Your browser doesn't support javascript.
loading
A mesothelin microsensor based on an embedded thionine electronic medium within an imprinted polymer on an acupuncture needle electrode.
Zhang, Yi; Kong, Xue; Guo, Hai-Yang; Wang, Jing; Yin, Zheng-Zhi.
Affiliation
  • Zhang Y; College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China. Jingw1986@zjut.edu.cn.
  • Kong X; College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China. yinzhengzhi@zjxu.edu.cn.
  • Guo HY; Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001. China.
  • Wang J; College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China. Jingw1986@zjut.edu.cn.
  • Yin ZZ; College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China. yinzhengzhi@zjxu.edu.cn.
Analyst ; 149(12): 3309-3316, 2024 Jun 10.
Article in En | MEDLINE | ID: mdl-38699925
ABSTRACT
An electrochemical microsensor for mesothelin (MSLN) based on an acupuncture needle (AN) was constructed in this work. To prepare the microsensor, MSLN was self-assembled on 4-mercaptophenylboronic acid (4-MPBA) by an interaction force between the external cis-diol and phenylboronic acid. This was followed by the gradual electropolymerization of thionine (TH) and eriochrome black T (EBT) around the anchored protein. The thickness of the surface imprinted layers influenced the sensing performance and needed to be smaller than the height of the anchored protein. The polymerized EBT was not electrically active, but the polymerized TH provided a significant electrochemical signal. Therefore, electron transfer smoothly proceeded through the eluted nanocavities. The imprinted nanocavities were highly selective toward MSLN, and the rebinding of insulating proteins reduced the electrochemical signal of the embedded pTH. The functionalized interface was characterized by SEM and electrochemical methods, and the preparation conditions were studied. After optimization, the sensor showed a linear response in the range of 0.1 to 1000 ng mL-1 with a detection limit of 10 pg mL-1, indicating good performance compared with other reported methods. This microsensor also showed high sensitivity and stability, which can be attributed to the fine complementation of the imprinted organic nanocavities. The sensitivity of this sensor was related to the nanocavities used for electron transport around the AuNPs. In the future, microsensors that can directly provide electrochemical signals are expected to play important roles especially on AN matrices.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phenothiazines / Biosensing Techniques / Electrodes / Electrochemical Techniques / Limit of Detection / Mesothelin Limits: Humans Language: En Journal: Analyst Year: 2024 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phenothiazines / Biosensing Techniques / Electrodes / Electrochemical Techniques / Limit of Detection / Mesothelin Limits: Humans Language: En Journal: Analyst Year: 2024 Type: Article Affiliation country: China