Temporarily Reversing Warfarin With Low-Dose 4-Factor Prothrombin Complex Concentrate in Left Ventricular Assist Device Patients Undergoing an Invasive Procedure.
Stevenson, Byron; Roberts, A Joshua; Dager, William E.
Affiliation
  • Stevenson B; Davis Medical Center, University of California, Sacramento, CA, USA.
  • Roberts AJ; Davis Medical Center, University of California, Sacramento, CA, USA.
  • Dager WE; Davis Medical Center, University of California, Sacramento, CA, USA.
Ann Pharmacother ; : 10600280241248172, 2024 Apr 27.
Article in En | MEDLINE | ID: mdl-38678311
ABSTRACT

BACKGROUND:

American Association for Thoracic Surgery and The International Society for Heart and Lung Transplantation (AATS/ISHLT) guidelines recommend warfarin in patients with continuous-flow left ventricular assist devices (LVADs) to reduce the risk of device thrombosis and systemic embolization. Left ventricular assist device patients often undergo elective and emergent procedures that require interrupted anticoagulation. Data and experience vary on the optimal strategy to rapidly reverse warfarin in LVAD patients when an emergent procedure is planned.

OBJECTIVE:

The purpose of this study was to describe the use of 4-factor prothrombin complex concentrate (PCC4) for warfarin reversal in patients with LVADs undergoing elective and emergent procedures.

METHODS:

This retrospective, single-center, cohort review describes the use of PCC4 in patients with LVADs who require warfarin reversal for elective or emergent procedures. The primary outcome was a composite incidence of pump thrombosis, venous thromboembolism, and ischemic stroke within 30 days of PCC4 administration.

RESULTS:

In total, 14 patients received 17 administrations of PCC4. One patient received 3 administrations, and 1 other patient received 2 administrations during separate encounters. The median dose was 500 units or 6.6 units/kg (range = 4.2-14.1 units/kg). Of the PCC4 administrations, 82% (14/17) were for low bleed risk procedures and 76% (13/17) were for elective procedures. There were no cases of pump thrombosis, venous thromboembolism, or stroke within 30 days of the procedure. CONCLUSIONS AND RELEVANCE Low-dose PCC4 appears to be a safe and effective temporary reversal strategy for patients with LVADs undergoing low-bleed risk elective procedures.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Ann Pharmacother Journal subject: FARMACOLOGIA / TERAPIA POR MEDICAMENTOS Year: 2024 Type: Article Affiliation country: United States