Your browser doesn't support javascript.
loading
A metal-organic framework-based fluorescence resonance energy transfer nanoprobe for highly selective detection of Staphylococcus Aureus.
Qiao, Jing; Chen, Xuanbo; Xu, Xingliang; Fan, Ben; Guan, Ying-Shi; Yang, Hong; Li, Quan.
Affiliation
  • Qiao J; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
  • Chen X; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
  • Xu X; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
  • Fan B; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
  • Guan YS; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
  • Yang H; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
  • Li Q; Institute of Advanced Materials and School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. gyshi412@seu.edu.cn.
J Mater Chem B ; 11(35): 8519-8527, 2023 09 13.
Article in En | MEDLINE | ID: mdl-37606203
Survival and infection of pathogenic bacteria, such as Staphylococcus aureus (S. aureus), pose a serious threat to human health. Efficient methods for recognizing and quantifying low levels of bacteria are imperiously needed. Herein, we introduce a metal-organic framework (MOF)-based fluorescence resonance energy transfer (FRET) nanoprobe for ratiometric detection of S. aureus. The nanoprobe utilizes blue-emitting 7-hydroxycoumarin-4-acetic acid (HCAA) encapsulated inside zirconium (Zr)-based MOFs as the energy donor and green-emitting fluorescein isothiocyanate (FITC) as the energy acceptor. Especially, vancomycin (VAN) is employed as the recognition moiety to bind to the cell wall of S. aureus, leading to the disassembly of VAN-PEG-FITC from MOF HCAA@UiO-66. As the distance between the donor and acceptor increases, the donor signal correspondingly increases as the FRET signal decreases. By calculating the fluorescence intensity ratio, S. aureus can be quantified with a dynamic range of 1.05 × 103-1.05 × 107 CFU mL-1 and a detection limit of 12 CFU mL-1. Due to the unique high affinity of VAN to S. aureus, the nanoprobe shows high selectivity and sensitivity to S. aureus, even in real samples like lake water, orange juice, and saliva. The FRET-based ratiometric fluorescence bacterial detection method demonstrated in this work has a prospect in portable application and may reduce the potential threat of pathogens to human health.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Staphylococcal Infections / Metal-Organic Frameworks Type of study: Diagnostic_studies Limits: Humans Language: En Journal: J Mater Chem B Year: 2023 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Staphylococcal Infections / Metal-Organic Frameworks Type of study: Diagnostic_studies Limits: Humans Language: En Journal: J Mater Chem B Year: 2023 Type: Article Affiliation country: China