tablet press. A partial least squares model (PLS) was computed to model the impact of the cup depth and compression parameters on the CI.

RESULTS:

The PLS model exhibited a positive correlation of increased cup depth to the capping index. The finite elemental analysis confirmed that a high capping tendency with increased cup depth is a direct result of non-uniform stress distribution across powder bed.

CONCLUSIONS:

Certainly, a proposed new capping index with multivariate statistical analysis gives guidance in selecting tool design and compression parameters for robust tablets.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mechanical Phenomena / Acetaminophen Type of study: Prognostic_studies Language: En Journal: Pharm Res Year: 2023 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mechanical Phenomena / Acetaminophen Type of study: Prognostic_studies Language: En Journal: Pharm Res Year: 2023 Type: Article Affiliation country: United States