Your browser doesn't support javascript.
loading
Lung ultrasound-guided best positive end-expiratory pressure in neonatal anesthesia: a proposed randomized, controlled study.
Camporesi, Anna; Pierucci, Ugo Maria; Paladini, Giuseppe; Gentile, Andrea; Buonsenso, Danilo; Pelizzo, Gloria.
Affiliation
  • Camporesi A; Department of Pediatric Anesthesia and Intensive Care, Buzzi Children's Hospital, Milan, Italy. anna.camporesi@gmail.com.
  • Pierucci UM; Pediatric Surgery Department, Buzzi Children's Hospital, Milan, Italy.
  • Paladini G; Department of Pediatric Anesthesia and Intensive Care, Buzzi Children's Hospital, Milan, Italy.
  • Gentile A; Department of Medical-Surgical Physiopathology and Transplants, University of Milan, Milan, Italy.
  • Buonsenso D; Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "A. Gemelli", Roma, Italy.
  • Pelizzo G; Pediatric Surgery Department, Buzzi Children's Hospital, Milan, Italy.
Pediatr Res ; 95(1): 393-396, 2024 Jan.
Article in En | MEDLINE | ID: mdl-37648746
ABSTRACT

BACKGROUND:

Atelectasis is a common complication in neonatal anesthesia. Lung ultrasound (LUS) can be used intraoperatively to evaluate and recognize atelectatic lung areas. Hypotheses for the study are (1) The use of LUS to guide choice of best positive end-expiratory pressure (PEEP) can lead to reduction of FiO2 to achieve same saturations of oxygen (SpO2). (2) In a less de-recruited lung, there will be less postoperative pulmonary complications. (3) Static respiratory system compliance could be different. (4) Hemodynamic parameters and amount of fluids infused or need for vasopressors intraoperatively could be different.

METHODS:

We propose a randomized controlled trial that compares standard PEEP settings with LUS-guided PEEP choice in patients under 2 months of age undergoing general anesthesia.

RESULTS:

The primary aim is to determine whether LUS-guided PEEP choice in neonatal anesthesia, compared to standard PEEP choice, can lead to reduction of FiO2 applied to the ventilatory setting in order to maintain same SpO2s. Secondary aims are to determine whether patients treated with LUS-guided PEEP will develop less postoperative pulmonary complications, will have a significant difference in hemodynamic parameters and amount of fluids or vasopressors infused, and in static respiratory system compliance.

CONCLUSIONS:

We expect a significant reduction of FiO2 in LUS-guided ventilation. IMPACT Lung atelectasis is extremely common in neonatal anesthesia, because of the physiology of the neonatal lung and chest wall and leads to hypoxemia, being a lung area with a perfusion/ventilation mismatch. Raising inspired fraction of oxygen can overcome temporarily hypoxemia but oxygen is a toxic compound for newborns. Lung ultrasound (LUS) can detect atelectasis at bedside and be used to optimize ventilator settings including choice of positive end-expiratory pressure (PEEP). This randomized controlled trial (RCT) aims at demonstrating that LUS-guided choice of best PEEP during neonatal anesthesia can lead to reduction of inspired fractions of oxygen to keep same peripheral saturations SpO2.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pulmonary Atelectasis / Lung Type of study: Clinical_trials Limits: Humans / Newborn Language: En Journal: Pediatr Res Year: 2024 Type: Article Affiliation country: Italy