Your browser doesn't support javascript.
loading
Autonomous Needle Navigation in Retinal Microsurgery: Evaluation in ex vivo Porcine Eyes.
Zhang, Peiyao; Kim, Ji Woong; Gehlbach, Peter; Iordachita, Iulian; Kobilarov, Marin.
Affiliation
  • Zhang P; Department of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21211, USA.
  • Kim JW; Department of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21211, USA.
  • Gehlbach P; Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD 21211, USA.
  • Iordachita I; Department of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21211, USA.
  • Kobilarov M; Department of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21211, USA.
IEEE Int Conf Robot Autom ; 2023: 4661-4667, 2023.
Article in En | MEDLINE | ID: mdl-38107423
ABSTRACT
Important challenges in retinal microsurgery include prolonged operating time, inadequate force feedback, and poor depth perception due to a constrained top-down view of the surgery. The introduction of robot-assisted technology could potentially deal with such challenges and improve the surgeon's performance. Motivated by such challenges, this work develops a strategy for autonomous needle navigation in retinal microsurgery aiming to achieve precise manipulation, reduced end-to-end surgery time, and enhanced safety. This is accomplished through real-time geometry estimation and chance-constrained Model Predictive Control (MPC) resulting in high positional accuracy while keeping scleral forces within a safe level. The robotic system is validated using both open-sky and intact (with lens and partial vitreous removal) ex vivo porcine eyes. The experimental results demonstrate that the generation of safe control trajectories is robust to small motions associated with head drift. The mean navigation time and scleral force for MPC navigation experiments are 7.208 s and 11.97 mN, which can be considered efficient and well within acceptable safe limits. The resulting mean errors along lateral directions of the retina are below 0.06 mm, which is below the typical hand tremor amplitude in retinal microsurgery.