Intracanal removal and apical extrusion of filling material after retreatment using rotary or reciprocating instruments: A new approach using human cadavers.
Monteiro, Thamyres M; Cortes-Cid, Victor O; Marceliano-Alves, Marilia F V; Campello, Andrea F; Bastos, Luan F; Lopes, Ricardo T; Siqueira, José F; Alves, Flávio R F.
Affiliation
  • Monteiro TM; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Duque de Caxias, Brazil.
  • Cortes-Cid VO; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Duque de Caxias, Brazil.
  • Marceliano-Alves MFV; Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, Brazil.
  • Campello AF; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Duque de Caxias, Brazil.
  • Bastos LF; Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, Brazil.
  • Lopes RT; Department of Nuclear Energy, Rio de Janeiro Federal University, Rio de Janeiro, Brazil.
  • Siqueira JF; Department of Nuclear Energy, Rio de Janeiro Federal University, Rio de Janeiro, Brazil.
  • Alves FRF; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Duque de Caxias, Brazil.
Int Endod J ; 57(1): 100-107, 2024 Jan.
Article in En | MEDLINE | ID: mdl-37886883
ABSTRACT

AIM:

This study compared intracanal removal of filling as well as the frequency and volume of extruded material after retreatment with either HyFlex or Reciproc instruments in mandibular teeth from cadavers.

METHODOLOGY:

The root canals of 14 pairs of contralateral single-rooted teeth in mandibles of cadavers were instrumented with Reciproc R40 and filled using lateral compaction. The mandibles were scanned in a micro-computed tomographic (micro-CT) device before and after retreatment procedures. The contralateral teeth were assigned to two groups (n = 14) according to the retreatment protocol using either HyFlex or Reciproc instrument systems. In the HyFlex group, the HyFlex Remover instrument was worked 3 mm short of the working length (WL), followed by HyFlex CM 40.04 and 50.04 at the WL. In the Reciproc group, the R50 instrument was worked up at the coronal two thirds, followed by two more cycles until the WL was reached. Pre- and post-operative micro-CT images were analysed for extrusion and intracanal removal of filling material.

RESULTS:

After retreatment, extrusion of filling material occurred in 11 (78%) and 14 (100%) teeth from HyFlex and Reciproc groups respectively (p > .05). A similar volume of extruded material was observed after retreatment with both systems (p > .05). A significant decrease in the intracanal filling volume was verified after retreatment with both tested systems (p < .05). However, residual filling material was found in all root canals, regardless of the system. The amount of filling material removed (HyFlex = 80.8%; Reciproc = 65.9%) and the operation time was similar between systems (p > .05).

CONCLUSIONS:

A high frequency of filling material extrusion was observed after retreatment with the two systems in a cadaver model, with no significant difference between them. Both protocols obtained similar efficacy in filling material removal procedures, although none completely cleaned the canals.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Root Canal Filling Materials Limits: Humans Language: En Journal: Int Endod J Year: 2024 Type: Article Affiliation country: Brazil